532737
12
Zoom out
Zoom in
Vorherige Seite
1/30
Nächste Seite
4
1
DESCRIPTION
This lifting station is (manufactured in a
factory which is quality) certified to ISO
9001. Installed and used correctly, the unit
will give consistent and reliable service.
This device is not designed for
persons (including child-
ren) with limited physical, sensory
or mental abilities, or those with
minimal experience and knowledge,
unless they are monitored and are
given the necessary instructions for
using the device, with the help of a
person responsible for their safety.
Monitor children and make sure they
do not play with the device.
2
APPLICATIONS
This device is a compact lifting sta-
tion designed to evacuate waste water
from private dwellings (except for water
coming from WC's).
SANIVITE
®
, SANISPEED
®
and SANIPUMP
2
®
are designed to handle the waste eva-
cuation from a bath domestic kitchen sink,
dishwasher and washing machine - all
working at the same time if required. Its
powerful pump will deal with every day nor-
mal usage. SANISHOWER® FLAT/ SANI-
DOUCHE® FLAT is designed to handle the
waste from a shower only.
Sanispeed will take the above at a heavier
duty rate of usage.
SANISHOWER
®
/SANIPUMP 1
®
is desig-
ned to take the waste from a shower and
handbasin.
This appliance conforms to EN 12050-3
and the European standards concerning
electrical safety and electromagnetic
compatibility.
3
INSTALLATION
The unit should be installed in the same
space as the connected facilities and
should be accessible for possible service.
The fitting and working of your appliance
must meet local regulations and the EN
12056-4 standard.
To optimise the latest technical deve-
lopments concerning soundproofing
incorporated into this unit, it is impor-
tant to:
slXTHEDISCHARGEPIPECORRECTLYWITH
distances of not more than one metre
between the fastenings.
CONNECTION TO THE ELECTRICAL
SUPPLY
The electrical installation
should be carried out by a quali-
fied person.
The unit should be connected to a fully
earthed electrical supply. All wiring must
CONFORM TO "3  REQUIREMENTS
for electrical installations. The unit requires
a 220/240V single phase AC 50 Hz supply
(UK specification). Do not connect the unit to
a conventional plug and socket. It must be
wired into a fused, unswitched, fixed
wiring connector fitted with a 5 amp
fuse. The wires in the mains lead are colou-
red in accordance with the following code:
"ROWN,IVE
"LUE.EUTRAL
'REEN9ELLOWn%ARTH
Warning: Ensure the electricity is
turned OFF at the main switch board
before wiring to connector.
All work on cable, pressure chamber
and motor should only be carried out
4
COMMISSIONING THE
UNIT
Once electrical and plumbing connections
have been made, check that all seals, and
connections are watertight.
Check both the discharge pipework from
the unit and the other sanitary appliances
connections.
5
MAINTENANCE
WARNING !!!
If away for a long period, we recommend
that you turn off the water supply to the
WC served by the unit.
CARE OF YOUR UNIT
In order to remove scale and clean the
lifting station, use a household descalent
(like SANIFLO Cleanser/descalent).
6
FAULT FINDING / REMEDIES
SYMPTOMS PROBABLE CAUSES REMEDIES
s4HEMOTORDOESNOTACTIVATE s4HEELECTRICALPOWERSUPPLY
ISNOTACTIVE
s4HEELECTRICALPOWERSUPPLYIS
DEFECTIVE
s4HEMOTORORTHECONTROLSYSTEM
ISDEFECTIVE
s2ESTORETHEELECTRICALSUPPLY
s#HECKTHEELECTRICALPOWER
supply
s/THERWISEASKANAPPROVED
repair agent to intervene
s4HEMOTORINTERMITTENTLY
activates
s4HECONNECTEDSANITARYDEVICES
ARELEAKING
s4HENONRETURNVALVEISFAULTY
s#HECKTHEINSTALLATIONUPSTREAM
s#LEANORREPLACETHENONRETURN
valve
s4HEMOTOROPERATESNORMALLYBUT
continues to run for a long time
s4HELENGTHORHEIGHTOFTHE
INSTALLATIONISOVERTHE
SPECIlCATIONORTHEREARETOO
MANYBENDSELBOWS
s4HELIFTINGSTATIONCOVERPLATEIS
OCCLUDED
s#HECKTHEINSTALLATION
s/THERWISEASKANAPPROVED
repair agent to intervene
s4HEUNITSTOPS s4HEUNITHASBEENRUNNINGFOR
TOOLONGTHERMALCUTOUT
s7AITFORRESETTHENASKAN
approved repair agent to
intervene
s#LOUDYWATERCOMESUPINTO
the shower basin (units with
side inlets)
s3HOWERINSTALLEDTOOLOWAS
COMPAREDWITHTHELIFTINGSTATION
s(INGEDSIDEINLETDISCS
CLOGGEDUP
s#HECKTHEINSTALLATION
s#LEANTHEHINGEDDISCS
s/THERWISEASKANAPPROVED
repair agent to intervene
IN ALL CASES, YOU MUST DISCONNECT
THE MACERATOR FROM THE POWER SUPPLY
7
GUARANTEE
2 years guarantee as from its date of purchase subject to correct installation and correct use.
Warning : Do not dispose of solvents, paints (do not wash paint brushes in sink), caustic,
acid or other chemicals into these products.
by a qualified Saniflo servicing agent,
as special tools are required.
UK
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

sanibroyeur-traymatic-intern

Suche zurücksetzen

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sanibroyeur TRAYMATIC Intern wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info