Chapter 4Settings — [PROJECTOR SETUP] menu
ENGLISH - 143
3) Press qw to switch the pages.
f The page will change each time you press the button.
[PROJECTOR TYPE] Displays the projector type and serial number of the projector.
[PROJECTOR RUNTIME] Displays the runtime of the projector.
[LIGHT RUNTIME] Displays the runtime of the light source 1 and the light source 2.
[MAIN/SUB VERSION] Displays the main and sub versions of the rmware of the projector.
[INTAKE AIR TEMP.]
*1
Displays the status of the intake air temperature of the projector.
[OPTICS MODULE TEMP.]
*1
Displays the status of the internal temperature of the projector.
[EXHAUST AIR TEMP.]
*1
Displays the status of the exhaust air temperature of the projector.
[AROUND LIGHT1 TEMP.]
*1
Displays the status of the temperature around light source 1 of the projector.
[AROUND LIGHT2 TEMP.]
*1
Displays the status of the temperature around light source 2 of the projector.
[COOLING CONDITION] Displays the set cooling conditions. Automatically recognized result is displayed when set to [AUTO].
[ATMOSPHERIC PRESSURE] Displays the atmospheric pressure.
[SELF TEST] Displays the status of the projector.
[INPUT] Displays the input terminal currently selected.
[BACKUP INPUT STATUS]
Displays whether switching to the backup input signal is possible or not when [BACKUP INPUT
MODE] is set to [OFF]. (x page 110)
[SIGNAL NAME] Displays the input signal name.
[SIGNAL FREQUENCY] Displays the frequency of the input signal.
[NUMBER OF REGISTERED
SIGNAL]
Displays the number of registered signals.
[REMOTE2 STATUS] Displays the control status of the REMOTE2.
[AC VOLTAGE] Displays the input supply voltage.
[UPGRADE]
[ET-UK20]
Displays the activation status by the Upgrade Kit (Model No.:
ET-UK20).
[ET-CUK10]
Displays the activation status by the Auto Screen Adjustment
Upgrade Kit (Model No.: ET-CUK10).
[ON COUNT]
[POWER ON TIMES] Displays the number of times the power is turned on.
[SHUTTER]
Displays the number of times the mechanical shutter is closed.
It is counted when [MECHANICAL SHUTTER] is set to [ENABLE].
[SIGNAL INFORMATION]
[MEMORY NO.] Displays the memory number of the input signal.
[INPUT] Displays the input terminal currently selected.
[SIGNAL NAME] Displays the input signal name.
[SIGNAL FREQUENCY] Displays the frequency of the input signal.
[SYNC.STATE] Displays the synch polarity of the input signal.
[V.SYNC WIDTH] Displays the vertical sync signal pulse width of the input signal.
[SCAN TYPE] Displays the scan type of the input signal.
[TOTAL DOTS] Displays the total dot count of the input signal.
[DISPLAY DOTS] Displays the number of input signal display dots.
[TOTAL LINES] Displays the total line count of the input signal.
[DISPLAY LINES] Displays the number of input signal display lines.
[SAMPLING] Displays the sampling information of the input signal.
[SIGNAL LEVEL] Displays the signal level of the input signal.
[BIT DEPTH] Displays the gradation of the input signal.
*1 The temperature status is indicated with text color (green/yellow/red) and bar scale. Use the projector within the range that the indication is
green.
Note
f Press the <ENTER> button while displaying the [STATUS] screen to send an E-mail including the content of status to the E-mail addresses
(up to two addresses) set in “[E-mail set up] page” (x page 172).
f Some items in [SIGNAL INFORMATION] may be displayed and others not displayed, depending on the signal being input.
f If any abnormality has occurred on the projector, press the <DEFAULT> button while the [STATUS] screen is displayed to display the detail
screen of the error information.
f For details on the contents displayed in [SELF TEST], refer to “Self-diagnosis display” (x page 189).
[AC VOLTAGE MONITOR]
Enable or disable the AC voltage monitor function. The value of input supply voltage is displayed on the self-
diagnosis display at the side of the projector when enabled.
1) Press as to select [AC VOLTAGE MONITOR].
143

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sanyo PT-RS11K wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Sanyo PT-RS11K

Sanyo PT-RS11K Bedienungsanleitung - Deutsch - 223 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info