Every 15 minutes, the detector sends a transmission with information on the current status of
the reed switch, tamper contact and battery. Periodic transmissions are used to monitor
presence and operation of the magnetic contact.
Note: In the case of the AMD-103 magnetic contact, the presence check is performed in
a different way than for the other ABAX system devices. If the value programmed for
the F
ILTER
parameter differs from 0, the lack of presence will be reported if no
transmission from the detector is received within one hour.
The LED is only working in the test mode:
it is lit for 80 milliseconds, when the test transmission is being sent;
it is lit for 2 seconds in the event of alarm.
The test mode is turned on for 20 minutes after inserting the batteries or opening the tamper
contact.
The detector checks the battery status. When the voltage is lower than 2.6 V, the low-battery
information is sent during each transmission.
4. Installation
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
The device is designed for indoor installation. The detector should be mounted on a fixed
surface (e.g. window or door frame), and the magnet on a movable surface (e.g. window or
door). Mounting the magnetic contact on ferromagnetic surfaces and/or near to strong
magnetic and electrical fields is not advisable, because it can result in malfunctioning of the
device.
Special designation on the detector enclosure indicates the side on which the magnets
should be installed (Fig. 6).
1. Open the detector enclosure (Fig. 2).
2. Install the battery and add the device to the wireless system (see the ACU-100 / ACU-250 /
ACU-120 / ACU-270 controller manual, installer manuals for INTEGRA 128-WRL or
VERSA control panels).
3. Close the detector enclosure (the tamper contact must be pressed down by the base
element).
4. Fasten the detector temporarily at the place of its future installation.
5. Move the magnet away from the detector. The detector will send information on the alarm,
which will allow you to check the level of signal received from the detector by the
ACU-100 / ACU-250 / ACU-120 / ACU-270 controller or the INTEGRA 128-WRL control
panel. If necessary, select another place for installation, to ensure adequate
communication quality.
6. Open the detector enclosure (Fig. 2).
7. Using wall plugs (screw anchors) and screws, fasten the enclosure base to the mounting
surface (Fig. 3).
8. Close the detector enclosure (the tamper contact must be pressed down by the base
element).
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel AMD-103 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel AMD-103

Satel AMD-103 Bedienungsanleitung - Deutsch - 4 seiten

Satel AMD-103 Bedienungsanleitung - Holländisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info