10 AXD-200 SATEL
3. Knock once on the detector enclosure to select next type as shown in Table 2. The next
type after the water flood detector (7 flashes) is the magnetic contact (1 flash).
4. Wait until the LED flashes once and then indicates the type that has been selected. You
can only select next type when the LED stops flashing.
5. Repeat the steps 3 and 4 until you select the appropriate type of detector.
6. Wait about 10 seconds. After that time the LED will inform you what type has been saved
to the detector memory.
Do not close the detector enclosure before saving the type to the detector memory.
Otherwise, it can be interpreted by the detector as another knock on the enclosure,
which will change the type selected.
4 Specifications
Operating frequency band................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area)
ABAX 2
ACU-220 ..............................................................................................up to 2000 m
ACU-280 ..............................................................................................up to 1200 m
ABAX..............................................................................................................up to 500 m
Battery.................................................................................................................... CR123A 3 V
Battery life expectancy.......................................................................................... up to 2 years
NC type input sensitivity................................................................................................. 240 ms
Temperature measurement range .......................................................................-10°C...+55°C
Temperature measurement accuracy ................................................................................ ±1°C
Standby current consumption .......................................................................................... 20 µA
Maximum current consumption ......................................................................................... 7 mA
Complied with standards....... EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-2-6, EN 50131-5-3
Security grade according to EN50131-2-6 .................................................................... Grade 2
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range...............................................................................-10°C...+55°C
Maximum humidity ..........................................................................................................93±3%
Enclosure dimensions ................................................................................... 20 x 102 x 23 mm
Surface mounted magnet enclosure dimensions .............................................. 15 x 52 x 6 mm
Surface mounted magnet spacer dimensions ................................................... 15 x 52 x 6 mm
Flush mounted magnet enclosure dimensions...................................................... ø10 x 28 mm
Weight................................................................................................................................. 59 g
Magnetic contact
Gap (max.):
surface magnet ..............................................................................................20 mm
flush magnet................................................................................................... 18 mm
Shock detector
Detection range (depending on the surface type) ....................................................... up to 3 m
The specified detection range should be considered approximate. The actual range
should be determined experimentally after securing the detector to the surface.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel AXD-200 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel AXD-200

Satel AXD-200 Bedienungsanleitung - Deutsch - 13 seiten

Satel AXD-200 Bedienungsanleitung - Holländisch - 13 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info