22 PERFECTA LTE SATEL
7.2 Numeration of outputs
7.2.1 Hardwired outputs
The outputs on control panel main board have numbers from 1 to 4.
The outputs in expander have numbers from 5 to 12.
7.2.2 Wireless outputs PERFECTA 32-WRL LTE
The wireless outputs have numbers from 13 to 16.
8. Specifications
8.1 Control panel
Supply voltage ....................................................................................18 VAC ±15%, 50-60 Hz
Recommended transformer ............................................................................................. 40 VA
Standby current consumption
PERFECTA 32 LTE......................................................................170 mA
PERFECTA 32-WRL LTE ............................................................240 mA
Maximum current consumption
PERFECTA 32 LTE......................................................................570 mA
PERFECTA 32-WRL LTE ............................................................630 mA
Standby current consumption from battery
PERFECTA 32 LTE......................................................................130 mA
PERFECTA 32-WRL LTE ............................................................150 mA
Maximum current consumption from battery
PERFECTA 32 LTE......................................................................430 mA
PERFECTA 32-WRL LTE ............................................................450 mA
Power supply output voltage ............................................................................... 12 VDC ±15%
Power supply output voltage range.....................................................................10.5…14 VDC
Power supply output current ................................................................................................ 2 A
Battery charging current.................................................................................................500 mA
Battery failure voltage threshold............................................................................... 11 V ±10%
Battery cut-off voltage ........................................................................................... 10.5 V ±10%
High-current programmable outputs ............................................................ 1000 mA / 12 VDC
Low-current programmable outputs ................................................................. 25 mA / 12 VDC
KPD output..................................................................................................... 500 mA / 12 VDC
AUX output..................................................................................................... 500 mA / 12 VDC
Hardwired programmable zones ..............................................................................................8
Maximum number of programmable zones............................................................................32
Hardwired programmable outputs............................................................................................4
Maximum number of programmable outputs
PERFECTA 32 LTE..............................................................................12
PERFECTA 32-WRL LTE ....................................................................16
Power supply outputs...............................................................................................................2
Communication buses..............................................................................................................1
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel PERFECTA 32 LTE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel PERFECTA 32 LTE

Satel PERFECTA 32 LTE Bedienungsanleitung - Deutsch - 11 seiten

Satel PERFECTA 32 LTE Zusatzinformation - Deutsch - 50 seiten

Satel PERFECTA 32 LTE Installationsanweisung - Deutsch - 27 seiten

Satel PERFECTA 32 LTE Kurzanleitung - Englisch - 10 seiten

Satel PERFECTA 32 LTE Bedienungsanleitung - Englisch - 30 seiten

Satel PERFECTA 32 LTE Zusatzinformation - Englisch - 47 seiten

Satel PERFECTA 32 LTE Zusatzinformation - Englisch - 50 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info