Battery failure voltage threshold............................................................................... 11 V ±10%
Battery cut-off voltage ........................................................................................... 10.5 V ±10%
Battery charging current.................................................................................................800 mA
Power supply output current ................................................................................................ 2 A
Power supply output voltage .............................................................................. 12 V DC ±15%
Power supply output voltage range................................................................ 10.5 V…14 V DC
High-current programmable outputs ............................................................ 1100 mA / 12 VDC
Low-current programmable outputs ................................................................. 50 mA / 12 VDC
Relay output................................................................................................. 1000 mA / 24 VDC
KPD output.................................................................................................... 500 mA / 12 V DC
AUX output.................................................................................................... 500 mA / 12 V DC
+VR output.................................................................................................... 200 mA / 12 V DC
Hardwired programmable zones ..............................................................................................4
Maximum number of programmable zones............................................................................30
Hardwired programmable outputs............................................................................................5
Maximum number of programmable outputs.......................................................................... 12
Power supply outputs...............................................................................................................3
Communication buses..............................................................................................................1
Keypads ..........................................................................................................................up to 6
Partitions ..................................................................................................................................2
Telephone numbers for messaging..........................................................................................8
Voice messages.....................................................................................................................16
Text messages.......................................................................................................................64
Email addresses for messaging ...............................................................................................8
Users......................................................................................................................................30
Timers ......................................................................................................................................4
Event log ............................................................................................................................2047
Security grade according to EN50131 ..........................................................................Grade 2
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range................................................................................. -10…+55 °C
Maximum humidity ..........................................................................................................93±3%
Electronics board dimensions ............................................................................. 173 x 105 mm
Enclosure dimensions ............................................................................... 266 x 286 x 100 mm
Weight (incl. enclosure and accessories)........................................................................1250 g
7.2 VERSA-LCD keypad
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption VERSA-LCD-GR ..................................36 mA
VERSA-LCD-BL ...................................40 mA
Maximum current consumption VERSA-LCD-GR................................110 mA
VERSA-LCD-BL .................................130 mA
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range................................................................................. -10…+55 °C
Maximum humidity ..........................................................................................................93±3%
Enclosure dimensions............................................................................. 114.5 x 95 x 22.5 mm
Weight...............................................................................................................................123 g
34

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Satel Versa Plus wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Satel Versa Plus

Satel Versa Plus Kurzanleitung - Deutsch - 12 seiten

Satel Versa Plus Zusatzinformation - Deutsch - 113 seiten

Satel Versa Plus Bedienungsanleitung - Deutsch - 46 seiten

Satel Versa Plus Installationsanweisung - Deutsch - 36 seiten

Satel Versa Plus Bedienungsanleitung - Englisch - 44 seiten

Satel Versa Plus Zusatzinformation - Englisch - 110 seiten

Satel Versa Plus Kurzanleitung - Englisch - 11 seiten

Satel Versa Plus Installationsanweisung - Englisch - 32 seiten

Satel Versa Plus Kurzanleitung - Holländisch - 11 seiten

Satel Versa Plus Bedienungsanleitung - Holländisch - 46 seiten

Satel Versa Plus Zusatzinformation - Holländisch - 110 seiten

Satel Versa Plus Zusatzinformation - Holländisch - 2 seiten

Satel Versa Plus Installationsanweisung - Holländisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info