6
INSTALLATION
Before installing the water-heater, the water
pipework must be flusched out to ensure that there
is no foreign matter present that could damage the
heater.
NOTE : do not use solvent products.
● Using the template supplied, fasten the hanging
bracket onto the wall.
● Hang the water heater onto the hanging bracket.
●
Connect the pipework and fittings, supplied, to
the gas inlet, cold water inlet and hot water outlet,
see diagrams.
ELECTRIC POWER SUPPLY
Warning : the power supply cable built into the
water-heater is specific to it. If you wish to replace
it, please order a new one quoting part number
59114 from an approved Saunier Duval dealer.
● Connect the water-heater power supply cable to
the 230V mains supply. Ensure that the live and
neutral are connected correctly. To comply with
current standards, this connector must be made
through a double-pole switch with a contact
separation of no less than 3 mm.
FLUE LOCATION
Minimum dimensions (in mm)
for the positioning of flue terminals
N
C
D
M
A
B
E
F
G
I
H
L
Ven 060b
A-Under a window ................................................. 600
B-Under an air vent ................................................ 600
C-Under a gutter ..................................................... 300
D-Under a balcony ................................................. 300
E-From an adjacent window ................................ 400
F-From an adjacent air vent................................. 600
G-From vertical or horizontal air pipes ................... 600
H-From an external corner of the building .......... 300
I-From an internal corner of the building ......... 1000
L-From the ground or from another floor .......... 1800
M-Between two terminals vertically .................... 1500
N-Between two terminals horizontally .................. 600
A
C B
Des 073
AC B
Ins 053a
Pla 188
Water
mechanism
filter
B
gasket
flow rate
limiter
cold water isolating
valve
A - Gas inlet
B - Cold water inlet
C - Hot water outlet
cold water inlet