piece from tipping or slipping away.
use the push stick.
position and guide the workpiece on the fence.
the saw bench to the plus or minus position. Insure safe
workpiece guidance.
workpiece with your hands on a safe area.
round pieces.
traverse cutting gauge special accessory for safety
when making traverse cuts.
circular cutting unit
special accessory.
Maintenance
mPerform resetting, measuring, and cleaning work
exclusively when the motor is turned off. Disconnect
the main power supply, and wait until the rotating tool stands
still.
All protection and safety devices must be immediately rein-
stalled once the repair and maintenance work is completed.
The built-in ball bearings are maintenance-free.
Recommendations:
and the bend tensioning device.
2. Regularly clean the saw band. Wood leaves resin sedi-
ments. We recommend the deresinifying concentrate
3. Regularly check the guiding rollers and the counterpres-
sure bearings. If required, readjust or disassemble them,
and grease or exchange the parts.
5. Ensure that the tabletop is always free of resin.
6.
Regularly lubricate the bearings of the speed handwheel.
Electrical Connection
mThe installed electric motor
is connected and is ready to work.
The connection complies with the relevant VDE and DIN
regulations.
The customer-side main power supply and the used extension
line must meet these regulations.
Installations, repair, and maintenance work relating to the
electric installation may only be performed by specialists.
Important Notes
The electric motor has been designed for the S 1 operating
mode.
In case of an overload of the motor, it turns off automatically.
After a cooling period (duration varies), you can turn on the
motor again.
mDefective Electric
Connection Lines
Often, insulation damage occurs on electrical connection
lines.
Causes are:
1. Drag marks if connection lines are led through window or
door clearances.
-
nection line.
4. Insulation damages caused by pulling the connection
line out of the wall socket.
5. Fissures caused by the aging of the insulation.
Such defective electric connection lines must not be used and
are hazardous due to the insulation damages.
Regularly check the electrical connection lines for dam-
ages. Please make sure that the connection lines are dis-
connected from the mains supply during the check.
Electrical connection lines must comply with the relevant
VDE and DIN regulations. Only use connection lines la-
belled with H 07 RN. The labelling of the connection cable
motor Fig. 12
1. The supply voltage must be 110 V / 60 Hz.
2. Extension lines up to a length of 75 feet must have a
cross section of AWG 15. Extension lines with a length
of more than 75 feet must have a minimum cross sec-
tion of AWG 10.
3. The mains connection is protected with a delay-action
fuse of 16 A.
1. Motor manufacturer
3. Data from the machine type plate
4. Data from the switch type plate
If you return the motor, always return the complete drive unit
with the switch.