Universal rotary dimmer insert for LED lampsSBD200LED Art. no. MEG5 13 4-0000© Schneider-Electric 2014S1B97984-0005/14
¼
DANGER
Risk of serious damage to property and per-
sonal injury, e.g. from fire or electric shock,
due to incorrect electrical installation.
Safe electrical installation can only be ensured if
the person in question can prove basic knowl-
edge in the following areas:
•Connecting to installation networks
•Connecting several electrical devices
•Laying electric cables
These skills and experience are normally only
possessed by skilled professionals who are
trained in the field of electrical installation technol-
ogy. If these minimum requirements are not met
or are disregarded in any way, you will be solely li-
able for any damage to property or personal inju-
ry.
¼
DANGER
Risk of death from electric shock.
The outputs may carry an electrical current even
when the device is switched off. Always discon-
nect the fuse in the incoming circuit from the sup-
ply before working on connected loads.
Universal rotary dimmer insert for
LED lamps
Operating instructions
SBD200LED
Art. no. MEG5134-0000
For your safety
ende
With the Universal rotary dimmer insert for LED lamps
(hereafter referred to as dimmer) you can switch and
dim ohmic, inductive or capacitive loads:
The dimmer automatically recognises the connected
load. It is overload-proof, short-circuit-proof, protected
from overheating and it has a soft-start function.
Yo u c a n s e t t h e d i m m i n g r a n g e a n d a d j u s t t h e o p e r a t i n g
mode (from trailing edge phase to leading edge phase).
½
CAUTION
The dimmer may be damaged!
•Always operate the dimmer according to the
technical data provided.
•Connected dimmers may be damaged if you
connect a combination of loads (inductive and
capacitive) at the same time.
•The dimmer is designed for sinusoidal mains
voltages.
•If transformers are used, only connect dimma-
ble transformers to the dimmer.
•Dimming socket outlets is prohibited. The risk
of overload and connecting unsuitable devices
is too high.
•If a terminal is used for looping, the insert must
be protected with a 10 A circuit breaker.
|
Connect three dimmers at most to one cable with
16 A fuse protection.
|
If you do not install the dimmer in a single, stand-
ard flush mounting box, the maximum permissi-
ble load is reduced due to the decreased heat
dissipation:
* If several factors apply, add the load reductions
together.
Ge t t i n g t o k n o w t h e u n i v e r s a l d i m m e r
Dimmable LED lamps
Incandescent lamps
(ohmic load)
230 V halogen lamps
(ohmic load)
Low-voltage halogen lamps with
dimmable wound transformer
(inductive load)
Low-voltage halogen lamps with
electronic transformer
(capacitive load)
Installing the device
Load reduced
by
When installed
25 %
In cavity walls*
Several installed together in
combination*
30 % In 1-gang or 2-gang surface-
mounted housing
50 % In 3-gang surface-mounted housing
Wiring the insert
Installing the dimmer
Dimming range
The dimming range of the dimmer can, if necessary,
be adapted to the dimming range of lamps from different
manufacturers.
Setting the dimming range
|
Depending on the dimming range of the lamp,
malfunctions may occur for values near the maxi-
mum and minimum brightness. (Refer to the
chapter "What should I do if there is a problem?")
Setting the device
L
N
OR
XLL
Setting the minimum and maximum
brightness value
1 Set the potentiometer to MINA/MAXB.
2 Hold the micro button down for 5 seconds.
(The lamp lights up briefly.)
3 Tu r n t h e r o t a r y k n o b t o t h e d e s i r e d m i n i m u m /
maximum brightness.
4 Press the micro button briefly.
The selected brightness is saved as the minimum/
maximum brightness and the set mode is closed.
Operating mode
The default setting of the dimmer is the RC mode. The
dimmer recognises the connected load automatically,
however this can lead to malfunctions in some lamps
(see manufacturer's specifications). In this case you can
adjust the operating mode.
Switching the operating mode to RL LED mode
1 Set the potentiometer to RL(LED).
2 Hold the micro button down for 5 seconds.
(The lamp lights up briefly.)
The operating mode is switched to "leading edge phase
for LED lamps" (RL LED mode) and the minimum/
maximum brightness value is reset.
|
In the operating mode "leading edge phase for
LED lamps" (RL LED mode), LED lamps can only
be connected at up to 10 % of the maximum
permissible dimmer load.
1
2
4
3
5 sec
A
B
RL(LED)
MIN MAX
RESET
1
2
RL(LED)
MIN MAX
RESET
5 sec
A Press the rotary knob: the connected lamps are
switched-on or off.
B Tu r n t h e ro t a r y k no b e i th e r clockwise or anti-clock-
wise: the connected lamps are dimmed brighter or
darker.
Resetting to default mode
1 Set the potentiometer to RESET.
2 Hold the micro button down for 5 seconds.
(The lamp lights up briefly.)
The operating mode is switched to "trailing edge phase"
(RC mode) and the minimum/maximum brightness value
is reset.
Operating the device
A
B
1
2
RL(LED)
MIN MAX
RESET
5 sec
The dimmer dims down regularly during operation
and cannot be dimmed up again.
•Allow the dimmer to cool down and reduce the
connected load.
The load cannot be switched back on.
•Allow the dimmer to cool down and reduce the
connected load.
•Rectify any possible short circuits.
•Renew defective loads.
The load is dimmed to the minimum brightness.
•The circuit is overloaded. -> Reduce load.
•The circuit falls short of the minimum load. -> Increase
load.
•Dimming range is incorrect. -> Reduce maximum
brightness value.
The load flickers at minimum brightness.
The circuit falls short of the minimum possible brightness
value.
•Increase minimum brightness value (set dimming
range).
The load flickers continuously.
Incorrect operating mode set.
•Switch operating mode to "leading edge phase for
LED lamps" (RL LED mode).
•Alternatively, reset operating mode to default.
The load can only be dimmed slightly.
Set dimming range.
•Switch operating mode to "leading edge phase for
LED lamps" (RL LED mode).
Gothaer Straße 29, 40880 Ratingen
www.merten.com
www.merten-austria.at
Customer care centre:
What should I do if there is a problem?
Te c hni c al data
Nominal voltage: AC 230 V , 50/60 Hz
Switching capacity:
LED lamps
(RC mode): 4-200 VA
LED lamps
(RL LED mode): 4-40 VA
Incandescent lamps: 4-400 W
230 V halogen
lamps: 4-400 W
LV halogen lamps with
dimmable
wound transformer: 4-400 VA
LV halogen lamps with
electronic
transformer: 4-400 VA
Neutral conductor: Not required
Connecting terminals: Screw terminals for
max. 2.5 mm
2
Protection: 16 A circuit breaker
Properties: •Short-circuit-proof
•Overload-proof
•Soft start
•Resistant to overheating
•Automatic load detection
Schneider Electric GmbH c/o Merten
Phone: +49 2102 - 404 6000
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

schneider-electric-merten--meg5134-0000

Suche zurücksetzen

  • Guten Tag,
    ich habe eine Grossmann LED
    Karre 77-783-178 7x6,4 Watt montiert.
    Welcher Dimmer passt da am besten dazu?
    Ich habe den Merten MEG 5134 0000 als Aus-Wechsel in der Auswahl.
    Passt dieser?
    Was empfehlen Sie?
    Was hat dieser für einen Durchmesser an der Welle/Zapfen

    Freundliche Grüße
    Ewald Schneider
    Eingereicht am 23-2-2023 12:21

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Schneider Electric Merten MEG5134-0000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info