CONNECT radio receiver, flush-mounted, 1-gang switchArt. no. MTN507501© Merten2005V5075-561-0009/08
¼
DANGER
Risk of fatal injury due to electrical current
All work on the device should only be carried out
by trained and skilled electricians. Observe the
country-specific regulations.
½
CAUTION
If you operate devices that do not correspond to
the technical specifications (see technical data),
the connected devices and dimmers may get
damaged.
Connect only one phase (AC 230 V) towards
neutral conductor or functional extra-low volt-
age (FELV) to the make contact.
Do not connect the flush-mounted receiver to
different phases.
In the flush-mounted receiver, the make con-
tact is only separated from the phase by basic
insulation. You must therefore not connect any
safety extra-low voltage (SELV) (safety level
overridden).
The flush-mounted CONNECT radio receiver for the
switch will be referred to in the following as "the flush-
mounted receiver".
The flush-mounted receiver can be used to switch loads
on and off via radio (for information on allowed loads, see
the technical data). When it receives the radio signal, the
flush-mounted receiver switches the corresponding con-
tact.
|
The flush-mounted receiver cannot be used in a
wired two-way circuit.
CONNECT radio receiver, flush-
mounted, 1-gang switch
Operating instructions
Art. no. MTN507501
For your safety
Flush-mounted receiver introduction
en
¼
DANGER
Risk of fatal injury from electric current.
The device has no basic insulation and must
therefore be installed in a way that protects
against accidental contact.
¼
DANGER
Risk of fatal injury from electrical current.
Once a cover A is installed, the distance from
the fixing brackets or screws to the connections of
device B must be at least 4 mm.
If the distance is less than 4 mm, a deeper instal-
lation box must be used.
Also, the fixing brackets or screws of the cover
must not press against the housing.
½
CAUTION
The device can be damaged if not correctly
protected.
The circuit containing the connected loads must
be protected by a fuse with a rating not greater
than 16A.
Simply install the flush-mounted receiver "invisibly" near
the load to be connected, for example in a flush-mounted
socket with a blanking cover.
1 Connecting the flush-mounted receiver.
2 Installing the flush-mounted receiver.
Installing the flush-mounted receiver
B
> 4 mm
A
N
LN
L
10 A
|
Place the antenna as far as possible from metal
parts (connecting cables, retaining rings, etc.) to
avoid interruptions to the radio signal.
|
Metal surfaces in the immediate vicinity (e.g.
flush-mounted metal outlets, metal door frames)
can affect reception.
You can operate the flush-mounted receiver using the
following operating elements:
A taught CONNECT transmitter (e.g. CONNECT radio
push-button/CONNECT sensor surface).
Briefly press switch button B on the device
: this switches the channel.
Only insulated tools may be used for operation on the de-
vice, e.g. an insulated phase tester.
If the flush-mounted receiver is configured with EASY
CONNECT, not all functions/channels can be used. A
description of the EASY CONNECT radio system can be
found in the separate "CONNECT radio system" descrip-
tion, which is supplied with devices with system adminis-
tration (e.g. CONNECT radio push-button).
|
You can analyse and check faults throughout the
radio system with the help of the CONNECT radio
USB data interface (on a suitable PC) and the
CONNECT radio configuration tool.
The device does not react to the taught
transmitter:
Make sure that the maximum range is not exceeded
and that there are no metal surfaces such as metal
cabinets in the radio transmission path.
If necessary, check that the battery is placed correctly
in the radio push-button and that it is not flat.
Make sure that the device is not in programming
mode. (If the LED is flashing, this is the case.)
If necessary, repeat the teaching process.
Operating the flush-mounted receiver
A LED
B Switch button
What should I do if there is a problem?
A
B
NL**
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Schneider Electric MTN507501 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Schneider Electric MTN507501

Schneider Electric MTN507501 Bedienungsanleitung - Deutsch, Holländisch, Französisch, Italienisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info