29
Inspecting and Cleaning the O-ring, Gasket and contact surfaces
1. Carefully inspect the O-ring and Gasket for cuts(A), tears(B).
Replace O-ring and Gasket if damaged.
2. Carefully inspect O-ring contact surfaces and groove for
scratches or other damage. It is normal to see molding “seams”
near the hinge and latch area. Contact the SeaLife service center
in your country if the contact surfaces or groove are damaged.
3. Use a moist, clean cotton cloth to remove hair (C), sand (D),
and other debris from O-ring, Gasket, O-ring groove and
contact surfaces. Never stretch the O-ring or Gasket.
Installing the O-ring and Gasket
1. Install clean O-ring into groove. Be careful not to twist O-ring.
2. Install clean Gasket, making sure it is completely seated
against the waterproof door. The grooved side of the Gasket
should sit flat against the waterproof door.
3. Plug the cable adapter into the flash. Do NOT use force. Check
that the white cable adapter is correctly oriented with the plug.
Important
1. Do not lubricate the O-ring or Gasket.
2. Do not exceed operating depth of 200ft/60m.
3. Do not open waterproof door in wet environment. You and the