The Grand Seiko Standard defined
Item Unit Standard Cal. 9S27 Special
Standard
Mean daily rate in
six positions Second/day −3.0 +5.0 −3.0 +8.0 -2.0 +4.0
Mean variation of
daily rate Second/day Less than 1.8 Less than 3.2 Less than 1.6
Maximum daily
rate between two
consecutive daily
rates in the same
position
Second/day Less than 4.0 Less than 6.0 Less than 3.0
Variation of rate
between
positions
horizontal and
vertical
Second/day -6.0 +8.0 -8.0 +10.0 -5.0 +7.0
Maximum daily
rate between
mean daily rate
and any
individual rate
Second/day Less than 8.0 Less than 13.0 Less than 7.0
Variation of daily
rate per 1 °C
between 8 °C and
38 °C
Second/day/ -0.5 +0.5 -0.6 +0.6 -0.3 +0.3
Variation of daily
rate per 1 °C
between 23 °C
and 38 °C
Second/day/ -0.5 +0.5 -0.6 +0.6 -0.3 +0.3
Rate-resumption Second/day -5.0 +5.0 -6.0 +6.0 4.0
Number of positions in inspection 6 positions
Condition of temperature
in inspection 8, 23, 38
Length of tests 17 days
36 THE GRAND SEIKO STANDARD
Description of Grand Seiko Standard Terminology
Item Meaning
Position in inspection
Five orientations are specified by the International Standard ISO3159
so as to carry out various kinds of tests for time keeping. In addition
thereto, in the GS inspection, 12 o’clock Up position in the state where
a watch taken off the wrist is placed, is added, six orientations are
specified. (Dial Up, Dial Down, 12 o’clock Up, 3 o’clock Up, 6 o’clock
Up, and 9 o’clock Up)
Mean daily rate in six
positions
Mean value of a total of 12 daily rates measured in six different
positions, respectively, for two days. This is a target value indicating
basic loss/gain per day of a watch, however, it is required to
comprehensively judge the actual accuracy performance in
consideration of other items.
Mean variation of daily rate
Mean value of a total of six variations of daily rates between the first
day and second day when measured in six different positions for two
days each. It indicates the degree which daily accuracy stabilizes in
each position.
Maximum daily rate between
two consecutive daily rates in
the same position
Maximum value of a total of six variations of daily rates between the
first day and second day when measured in six different positions for
two days each. It indicates the degree which accuracy per day changes
at maximum according to positions.
Variation of rate between
positions horizontal and
vertical
Indicates loss/gain in two positions at which a watch is most frequently
used in daily life. It is a difference between mean daily rates for two
days when a watch is placed in the Dial Up position and mean daily
rates for two days when a watch is placed in the 6 o’clock Up position.
Maximum daily rate between
mean daily rate and any
individual rate
Maximum difference value between daily rates for 12 days in the test
initial stage and mean daily rates. It indicates the degree at which the
daily rate varies according to the manner for placing a watch.
Variation of daily rate per 1 °C
between 8 °C and 38 °C
Variation in daily rates per 1 between 38 and 8 in the same
position (Dial Up position). It indicates loss/gain in the temperature
environment (taken-off state from the wrist) where a watch is used.
Variation of daily rate per 1 °C
between 23 °C and 38 °C
Variation in daily rates per 1 between 38 and 23 in the same
position (Dial Up position). It indicates loss/gain in the temperature
environment (worn state of the wrist) where a watch is used.
Rate-resumption
Value obtained by subtracting mean daily rates of initial two days from
daily rate of the last inspection day. It indicates the degree at which
daily rate stabilizes after usage for a predetermined period.
The Grand Seiko Standard Inspection Certificate
This certificate accompanies your watch. It shows the precision values achieved by the
movement before the watch was cased and that the movement met the Grand Seiko
Standard. The precision tests were conducted in an artificially controlled environment in
our facility. The certificate shows the caliber number, the movement’s individual number
and the case’s individual number.
Normal usage accuracy of a mechanical watch varies depending on individual customer’s
use conditions such as winding state of the mainspring by movement amount of the
customer’s arm per day, temperature environment, and position (orientation of a watch).
Accordingly, the actual normal usage accuracy when the watch is used by a customer may
differ from the numerical value of each item specified in the Grand Seiko Standard.
bCAUTION
Your Grand Seiko Inspection Certificate is unique and cannot be replaced or reissued if lost
or after maintenance or adjustment.
37
THE GRAND SEIKO STANDARD
English
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Seiko 9S86 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Seiko 9S86

Seiko 9S86 Bedienungsanleitung - Deutsch - 25 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info