5-3-5.
Measuring in Radio Triggering Multiple (Cumulative) Flash Mode
Select Radio Triggering Multiple (Cumulative) Mode within
Custom Setting (See P55 for details.)
1. Touch the Measuring mode icon to open the
Measuring Mode Selection screen, then touch
the
icon to select Radio Triggering Multiple
(Cumulative) Mode and return the screen view to
Measuring screen. (See P25 for details.)
2. Set the ISO sensitivity value on the ISO icon.
3.
Set the shutter speed on the T (shutter speed) icon.
*
Be sure the settings are within the specications of the
ash equipment.
4.
To adjust ash intensity, touch the Power Control icon
and make adjustments as described in 5-3-3.
5.
Be sure the Channels and Zones are the same for
meter and the radio receivers in use.
6. Press the Measuring button
8
on the side of
meter to radio trigger the ashes and display the
measured exposure value (f-stop).
7.
Repeat this operation (pressing the Measuring button
8
on
the side of meter) only for the number of times necessary.
The accumulated measured value (f-stop) and the
number of cumulative ashes are displayed.
5-4. Out of Displayed Range or Measuring Range
(*This example explains what needs to be done in Cord (PC) Flash mode.)
5-4-1. When Displayed Range is Exceeded
For any given shutter speed and ISO setting, “Over” will be displayed when the measured light value requires an f-stop
setting that is greater than the maximum available f-stop (f/128). “Under will be displayed when low light requires a
setting lower than the minimum f-stop (f/0.5).
Example of Over Exposure Display Example of Under Exposure Display
1) When over exposure “Over” is displayed:
When the display range is exceeded and “Over” appears, make one of the following adjustments until a suitable
f-stop appears on the measuring display.
Change the T (shutter speed) to a faster setting.
Set the ISO sensitivity to lower setting.
If possible, lower the output power of light source, and take another measurement.
2) When under exposure “Under is displayed:
When the display range is exceeded and “Under” appears, make one of the following adjustments until a
suitable f-stop appears on the measuring display.
Change the T (shutter speed) to a lower setting.
Set the ISO sensitivity to higher setting.
If possible, raise the output power of light source, and take another measurement.
5-4-2. When Measuring Range is Exceeded
When the amount of light is outside the measuring range of the meter, the “Over” and “Under” displays will appear and blink.
When this happens, adjust the brightness level to obtain a measurement.
When brightness exceeds measuring range When brightness is under the measuring range
[ Measuring Screen ]
ControlTL
®
channel & zone
display
Standard channel &
zone display
Percentage
of ash
Setting
value
Measuring value (f-stop)
42

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sekonic L-478DR wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Sekonic L-478DR

Sekonic L-478DR Bedienungsanleitung - Holländisch - 68 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info