During the heating mode, water will condense from the air in the air conditioner and accumulate in the internal condensate tank. When the condensate tank is full, the display
C6 will show
(full condensate tank) and it will be necessary to remove the water from the condensate tank. Proceed according to the instructions in section Condensate
drain outlet later in this usersmanual. Once the condensate tank is empty, the air conditioner will start running again.
Note:
In the event that the air conditioner is located in avery cold room, to prevent potentially freezing, the air conditioner will start automatically heating the internal system.
It may stop running temporarily. The display C6 will show . Likewise, you may register an increased noise level. This is normal.
3. Fan mode
Repeatedly press button MODE D3 until the arrow on the display D1 stops at symbol .
Use button FAN D9 to set the fan speed. Repeatedly press button FAN D9 to switch the speed in the following order: High (high speed) – Medium (medium speed) – Low (low
speed). Each time the button is pressed, the arrow at the speed bar on the display D1 will switch.
Note:
In the fan mode, it is not possible to set the temperature, therefore no temperature information will be shown on the display D1.
4. Dehumidification mode
Repeatedly press button MODE D3 until the arrow on the display D1 stops at symbol . “dH” is shown on the display D1.
It is not possible to change the fan speed in the dehumidification mode.
5. Automatic mode
If you select an automatic mode, the portable air conditioner will automatically select an operating mode based on the temperature in the room.
Repeatedly press button MODE D3 until the arrow on the display D1 stops at symbol
.
Use button FAN D9 to set the fan speed. Repeatedly press button FAN D9 to switch the speed in the following order: High (high speed) – Medium (medium speed) – Low (low
speed) – Auto (automatic speed). Each time the button is pressed, the arrow at the speed bar on the display D1 will switch.
For models SAC MT9020C and SAC MT1220C (without the heating function) – the portable air conditioner will start in the fan mode, when the temperature in the room is less
than 23 °C, and in the cooling mode when the temperature in the room is higher than 23 °C.
For models SAC MT1224CH and SAC MT1225CH (with the heating function) – the portable air conditioner will start in the heating mode, when the temperature in the room
is less than 20 °C, in the fan mode if the temperature in the room is between 20 and 23 °C, and in the cooling mode when the temperature in the room is higher than 23 °C.
Functions of the portable air conditioner
1. Sleep function
The sleep function is used to reduce overnight power consumption, when aconstant temperature is not necessary.
Selecting an operating mode – heating or cooling – see previous part of the user’smanual.
Press button D5, symbol
will appear on the display D1. The portable air conditioner will run in the last selected mode.
If the cooling mode was selected, the temperature will increase by 2 °Cover aperiod of two hours. This new temperature will be maintained for aperiod of 6 hours and then the
portable air conditioner will turn itself off.
If the heating mode was selected, the temperature will decrease by 3 °Cover aperiod of three hours. This new temperature will be maintained for aperiod of 5 hours and then
the portable air conditioner will turn itself off.
The sleep function can be cancelled at any time by pressing button D5, D3 or D9.
The sleep function cannot be set in the fan and dehumidification modes.
2. Automatic start and shut-off function
Automatic start
The automatic start function makes it possible to set atime after which the portable air conditioner will start automatically.
Start the portable air conditioner by pressing button D1. Using button D3, select the operating mode in which you wish to turn on the portable air conditioner. Use buttons /
D7 and D8 to set the desired temperature and use button D9 to select afan speed as required. Turn off the portable air conditioner using button D1.
Press button D4 twice, the time and symbol will appear on the display D1. Use buttons / D7 andD8 to set atime after which the portable air conditioner will
automatically start. The automatic start time can be set in the range between 30 minutes and 24 hours (set in 30 minute intervals until 10 hours, and one hour intervals until 24 hours).
Press button D4 once to confirm the setting. The set time will appear on the display D1 and symbol will remain lit.
Once the set time elapses, the portable air conditioner will start automatically. If button D4 or D2 are pressed after the automatic start is set, then this setting will automatically
be cancelled.
Automatic shut-off
The automatic shut-off function makes it possible to set atime after which the portable air conditioner will shut off automatically.
While the portable air conditioner is turned on, press button D4 once. The time and symbol will be shown on the display D1.
Use buttons / D7 andD8 to set atime after which the portable air conditioner will automatically turn off. The automatic shut-off time can be set in the range between
30minutes and 24 hours (set in 30 minute intervals until 10 hours, and one hour intervals until 24 hours).
Press button D4 once to confirm the setting. The set time will appear on the display D1 and symbol will remain lit.
Once the set time elapses, the portable air conditioner will shut off automatically. If button D4 or D2 are pressed after the automatic shut-off is set, then this setting will
automatically be cancelled.
3. Flap angle setting function
Button D7 can be used to select either left or right air flow. Press button D7 once, an arrow and symbol will appear on the display D1. Pressing button D7 will cause the arrow
to disappear and the function to be cancelled.
Changing temperature units
While the air conditioner is in stand-by mode, press button D10 to toggle the temperature units from °Cto °F and vice versa.
MAINTENANCE AND CLEANING
Before cleaning the portable air conditioner, turn it off and wait afew minutes, and then pull the power cord out of the power socket.
Cleaning the air filters
When the portable air conditioner is used regularly, it is necessary to clean the filters located behind the protective grille of the top and bottom air inlets A7 and A9 at least once
every 14 days to prevent the fan from being clogged by dust.
Carefully remove the protective grille and take out the filters. To remove the dust, use avacuum cleaner. In the event of greater soiling, wash the filters by hand in asolution of
lukewarm water (max. 40 °C) and neutral detergent. Then thoroughly rinse under running water and allow to dry naturally. Do not dry it in aclothes dryer or in direct sunlight.
Once the filters are dry, you can install them back in their place.
Note:
Do not use the portable air conditioner without the air filters properly installed and do not use it with wet or damp air filters.
The water collection (condensation) tank must be drained immediately when the code “Ft” appears on the display C1 and also before this appliance is stored in order to prevent
the formation of moulds.
In households with pets, it is necessary to wipe the grille regularly to prevent it from becoming clogged by animal fur.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SAC MT1225CH wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info