- 13 - 09/2020 Copyright © 2020, F ast ČR, a.s.
A pressure test using OFN must be performed before refilling the system. In the case
of a leak, the system must be tested after being refilled but also before being put in to
operation. Av erification test must be performed before leaving the installation location.
9. T aking out of operation
Prior to performing this procedure it is essential that the technician fully acquain ts
him/herself with the device and all its particulars. Correct practice of safely collecting
all refrigerant is recommended. P rior to performing this activit y , oil and refrigerant
samples must be taken if an analysis is required prior to using the using the regenera ted
refrigerant for the first time. It is essential that prior to starting this activity that electricity
is available.
a) Acquainting one'sself with the device and its activity.
b) Electrical disconnection of the system.
c) Prior to star ting the procedure , ensure that:
– if required, mechanical device for handling the cylinder with refrigerant is available;
– all personal protective devices are available and used correctly;
– the collection process is constantly under the supervision of acompetent person;
– the collection device and c ylinders comply with respective norms.
d) Pump out the cooling system if possible .
e) If achieving vacuum is not possible, collection pipes are created to enable the
collection of refrigerant from various parts of the system.
f ) Ensure that the cylinder is placed on the scale before the collection of refrigerant is
started.
g) The collection device is turned on and runs according to the manufacturer'sinstructions.
h) Cylinders are not ov er filled. (No more than 80% of liquid cont ent capacity).
i) The maximum operating pr essure of the cylinder is not exceeded, even temporarily .
j) When the cylinders are properly filled up and the procedure is c omplete, ensure that
the cylinders and devices are immediately removed from the installa tion location and
that all the separation valves on the device are closed .
k) The collected refrigerant must not be filled into adifferent cooling sy stem until it is
cleaned and checked.
10. Marking with alabel
The appliance must be marked with a label indicating that it has been put out of
operation and is without refrigerant. The label must be dated and signed. It is ensured
that there are labels on the appliance indicating that it con tains flammable refrigerant.
11. Collection
When the refrigerant is collected from the system, either due to servicing or when
it is put out of operation, it is recommended to adhere t o proper practice and safely
collect all the refrigerant.
When the refrigerant is transferred in to the cylinders, it is necessary to ensure that
appropriate cylinders for collecting refrigerant are used.
It is necessary to ensure that there is asufficient number of cylinders available to contain
the complete contents of the syst em. All the cylinders that are to be used must be
intended for collecting refrigerant and be marked with alabel for this refrigerant (i.e.
special cylinders for collecting refrigerant). T he cylinders must be complete with asafety
valve and associated closing valves in good w orking condition. The empty collection
cylinders are pumped empty and if possible cooled prior to collecting refrigerant.
The collection device must be in good operating condition with a set of manuals relating
to the device, which are on hand and it must be suitable f or collecting flammable
refrigerants. Apart from this, a set of calibrated scales in good operating condition must
also be available. Hoses must be complete with couplers without seepage and in good
condition. Prior to using the collection device, check that it is in satisfactory operating
condition, has been properly maintained and all the associated electrical components
are sealed to prevent ignition in the ev ent of refrigerant being released. If in any doubt,
consult the manufacturer .
The collected refrigerant must be returned to the r efrigerant supplier in the correct
collection cylinder and with arespectively arranged waste transport letter. Refrigerant
are not to be mixed in the collection units and especially not in the cylinders.
In the event that compressors or compressor oils ar e to be collected, ensure that they
are pumped out to an acceptable level in or der to ensure that flammable refrigerant
does not remain in the lubricant. The pump discharge process must be performed before
the compressor is returned to the supplier . T o speed up this process, only electrically
heated compressor elements may be used . When the oil is drained from the system, it
must be disposed of safely .
TECHNICAL SPECIFICA TIONS
Power supply 220-240V~50Hz
Dehumidification capacity 30l/24h
Rated input power 715W
Rated current 3.2A
Energy factor EEV 2.2l/kWh
Starting current 11.0A
Fuse type and current value T3.15A
Condensate tank capacity 3l
Refrigerant type and weight R290/100g
GWP (global warming potential) 3
Equivalent CO2 0.0003 tons
Air flow volume 191/166m3 /h (high / normal fan speed)
Noise level 59/48.5dB(A) (high / normal fan speed)
Dimensions 386×260×500mm
Weight net / gr oss 17 / 18.2kg
Operating temperature 5 - 32°C
Recommended room area 58 - 73m2
The declared noise emission level of the appliance is 59 dB(A), which represents alev el
Aof acoustic power with respect to aref erence acoustic power of 1pW .
We reserve the right to change text and technical specifications .
INSTRUCTIONS AND INFORMA TION REGARDING THE
DISPOSAL OF USED P ACKAGING MA TERIALS
Dispose of used packaging material at asite designated f or waste in your municipality.
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT
This symbol on products or original documents means that used electric
or electronic products must not be added to ordinary municipal waste.
For proper disposal , renewal and recycling hand over these appliances
to determined collection points. Alternatively , in some European Union
states or other European countries you ma y return your appliances to
the local retailer when buying an equivalent new appliance.
Correct disposal of this product helps save valuable natural resour ces
and prevents potential negativ e effects on the environment and human
health, which could result from improper waste disposal . Ask your local authorities or
collection facility for more details.
In accordance with national regulations penalties may be imposed f or the incorrect
disposal of this type of waste.
For business entities in Eur opean Union states
If you want to dispose of electric or electronic appliances, ask your retailer or supplier
for the necessary information.
Disposal in other countries outside the European Union.
This symbol is valid in the European Union. If you wish to dispose of this product,
request the necessary information about the correct disposal method from the local
council or from your retailer .
This product meets all the basic requirements of EU directives rela ted to