cleaner until you hear aclick. This indicates the correct connection of
the attachment A15 to the floor nozzle A6.
In order to vacuum and wipe at the same time, set button A18 to the
position "OPEN". Some air will start flowing into the water tank, which
will gradually push water out through the wicks in the water tank A17
into the sleeve A19. Turn on the vacuum cleaner, and while vacuuming
you will also wipe the floor at the same time.
Note:
Regularly check the water/solution level in the water tank
A17, and fill it up as necessary.
When no longer using the wiping attachment A15, turn off the vacuum
cleaner and set button A18 to the position CLOSE. This will prevent air
from entering the water tank and the water will stop flowing out. Pull
the vacuum cleaner out in the upward direction.
CLEANING AND MAINTENANCE
Before cleaning, make sure that the vacuum cleaner is turned off and
the power adapter is disconnected from the power socket. In order to
extend the lifetime of the vacuum cleaner, we recommend you perform
cleaning and maintenance after every use.
Warning:
To prevent the risk of injury by electrical shock, do not
submerge the appliance, power cord or power plug in
water or any another liquid.
Dust container and filters
Press button A5 to release the dust container A11 from the body of the
hand vacuum cleaner. Move the dust container A11 over awaste bin.
Carefully pull filters A9 andA10 out of the dust container A11.
Tip out all the contents of the dust container A11 and rinse it out as
necessary under a current of cold running water. Allow it to dry and
check that the dust container A11 is completely dry before reassembly.
Pull the inner filter A9 out of the outer filter A10. Remove dust and soils
from the outer filter A10 rinse it out as necessary under acurrent of
cold running water. Allow it to dry and check that the outer filter A10 is
completely dry before reassembly.
Carefully remove any soils from the inner filter A9. If the inner filter A9 is
excessively soiled, rinse it under running water. Allow it to dry naturally.
Assemble the dust container A11 and filters A9 and A10 in reverse
sequence.
Warning:
Before assembling the vacuum cleaner, make sure
that all its parts are completely dry. Prior to starting it,
make sure that all the filters are properly installed in
their place. Otherwise, this could damage the vacuum
cleaner.
When filters are soiled, their effectiveness is reduced,
so do not neglect their cleaning.
It is recommended to replace the inner filter with a new one after
6 months of use. Spare filters are available at brick and mortar, and
online stores.
Floor nozzle
If the rotary brush A14 is soiled, turn the floor nozzle A6 so that the
rotary brush A14 is pointing upwards. On the left side of the nozzle A6
there is alatch that secures the brush cover in place. Release the latch,
tilt open the cover and take out the brush A14.
Remove all dirt and dust from the rotary brush A14 and the internal
space of the floor nozzle A6. After cleaning, return the rotary brush A14
back in its place. Tilt the cover back and secure in place.
For cleaning the surface of the floor nozzle A6, use adry or a lightly
dampened cloth. Then wipe everything so that it is thoroughly dry.
Outer surface of the vacuum cleaner
Clean the outer surface of the vacuum cleaner using adry or alightly
dampened cloth. Then wipe everything so that it is thoroughly dry.
Warning:
Do not clean any part of the vacuum cleaner using
steel wool, abrasive cleaning products, petrol, solvents
or any other similar products.
Cleaning the wiping attachment
Always empty out the tank A17 after every use of the attachment A15.
Wipe the attachment A15 with asoft sponge lightly dampened in warm
water. Wipe dry using aclean wiping cloth.
Remove the sleeve A19 and wash it by hand in cold water. Allow it to
dry naturally.
Warning:
Under no circumstances submerge or wash the
attachment A15 in water or any other liquid.
Storage
When not using the vacuum cleaner for an extended period of time,
clean it according to the instructions provided above.
Before storing it, check that the vacuum cleaner is perfectly clean and
dry.
Store the vacuum cleaner in adry, clean and well-ventilated location
not exposed to extreme temperatures and out of children'sreach.
TECHNICAL SPECIFICATIONS
Power adapter
Input ........................................................................... 100 – 240V~, 50/60Hz, 1.0A
Output ..............................................................................................47V , 0.5mA
Electrical shock protection class ...............................................................................II
Vacuum cleaner
Power input ...........................................................................................................160W
Electric rotary brush ................................................................................................ 5W
Li-Ion battery.........................................................40.7 V , Li-Ion / 2200 mAh
Time required for charging to full capacity ...............approximately 5 hours
Operating time when fully charged (high / low power) .....30 min / 85 min
Noise level ......................................................................................................... 75 dB(A)
Dust container capacity ..........................................................................................0.5l
The declared noise emission level of the appliance is 75 dB(A), which
represents alevel Aof acoustic power with respect to areference acoustic
power of 1pW.
Safety class for electrical shock protection:
Class II – Electrical shock protection is provided by double or
heavy-duty insulation.
The product is intended for household use only. The product
is not intended for outdoor use.
Thoroughly read the all the instructions before using the
product.
Product with protection class III: product is built for safety
extra-low voltage. Electrical shock protection is provided by
safety extra-low voltage.
We reserve the right to change text and technical specifications.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SVC 0741 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info