759449
7
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
- 7 - 11/2019
Copyright © 2019, Fast ČR, a.s.
EN Bagless vacuum cleaner
User'smanual
Prior to using this appliance, please read the user’smanual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of
appliances. Only use the appliance in the manner described in this user’smanual.
Keep this user’smanual in asafe place where it can be easily retrieved for future use.
We recommend saving the original cardboard box, packaging material, purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event
of transportation, we recommend that you pack the appliance in the original box
from the manufacturer.
DESCRIPTION OF THE APPLIANCE
A1
Dust container release button
A2 Handle
A3 Automatic power cord winding
button
A4 Suction power adjustment button
A5 On/Off button
A6 Rubber-coated travel wheel
A7 Removable dust container
A8 Flexible hose end connection hole
A9 Flexible hose end
A10 Flexible hose
A11 Telescopic metal tube
A12 Floor nozzle with an extensible
brush and DEEP cleaning and EASY
cleaning switch
A13
Flap for extending and retracting the brush
A14
Crevice nozzle with an extensible brush
A15 Dust container open clip
A16 HEPA filter H13
A17 Removable grille
A18 Inflow micro-filter
A19 Cyclone unit
A20 Groove for the horizontal parking
position
A21 Motor filter
A22 Long crevice nozzle
BEFORE FIRST USE
Before first use, take the appliance and its accessories out of the packaging material
and remove all promotional labels and stickers. Check that neither the appliance nor
any of its parts is damaged.
INTENDED USE OF THE ACCESSORIES
The universal floor nozzle with an extensible brush A12 is intended for all floor
types. Extend the brush when vacuuming smooth hard floors, and retract it when
vacuuming carpets. To extend and retract the brush, use flap A13 on the floor
nozzle A12. Floor nozzle A12 also has aswitch for extending out atravel roller. This
switch is located in the centre of the floor nozzle A12 and it has two positions - deep
cleaning and easy cleaning. The deep cleaning position (the travel roller is retracted)
is ideal for deep and thorough vacuuming of carpets. The easy cleaning position (the
travel roller is extended) makes movement over the vacuumed surface easier. We
recommend to slightly lift up the floor nozzle A12 when you wish to switch to the
easy cleaning position.
The crevice nozzle A14 makes for easier vacuuming of corners, hard to reach places,
and after extending the brush also furniture, upholstery, curtains, blinds, etc.
The long crevice nozzle A22 enables the vacuuming of dust and dirt from narrow,
hard-to-reach places in corners or behind furniture.
PREPARING FOR USE
Check that the dust container A7 with the micro-filter A18 and cyclone unit A19 are
properly installed in the vacuum cleaner.
Slide the end of the flexible hose A9 fully into the hole A8. The hose A9 is secured in
place when an audible click is made.
Note:
Prior to disassembly, it is necessary to press the latches on the hose end
A10 while simultaneously pulling it out of the hole A8.
Attach the telescopic tube A11 on to the handle of the flexible hose A10. Slide
the clip on the telescopic tube A11 in the direction of the arrow marked on the
extension locking clip on the telescopic tube A11. Set the length of the tube A11
by sliding its extensible part in or out. When the clip is released, it will lock in at
the set length.
Connect the floor nozzle A12 to the free end of the telescopic tube A11.
The crevice nozzle A14, or long crevice nozzle A22 can be connected directly to the
handle of the flexible hose A10 or the telescopic tube A11.
The flexible hose A10, metal telescopic nozzle A11, combination floor nozzle A12,
have apractical click-in system for simple and secure connection of the individual
accessory parts. Accessories equipped with this system easily and quickly fit into
each other; simply press the click-in system clip to release them.
USING THE VACUUM CLEANER
Pull on the power plug to wind out the required length of the power cord and
connect it to apower socket.
Attention:
The yellow mark on the power cord indicates the approaching
end of its length, and the red mark indicates the complete end of
its length. Do not attempt to pull the power cord past this mark.
To start the vacuum cleaner, press the On/Off button A5. Use button A4 to set the
suction power of the vacuum cleaner.
The rubber-coated wheels A6 protect floating floors against scratching and ensure
smooth motion of the vacuum cleaner on the floor.
When you have finished vacuuming, turn off the vacuum cleaner by pressing the
On/Off button A5 and disconnect the power cord from the power socket. To wind
the power cord back into the vacuum cleaner, hold down button A3 until its entire
length is wound up. Gently hold the power cord with one hand while winding it up.
Note:
If the power cord is not wound up completely, release button A3, and
pull the power cord out of the vacuum cleaner by approximately 50 cm
and then try to wind it up again.
PARKING POSITION OF THE VACUUM CLEANER
When not using the vacuum cleaner, you may put it in the parking position by sliding
the guide tab on the floor nozzle A12 into the groove A20.
Do not carry the vacuum cleaner while it is in the parking position. Otherwise, the
guide tab on the floor nozzle A12 could brake off.
CLEANING AND MAINTENANCE
Disconnect the power plug from the power socket before cleaning.
Warning:
To prevent the risk of injury by electrical shock, do not submerge
the appliance, power cord or power plug in water or any another
liquid.
Emptying and cleaning the dust container
We recommend regularly emptying and cleaning the dust container A7.
In order to be able to remove the dust container A7 from the vacuum cleaner, push
the dust container release button A1 and pull on the handle A2 to remove the dust
container A7 from the vacuum cleaner. Position it over adust bin and press the
dust container open clip A15. This will open the tilt-out bottom and dump out the
contents of the container A7.
Gently tap on the sides of the container A7 to release any accumulated dirt. For
hygiene reasons, we recommend emptying out the dust container A7 away from
living areas.
In order to clean the dust container A7, hold it with one hand and with the other
hand turn the handle A2 in the direction of the open padlock symbol that is marked
on the dust container A7. Take the inflow micro-filter A18 and the cyclone unit A19
out of the dust container A7. Wash the container A7 under lukewarm running water
and thoroughly wipe it dry. Assemble the container A7 and close its bottom. Then
reinsert it back into the vacuum cleaner and make sure that it is properly secured in
the vacuum cleaner.
Cleaning and replacing the HEPA filter, micro-filter and motor filter
To ensure the reliable operation of the vacuum cleaner, it is necessary to regularly
clean and replace the filters. When filters are soiled, their effectiveness is reduced,
which reduces the effectiveness of the vacuum cleaner.
HEPA filter
In order to clean and replace the HEPA filter A16, it is first necessary to remove the
grille A17 at the rear of the vacuum cleaner. Then it is possible to remove the HEPA
filter A16. In the case of light soiling, tap it out. In the event of heavy soiling, wash
it under aweak current of running lukewarm water so that the water washes the
dirt out of the folds. Allow the HEPA filter A16 to dry naturally, then reinsert it and
secure it in place with the grille A17. It is recommended to replace the HEPA filter
with anew one after 6 months of use.
Inflow micro-filter
In order to clean and replace the inflow micro-filter A18, it is necessary to first
remove the dust container A7 out of the vacuum cleaner. Hold the dust container
with one hand and with the other hand turn the handle A2 in the direction of the
open padlock symbol that is marked on the dust container A7. Take the inflow
micro-filter A18 out of the dust container A7. Tap out its contents or wash it under
aweak current of running lukewarm water and allow it to dry naturally. Then insert
it back in its place. In the event of heavy soiling or wear and tear, replace the used
micro-filter A18 with anew one.
Motor filter
Remove the dust container A7 from the vacuum cleaner. If the motor filter A21 is visibility soiled,
tap it out or wash it under lukewarm running water and allow it to dry naturally. Install the motor
filter A21 and dust container A7 back into the vacuum cleaner. In the event that the motor filter
A21 is showing signs of wear or it is heavily soiled, replace it with anew one.
Note:
For hygiene reasons, we recommend that you tap out the filters away
from living areas.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SVC 1086 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info