759493
8
Zoom out
Zoom in
Vorherige Seite
1/9
Nächste Seite
- 8 - 07/2019Copyright © 2019, Fast ČR, a.s.
EN Cordless vacuum cleaner
User’smanual
CORDLESS VACUUM CLEANER
Prior to using this appliance, please read the user’smanual thoroughly, even in cases
where you have previously familiarised yourself with the operation of similar types of
appliances. Only use the appliance in the manner described in this user’smanual. Keep
this user’smanual in asafe place where it can be easily retrieved for future use.
We recommend saving the original cardboard box, packaging material, and purchase
receipt and responsibility statement of the vendor or warranty card for at least the
duration of the legal liability for unsatisfactory performance or quality. In the event of
transportation, we recommend that you pack the appliance in the original box from
the manufacturer.
DESCRIPTION OF THE VACUUM CLEANER AND ITS ACCESORIES
A1 Vacuum cleaner handle
A2 On/off button of the vacuum
cleaner
A3 Suction level button of the
vacuum cleaner
A4 Connecting cable (located in the
joint between the handle and the
body of the vacuum cleaner)
A5 Vacuum cleaner body
A6 LED indicators of charging and
battery level
A7 Dust container release button
A8 Dust container
A9 Floor nozzle release button
A10 Floor nozzle with an electric rotary
brush
A11 Washable external filter
A12 Washable internal HEPA type filter
A13 Power adapter charging socket
A14 Power adapter
A15 Hook for hanging the vacuum
cleaner
A16 Wall mount holder set (mount
required)
DESCRIPTION OF THE MOP ATTACHMENT
I1 Mop attachment
I2 Tank for water / solution with
cleaning detergent
I3 Filling outlets
I4 Removable Velcro mop cover
I5 Surface to attach the mop cover (at
the bottom of the attachment, not
shown)
I6 Removable panel with nozzles (at
the bottom of the attachment, not
shown)
BEFORE FIRST USE
Before first use, take the appliance and its accessories out of the packaging material
and remove all promotional labels and stickers. Check that neither the appliance nor
any of its parts is damaged.
ASSEMBLY AND DISASSEMBLY
Due to the safety reasons during the transport, the vacuum cleaner is delivered
disassembled. When assembling, please follow these steps (see also the process in the
picture B).
1. Connect the handle A1 to the vacuum cleaner body A5 so that the connecting cable
A4 is inside the connection. Secure the connection with the supplied screw.
2. Connect the floor nozzle A10 to the bottom part of the vacuum cleaner body A5.
The correct connection of the floor nozzle A10 is indicated by a click sound of
button A9.
3. In the end, insert the dust container A8 into the vacuum cleaner body A5. At first,
insert the bottom part of the dust container A8 at the angle of 30° in the vacuum
cleaner body A5 and then carefully attach the upper part of the dust container A8.
The correct attachment of the dust container A8 is indicated by aclick sound.
To dissemble, proceed in reverse sequence.
PARKING POSITION OF THE VACUUM CLEANER
Put the vacuum cleaner into the parking position by placing the tip of your foot on
the top of the floor nozzle A10 and with asimply forward movement of the handle
A1 secure the vacuum cleaner in the vertical position. The latch located at the front
of the elbow of the floor nozzle A10 will slide into the groove on the top cover of the
floor nozzle A10.
To release the vacuum cleaner from the parking position, place the tip of your foot on
the top of the floor nozzle A10 and tilt the hand A1 backwards. The latch located at
the front of the elbow of the floor nozzle A10 will slide out of groove on the top cover
of the floor nozzle A10.
CHARGING THE VACUUM CLEANER
Connect the connector of the power adapter A14 to the socket A13 and insert the
plug of the power adapter into the power socket.
Note:
Before charging, it is important the vacuum cleaner has been turned off
and has been tilted in the upright position. Do not turn on the vacuum
cleaner if it is being charged and the power adapter A14 is plugged in
the power outlet.
Once the adapter A14 has been inserted into the power socket, the vacuum cleaner
will switch to charging mode and LED indicators A6 will signal the power level. Afull
charge requires approximately 6 - 8 hours. The actual charging time depends on the
power level of the battery.
Once the charging process is complete, all LED indicators A6 will be lit. Disconnect the
power adapter A14 from the power socket.
Note:
This vacuum cleaner contains abuilt-in Li-ion battery. To ensure
the longest possible lifetime of the battery, we recommend:
- Do not unnecessarily leave the battery fully charged or
completely flat for too long.
- Do not keep the battery permanently fully charged. Its lifetime
will be extended by keeping it at approximately half charge.
- Do not fully discharge the battery.
USING THE VACUUM CLEANER
You may use the vacuum cleaner for vacuuming various types of floor coverings such
as for example hard floor coverings, carpets, etc.
Hold the vacuum cleaner by the handle A1 and release it from the parking position.
After releasing it from the parking position, the handle may be moved in the vertical
direction.
Start the vacuum cleaner by pressing button A2. The vacuum cleaner will run at the
full suction power. If you need to decrease the suction power, press the button A3. The
suction power of the vacuum cleaner will be decreased. Pressing the button A3, you
will increase again the suction power.
When you have finished using the vacuum cleaner, press the button A2 to turn it off.
Clean it according to the instructions in chapter “Cleaning and maintenance” and allow
it to charge according to the instruction in chapter “Charging the vacuum cleaner”.
Note:
The LED indicators A6 signal the batter power level. The
individual LED indicators will turn off as the battery gradually
discharges. If it is discharged fully, all LED indicators A6 will flash
and the vacuum cleaner will stop running.
If the rotary brush gets blocked while using, e.g. vacuuming larger amount of hair
or animal fur, the system will activate the automatic safety protection that stops the
rotary brush to protect it against damage. All LED indicators A6 will flash for about
10 seconds. Turn off the vacuum cleaner by pressing the button A2 and remove
the jammed hair or animal fur from the rotary brush – more information in chapter
“Cleaning and maintenance. Before turning the vacuum cleaner on again, ensure the
rotary brush, dust container A8 and filters A11 and A12 are clean.
MOUNTING THE WALL HOLDER
Before mounting the wall holder on awall, it is important that you check that the
installation location has no wires, conduits, pipes, etc. in the wall.
Warning:
Only use the supplied set of screws and dowels for the
installation. Under no condition should dowels and screws be
used that have adifferent diameter, different specifications and
which are not approved by the manufacturer as suitable for the
installation of this type of product.
1. Place the wall holder on the wall at the appropriate height and mark the points by
apencil where the holder will be situated – see picture C.
2. Drill three holes according to the marking.
3. Insert the supplied dowel into each hole.
4. Now, place the holder on the wall and secure it by screws. Ensure they are correctly
screwed.
5. Release the handle A1 from the vacuum cleaner body A5 and from below, slide the
hanging hook A5 on the back part of the handle A1 – see picture D. The correct
position of the hook A15 is indicated by aclick sound. Attach the handle A1 back to
the vacuum cleaner body A5.
6. Lift the vacuum cleaner and place it to the holder so that the hook A15 is aligned
with the groove in the holder. Carefully slide the hook A15 into the holder groove –
see picture E. Ensure the vacuum cleaner is securely fixed in the holder.
USING THE MOP ATTACHMENT
Attach the mop cover I4 to the surface I5. Place the mop attachment I1 with the
attached mop cover I4 on the ground. Fill in the tank I2 by water or solution with the
cleaning detergent. Avoid spilling water / solution from the filling outlets I3 of the tank
I2. Place the vacuum cleaner above the mop attachment I1 so that the projections on
the attachment I1 were aligned with the holes at the bottom part of the floor nozzle
A10. Wheels should fit in the construction of the attachment I1 - see picture J. Slightly
push the vacuum cleaner down until you hear aclick sound. That signalizes the correct
securing of the attachment I1 to the floor nozzle A10. Turn on the vacuum cleaner,
and meanwhile you vacuum, the wheels will push on the switches in the attachment
I1, these will release water / solution through the panel I6 into the mop cover I4 which
will wipe the floor.
Note:
Regularly check the level of water / solution in the tank I2 and fill it
in if needed.
If you no longer use the mop attachment I1, pull up the vacuum cleaner. The switches
in the attachment I1 will be automatically released and water / solution stops flowing.
CLEANING AND MAINTENANCE
Before cleaning, always make sure that the vacuum cleaner is turned off and the power
adapter is disconnected from the power socket. We recommend running the cleaning
and maintenance after each use to prolong the lifetime of your vacuum cleaner.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SVC 8936 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info