575970
37
Zoom out
Zoom in
Vorherige Seite
1/37
Nächste Seite
Instrucciones de uso
Manual de instruções
Bedienungsanleitung
Notice d’emploi
|
|
|
|
|
Instruction manual
Istruzioni per l’uso
Gebruiksaanwijzing
100-P Series
C
M
Y
CM
MY
CY
CMY
K
Contents
1
Contents
Important safety instructions ............................................................................................................................................................. 2
The ew 100 G3 evolution wireless series .......................................................................................................................................... 3
The frequency bank system ........................................................................................................................................................... 3
Product overviews .................................................................................................................................................................................. 4
Overview of the EK 100 G3 diversity receiver ............................................................................................................................ 4
Overview of the SK 100 G3 bodypack transmitter ................................................................................................................... 5
Overview of the SKM 100 G3 radio microphone ........................................................................................................................ 6
Overview of the SKP 100 G3 plug-on transmitter ..................................................................................................................... 7
Overview of the displays of the EK 100 G3 ................................................................................................................................ 8
Overview of the displays of the SK 100/SKM 100/SKP 100 G3 ............................................................................................. 9
Putting the devices into operation ................................................................................................................................................... 10
EK 100 G3 diversity receiver ........................................................................................................................................................ 10
SK 100 G3 bodypack transmitter ............................................................................................................................................... 12
SKM 100 G3 radio microphone .................................................................................................................................................... 13
SKP 100 G3 plug-on transmitter ................................................................................................................................................. 15
Using the devices .................................................................................................................................................................................. 16
Switching the devices on/off ....................................................................................................................................................... 17
Synchronizing a transmitter with the diversity receiver ....................................................................................................... 19
Deactivating the lock mode temporarily ................................................................................................................................... 20
Muting the audio signal or deactivating the RF signal ........................................................................................................... 21
Selecting a standard display ........................................................................................................................................................ 22
Overview of the operating menus .................................................................................................................................................... 23
Synchronizing transmitters with diversity receivers ................................................................................................................... 26
Cleaning the devices ............................................................................................................................................................................. 28
If a problem occurs ... ........................................................................................................................................................................... 29
Specifications ......................................................................................................................................................................................... 31
Manufacturer Declarations ................................................................................................................................................................. 34
Detailed instruction manuals for the individual products can be found on the corresponding product
pages at www.sennheiser.com.
ew 100 P G3 Set _529660_0309_Sp9.book Seite 1 Mittwoch, 8. April 2009 6:57 18
Important safety instructions
2
Important safety instructions
Read this instruction manual.
Keep this instruction manual. Always include this instruction manual when passing the
products on to third parties.
Heed all warnings and follow all instructions in this instruction manual.
Use only a cloth for cleaning the products.
Do not place the products near any heat sources such as radiators, stoves, or other devices
(including amplifiers) that produce heat.
Only use attachments/accessories specified by Sennheiser.
When replacement parts are required, only use replacement parts specified by Sennheiser
or those having the same characteristics as the original part. Unauthorized substitutions
may result in fire, electric shock, or other hazards.
Refer all servicing to qualified service personnel.
Servicing is required if the products have been damaged in any way, liquid has been spilled,
objects have fallen inside, the products have been exposed to rain or moisture, do not
operate properly or have been dropped.
WARNING: To reduce the risk of fire or electric shock, do not use the products near water
and do not expose them to rain or moisture.
Intended use
Intended use of the ew 100 G3 products devices includes:
having read these instructions especially the chapter “Important safety instructions”,
using the products within the operating conditions and limitations described in this
instruction manual.
“Improper use” means using the products other than as described in these instructions, or
under operating conditions which differ from those described herein.
ew 100 P G3 Set _529660_0309_Sp9.book Seite 2 Mittwoch, 8. April 2009 6:57 18
The ew 100 G3 evolution wireless series
3
The ew 100 G3 evolution wireless series
With the ew 100 G3 evolution wireless series, Sennheiser offers high-quality state-of-the-art
RF transmission systems with a high level of operational reliability and ease of use. Transmit-
ters and receivers permit wireless transmission with studio-quality sound.
Adaptive diversity
The EK 100 G3 diversity receiver operates on the adaptive diversity principle where the shield
of the line cable is used as the second antenna to provide improved reception.
The frequency bank system
The devices are available in 6 UHF frequency ranges with 1,680 frequencies per frequency
range:
Each frequency range (A–E, G) offers 21 frequency banks with up to 12 channels each:
Each of the channels in the frequency banks “1” to “20” has been factory-preset to a fixed
frequency (frequency preset).
The factory-preset frequencies within one frequency bank are intermodulation-free.
These frequencies cannot be changed.
For an overview of the frequency presets, please refer to the supplied frequency information
sheet. Updated versions of the frequency information sheet can be downloaded from the
corresponding product page on our website at www.sennheiser.com.
The frequency bank “U” allows you to freely select and store frequencies. It might be that
these frequencies are not intermodulation-free.
Range A:
Range G: Range B:
Range C: Range D:
Range E:
516 – 558 626 – 668 734 776 823 865566 – 608 780 – 822
Frequency bank 1 ... 20
Frequency bank U
Channel 12 – frequency preset
Channel 1 – frequency preset
Channel 2 – frequency preset
Channel 12 – freely selectable frequency
Channel 1 – freely selectable frequency
Channel 2 – freely selectable frequency
ew 100 P G3 Set _529660_0309_Sp9.book Seite 3 Mittwoch, 8. April 2009 6:57 18
Product overviews
4
Product overviews
Overview of the EK 100 G3 diversity receiver
Operating elements
³ 3.5 mm jack socket, lockable (AF OUT)
(the shielding is used by antenna II)
· Antenna I
» Operation and battery status indicator,
red LED
(lit = ON/flashing = LOW BATTERY)
¿ RF signal indication, green LED
(lit = RF)
´ Charging contacts
² SET button
̆/̄ rocker button (UP/DOWN)
º Battery compartment
¾ Battery compartment cover
µ Battery compartment catches
¸ Infra-red interface
¹ ON/OFF button
(serves as the ESC (cancel) key in
the operating menu)
Ƹ Display panel, backlit in orange
·
»
¿
²
´
¹
¸
´
Ƹ
º
¾
µ
µ
³
ew 100 P G3 Set _529660_0309_Sp9.book Seite 4 Mittwoch, 8. April 2009 6:57 18
Product overviews
5
Overview of the SK 100 G3 bodypack transmitter
Operating elements
³ Microphone/instrument input (MIC/LINE),
3.5 mm jack socket, lockable
· MUTE switch
» Antenna
¿ Operation and battery status indicator,
red LED
(lit = ON/flashing = LOW BATTERY)
´ Audio overmodulation indicator,
yellow LED
(lit = AF PEAK)
² Charging contacts
SET button
º ̆/̄ rocker button (UP/DOWN)
¾ Battery compartment
µ Battery compartment cover
¸ Battery compartment catches
¹ Infra-red interface
Ƹ ON/OFF button,
serves as the ESC (cancel) key in
the operating menu
ƹ Display panel, backlit in orange
³
»
¿
´
²
Ƹ
¹
²
ƹ
¾
µ
º
¸
¸
·
ew 100 P G3 Set _529660_0309_Sp9.book Seite 5 Mittwoch, 8. April 2009 6:57 18
Product overviews
6
Overview of the SKM 100 G3 radio microphone
Operating elements
³ Microphone head (interchangeable)
· Name and pick-up pattern of the
microphone head (not visible here)
» Body of radio microphone
¿ Battery compartment (not visible from
outside)
´ Display panel, backlit in orange
² Infra-red interface
Antenna
º Color-coded protection ring;
available in different colors
¾ Operation and battery status indicator,
red LED
(lit = ON/flashing = LOW BATTERY)
µ Charging contacts
¸ Multi-function switch:
̄ (DOWN), ̆ (UP) and (SET)
¹ ON/OFF button,
serves as the ESC (cancel) key in the
operating menu
º
·
»
¿
´
²
¹
µ
µ
¾
µ
º
¸
ew 100 P G3 Set _529660_0309_Sp9.book Seite 6 Mittwoch, 8. April 2009 6:57 18
Product overviews
7
Overview of the SKP 100 G3 plug-on transmitter
Operating elements
³ Microphone input, XLR-3 socket
(female, unbalanced)
· Mechanical locking ring of
XLR-3 socket
» Infra-red interface
¿ Display panel, backlit in orange
´ UP button (
̆)
² DOWN button (
̄)
Operation and battery status indicator,
red LED
(lit = ON/flashing = LOW BATTERY)
º ON/OFF button
(serves as the ESC (cancel) key in the
operating menu)
¾ MUTE switch
µ SET button
¸ Battery compartment cover
·
»
³
¿
²
º
¾
µ
¸
´
ew 100 P G3 Set _529660_0309_Sp9.book Seite 7 Mittwoch, 8. April 2009 6:57 18
Product overviews
8
Overview of the displays of the EK 100 G3
After switch-on, the diversity receiver displays the standard display “Frequency/Name”.
For further illustrations and examples of the different standard displays, refer to page 22.
The display backlighting is automatically reduced after approx. 20 seconds.
Display Meaning
RF level “RF
(Radio Frequency)
Diversity display:
Antenna input I is active
Antenna input II is active
RF signal level:
Field strength of the received signal
Squelch threshold level
Audio level “AF
(Audio Frequency)
Modulation of the transmitter
Peak hold function
When the display shows full deflection, the audio
input level is excessively high.
Frequency Current receiving frequency
Name Freely selectable name of the receiver
Lock mode icon Lock mode is activated
Battery status Charge status:
Muting function
MUTE
or
Mute” is only displayed on the “Frequency/Name” standard
display (see page 22) when no RF signal is being received.
The diversity receiver then does not output an audio signal.
line output level
AF OUT
The line output level AF OUT is only displayed on the
Frequency bank/Channel/Name” standard display
(see page 22).
Pilot tone “P Activated pilot tone evaluation
MHz
533.875
ew100 G3
P
AFRF
MUTE
RF
AF
approx. 100%
approx. 70%
approx. 30%
Charge status is critical; in addition,
the red LOW BATT LED » is flashing.
EW100_P_Set_US_PRT.fm Seite 8 Donnerstag, 9. April 2009 12:14 12
Product overviews
9
Overview of the displays of the SK 100/SKM 100/SKP 100 G3
After switch-on, the transmitter displays the standard display “Frequency/Name”.
For further illustrations and examples of the different standard displays, refer to page 22.
The display backlighting is automatically reduced after approx. 20 seconds.
Display Meaning
Audio level “AF Modulation of the SK/SKM/SKP 100 G3
with peak hold function.
Frequency Current transmission frequency
Name Freely selectable name of the transmitter
Transmission icon RF signal is being transmitted
Lock mode icon Lock mode is activated
Pilot tone “P Pilot tone transmission is activated
MUTE Audio signal is muted
Battery status Charge status:
MHz
533.875
ew100 G3
MUTE
P
AF
approx. 100%
approx. 70%
approx. 30%
Charge status is critical, the red
LOW BATTERY LED /¿/¾ is flashing:
¿
P
¾
ew 100 P G3 Set _529660_0309_Sp9.book Seite 9 Mittwoch, 8. April 2009 6:57 18
Putting the devices into operation
10
Putting the devices into operation
EK 100 G3 diversity receiver
Inserting the batteries/accupack
For powering the diversity receiver, you can either use two 1.5 V AA size batteries or the
rechargeable Sennheiser BA 2015 accupack.
̈ Open the battery compartment by pushing the two catches µ in the direction of the
arrows and open the cover ¾.
̈ Insert the two batteries or the accupack as shown above. Please observe correct polarity
when inserting the batteries/accupack.
̈ Close the battery compartment by pressing on the center of the cover ¾.
The battery compartment cover ¾ locks into place with an audible click.
Charging the accupack
To charge the BA 2015 accupack:
̈ Insert the diversity receiver into the L 2015 charger (optional accessory).
The L 2015 simultaneously charges up to two devices, e.g. two diversity receivers or
one diversity receiver and one SK 100 G3 bodypack transmitter.
The L 2015 charger can only charge the BA 2015 accupack. Standard batteries
(primary cells) or individual rechargeable battery cells cannot be charged.
¾
¾
´
µ
ew 100 P G3 Set _529660_0309_Sp9.book Seite 10 Mittwoch, 8. April 2009 6:57 18
Putting the devices into operation
11
Mounting the diversity receiver to a camera
Use the supplied CA 2 camera adapter to mount the receiver to a camera’s flash mount.
̈ Determine where on the perforated plate ƹ the flash mount adapter ƺ will need to be
fastened so that the receiver can best be attached to the camera.
̈ At this position, place a square nut ƻ under the perforated plate ƹ.
̈ Fasten the flash mount adapter ƺ to the perforated plate ƹ using the square nut ƻ.
̈ Lift one side of the belt clip Ƽ as shown.
̈ Press down the belt clip Ƽ at one fixing point and pull it out of the receiver housing.
̈ Repeat for the other side.
̈ Place the perforated plate ƹ onto the rear of the receiver.
̈ Reinsert the belt clip Ƽ.
̈ Use one of the supplied line cables to connect the line input of the camera to the
socket ³.
ƹ
ƺ
ƻ
The shield of the line cable serves as the antenna for the second diversity section.
Ƽ
³
ew 100 P G3 Set _529660_0309_Sp9.book Seite 11 Mittwoch, 8. April 2009 6:57 18
Putting the devices into operation
12
SK 100 G3 bodypack transmitter
Inserting the batteries/accupack/Charging the accupack
The procedure is the same as for the EK 100 G3 diversity receiver:
To insert the batteries/accupack:
̈ Read the chapter “Inserting the batteries/accupack” on page 10.
To charge the accupack:
̈ Read the chapter “Charging the accupack” on page 10.
Connecting the microphone cable/line cable
The audio input is designed for the connection of condenser microphones. DC powering of the
condenser microphones is via the audio input MIC/LINE ³ (3.5 mm jack socket).
̈ Use one of the recommended Sennheiser microphones or the optional CL 2 line cable.
̈ Connect the 3.5 mm jack plug ƺ from the Sennheiser cable to the 3.5 mm jack socket
MIC/LINE ³.
̈ Lock the 3.5 mm jack plug by screwing down the coupling ring ƻ of the cable.
̈ Via the operating menu, adjust the sensitivity of the microphone/line input.
Attaching and positioning the corresponding microphones
ME 2/ME 4
̈ Use the microphone clip Ƽ to attach the microphone to clothing (e.g. tie, lapel).
The ME 2 clip-on microphone (shown on the right in the diagram) has an omni-directional
pick-up pattern. It is therefore not necessary to position it precisely.
̈ Attach the ME 2 microphone as close as possible to the sound source.
The ME 4 clip-on microphone (shown on the left in the diagram) has a cardioid pick-up
pattern.
̈ Position the ME 4 microphone so that its sound inlet is directed towards the sound source
(e.g. mouth).
³
ƻ
ƺ
Ƽ
ew 100 P G3 Set _529660_0309_Sp9.book Seite 12 Mittwoch, 8. April 2009 6:57 18
Putting the devices into operation
13
Attaching the bodypack transmitter to clothing
You can use the belt clip ƽ to attach the bodypack transmitter to clothing (e.g. belt, waist-
band).
The belt clip is detachable so that you can also attach the transmitter with the antenna
pointing downwards. To do so, withdraw the belt clip ƽ from its fixing points and attach it
the other way round. The belt clip ƽ is secured so that it cannot slide out of its fixing points
accidentally.
To detach the belt clip:
̈ Lift one side of the belt clip as shown in the diagram on the right-hand side.
̈ Press down the belt clip at one fixing point and pull it out of the transmitter housing.
̈ Repeat for the other side.
SKM 100 G3 radio microphone
̈ Only hold the radio microphone by its body.
Inserting the batteries/accupack
For powering the radio microphone, you can either use two 1.5 V AA size batteries or the
rechargeable Sennheiser BA 2015 accupack.
̈ Unscrew the lower part of the radio microphone from the radio microphone’s body » by
turning it counterclockwise.
̈ Slide back the lower part of the radio microphone as far as it will go.
̈ Open the battery compartment cover Ƹ (see page 14).
̈ Insert the batteries or the BA 2015 accupack as shown on the battery compartment
cover. Observe correct polarity when inserting the batteries/accupack (see page 14).
ƽ
If you touch the antenna of the radio microphone during operation, the trans-
mitter’s range will be considerably reduced!
»
When unscrewing the radio microphone during operation, the muting function is
automatically activated. “MUTE” appears on the display panel.
When screwing the lower part of the radio microphone back to the radio micro-
phone’s body, the muting is canceled.
ew 100 P G3 Set _529660_0309_Sp9.book Seite 13 Mittwoch, 8. April 2009 6:57 18
Putting the devices into operation
14
̈ Close the battery compartment cover Ƹ.
̈ Push the battery compartment into the radio microphone’s body.
̈ Screw the lower part of the radio microphone back to the radio microphone’s body.
Charging the accupack
To charge the radio microphone with the BA 2015 accupack (optional accessory) installed:
̈ Use the LA 2 charging adapter to insert the radio microphone into the L 2015 charger
(charger and charging adapter are available as optional accessories).
Changing the microphone head
The microphone head ³ is easy to change.
̈ Unscrew the microphone head ³.
̈ Screw the desired microphone head to the radio microphone.
The radio microphone is operational again.
Do not touch the contacts of the radio microphone nor the contacts of the micro-
phone head ³. The contacts can become dirty or damaged if touched.
When unscrewing the microphone head ³ during operation, the muting function is
automatically activated. “MUTE” appears on the display panel.
When screwing the microphone head ³ back to the radio microphone, the muting
is canceled.
Ƹ
Ƹ
³
ew 100 P G3 Set _529660_0309_Sp9.book Seite 14 Mittwoch, 8. April 2009 6:57 18
Putting the devices into operation
15
Changing the color-coded protection ring
The color-coded protection ring º prevents the multi-function switch ¸ from accidental
operation. Protection rings in different colors are available as accessories. The protection
rings allow you to clearly identify each radio microphone.
̈ Remove the color-coded protection ring as shown in the left-hand diagram.
̈ Put on a new protection ring as shown in the right-hand diagram.
SKP 100 G3 plug-on transmitter
Inserting the batteries/accupack
For powering the plug-on transmitter, you can either use two 1.5 V AA size batteries or the
rechargeable Sennheiser BA 2015 accupack.
̈ Slide the battery compartment cover ¸ in the direction of the embossed arrow and open
the cover.
̈ Insert the two batteries or the accupack as shown below. Please observe correct polarity
when inserting the batteries/accupack.
̈ Close the battery compartment.
The battery compartment cover ¸ locks into place with an audible click.
Charging the accupack
̈ Remove the BA 2015 accupack (optional accessory).
̈ Insert the BA 2015 accupack into the L 2015 charger (accupack and charger are optional
accessories):
º º
¸
¸
The L 2015 charger can only charge the BA 2015 accupack. Standard batteries
(primary cells) or individual rechargeable battery cells cannot be charged.
ew 100 P G3 Set _529660_0309_Sp9.book Seite 15 Mittwoch, 8. April 2009 6:57 18
Using the devices
16
Plugging the plug-on transmitter onto a microphone
̈ Plug the microphone’s XLR-3M socket onto the transmitter’s XLR-3F socket ³.
̈ Tighten the locking ring · in the direction of the arrow.
Using the devices
To establish a transmission link, proceed as follows:
1. Switch the diversity receiver on.
2. Switch a transmitter on.
The transmission link is established and the diversity receiver’s RF level display “RF
reacts.
If you cannot establish a transmission link between transmitter and diversity receiver:
̈ Make sure that transmitter and diversity receiver are set to the same frequency bank and
to the same channel.
̈ If necessary, read the chapter “If a problem occurs ...” on page 29.
The transmitter uses the microphone body as an antenna – therefore microphones
with a metal casing should be used for best signal transmission.
It is vital to observe the following notes:
̈ Make sure that the desired frequencies are listed in the enclosed frequency
information sheet.
̈ Make sure that the desired frequencies are approved and legal in your country
and, if necessary, apply for an operating license.
·
³
ew 100 P G3 Set _529660_0309_Sp9.book Seite 16 Mittwoch, 8. April 2009 6:57 18
Using the devices
17
Switching the devices on/off
EK 100 G3 diversity receiver
To switch the diversity receiver on:
̈ Push the two battery compartment catches µ and open the battery compartment
cover ¾.
̈ Press the ON/OFF button ¹.
The red ON LED » lights up and the standard display “Frequency/Name” appears on the
display panel.
To switch the diversity receiver off:
̈ Press the ON/OFF button ¹ until “OFF” appears on the display panel.
The red ON LED » goes off and the diversity receiver switches off.
When in the operating menu, pressing the ON/OFF button ¹ will cancel your entry
(ESC function) and return you to the current standard display.
¹
»
¾
µ
µ
ew 100 P G3 Set _529660_0309_Sp9.book Seite 17 Mittwoch, 8. April 2009 6:57 18
Using the devices
18
SK 100 G3 bodypack transmitter, SKM 100 G3 radio microphone and
SKP 100 G3 plug-on transmitter
To switch your transmitter on (online operation):
SK 100 G3 SKM 100 G3 SKP 100 G3
̈ Push the two catches ¸
and open the battery
compartment cover µ.
̈ Briefly press the ON/OFF
button Ƹ. The bodypack
transmitter transmits an
RF signal.
The red ON LED ¿ lights
up and the standard
display “Frequency/
Name” appears on the
display panel. The trans-
mission icon is
displayed.
̈ Briefly press the ON/OFF
button ¹.
The radio microphone
transmits an RF signal.
The red ON LED ¾ lights
up and the standard
display “Frequency/
Name” appears on the
display panel. The trans-
mission icon is
displayed.
̈ Briefly press the ON/OFF
button º.
The plug-on transmitter
transmits an RF signal.
The red ON LED lights
up and the standard
display “Frequency/
Name” appears on the
display panel. The trans-
mission icon is
displayed.
To switch your transmitter off:
̈ If necessary, deactivate the lock mode (see page 20).
̈ Press the ON/OFF
button Ƹ until “OFF
appears on the display
panel.
The display panel turns
off. The red ON LED ¿
goes off.
̈ Press the ON/OFF
button ¹ until “OFF
appears on the display
panel.
The display panel turns
off. The red ON LED ¾
goes off.
̈ Press the ON/OFF
button º until “OFF
appears on the display
panel.
The display panel turns
off. The red ON LED
goes off.
P
º
Ƹ
¿
¸
¸
¾
¸
µ
¹
µ
You can switch your transmitter on and deactivate the RF signal on switch-on.
For more information, refer to page 19.
When in the operating menu, pressing the ON/OFF button will cancel your entry
(ESC function) and return you to the current standard display.
ew 100 P G3 Set _529660_0309_Sp9.book Seite 18 Mittwoch, 8. April 2009 6:57 18
Using the devices
19
Synchronizing a transmitter with the diversity receiver
You can synchronize a suitable transmitter of the ew 100 G3 series with the diversity
receiver. During synchronization, the following parameters are transferred to the trans-
mitter:
To switch your transmitter on and to deactivate the RF signal on switch-on (offline operation):
SK 100 G3 SKM 100 G3 SKP 100 G3
̈ Keep the ON/OFF
button Ƹ pressed until
RF Mute On?” appears
on the display panel.
̈ Press the SET button .
̈ Keep the ON/OFF
button ¹ pressed until
RF Mute On?” appears
on the display panel.
̈ Press the multi-function
switch ¸.
̈ Keep the ON/OFF
button º pressed until
RF Mute On?” appears
on the display panel.
̈ Press the SET button µ.
The transmission frequency is displayed but the transmitter does not transmit an
RF signal.
The transmission icon is not displayed.
To activate the RF signal:
̈ Briefly press the ON/OFF
button Ƹ.
RF Mute Off” appears
on the display panel.
̈ Press the SET button .
The transmission icon
is displayed again.
̈ Briefly press the ON/OFF
button ¹.
RF Mute Off” appears
on the display panel.
̈ Press the multi-function
switch ¸.
The transmission icon
is displayed again.
̈ Briefly press the ON/OFF
button º.
RF Mute Off” appears
on the display panel.
̈ Press the SET button µ.
The transmission icon
is displayed again.
MHz
533.875
ew100 G3
MUTE
P
AF
MHz
533.875
ew100 G3
MUTE
P
AF
MHz
533.875
ew100 G3
MUTE
P
AF
Use this function to save battery power or to prepare a transmitter for use during
live operation without causing interference to existing transmission links.
Setting Transferred parameters
Frequency Preset Currently set frequency
Name Freely selectable name currently set on the receiver
Pilot Tone Current pilot tone setting of the receiver (“Inactive”/“Active”)
ew 100 P G3 Set _529660_0309_Sp9.book Seite 19 Mittwoch, 8. April 2009 6:57 18
Using the devices
20
To transfer the parameters:
̈ Switch the transmitter and the diversity receiver on.
̈ On the receiver, call up the “Sync” menu item.
Sync” appears on the display panel of the diversity receiver.
̈ Place the infra-red interface of the transmitter (see page 5 to page 7) in front of the
infra-red interface of the diversity receiver ¸.
The parameters are transferred to the transmitter. When the transfer is completed, “
appears on the display panel of the diversity receiver. The receiver then switches back to the
current standard display.
To cancel the transfer:
Press the ON/OFF button ¹ on the diversity receiver.
” appears on the display panel of the receiver. “ also appears if no suitable trans-
mitter was found (wrong frequency range/wrong generation).
Deactivating the lock mode temporarily
You can activate or deactivate the automatic lock mode via the “Auto Lock” menu item (see
page 23). If the lock mode is activated, you have to temporarily deactivate it In order to be
able to operate the devices:
¸
EK 100 G3/SK 100 G3 SKM 100 G3 SKP 100 G3
̈ Press the SET
button ² (EK) or
(SK).
̈ Press the multi-
function switch ¸.
̈ Press the SET
button µ.
Locked” appears on the display panel.
̈ Press the rocker
button (EK) or º
(SK).
̈ Move the multi-
function switch ¸
upwards/downwards.
̈ Press the
UP button ´/
DOWN button ².
Unlock?” appears on the display panel.
̈ Press the SET
button ² (EK) or
(SK).
̈ Press the multi-
function switch ¸.
̈ Press the SET
button µ.
The lock mode is temporarily deactivated.
P
¸
²
º
²
µ
´
ew 100 P G3 Set _529660_0309_Sp9.book Seite 20 Mittwoch, 8. April 2009 6:57 18
Using the devices
21
How you are using the devices determines how long the lock mode remains deactivated:
The lock mode icon flashes prior to the lock mode being activated again.
Muting the audio signal or deactivating the RF signal
SK 100 G3/SKP 100 G3
The MUTE switch · (SK)/ ¾ (SKP) allows you to mute the audio signal or to deactivate the
RF signal. Via the “Mute Modemenu item, you can set the desired function of the MUTE
switch · (SK)/ ¾ (SKP):
̈ From the “Mute Mode” menu item, select the desired setting (see page 25).
̈ Exit the operating menu.
̈ Slide the MUTE switch · (SK)/ ¾ (SKP) to the left, to the position MUTE.
The transmitter reacts as indicated in the table.
You can deactivate the RF signal of the transmitters (SKM 100 G3, SK 100 G3,
SKP 100 G3) on switch-on. For more information, refer to the chapter “Switching the
devices on/off” on page 17.
Using the ON/OFF button, you can also activate/deactivate the transmitters’ RF
signal during operation. To do so, briefly press the ON/OFF button and proceed as
described on page 19.
Setting Slide the MUTE switch · / ¾ ... Function
AF On/Off ... to the left (position MUTE) Mutes the audio signal
... to the right Unmutes the audio signal
RF On/Off ... to the left (position MUTE) Deactivates the RF signal
(offline operation)
... to the right Activates the RF signal
(online operation)
Disabled No function
When you are in the operating menu
The lock mode remains deactivated until you exit the operating menu.
When one of the standard displays is shown
The lock mode is automatically activated after 10 seconds.
·
MHz
533.875
ew100 G3
MUTE
P
AF
¾
ew 100 P G3 Set _529660_0309_Sp9.book Seite 21 Mittwoch, 8. April 2009 6:57 18
Using the devices
22
The current state of the muting function or the RF signal is displayed on the display panel of
the transmitter:
Selecting a standard display
EK 100 G3
Audio signal is muted
Transmitter’s display panel: MUTE is displayed
Audio signal is activated (muting is canceled)
Transmitter’s display panel: MUTE is not displayed
RF signal is deactivated
Transmitter’s display panel: Transmission icon is not displayed,
MUTE is displayed
RF signal is activated
Transmitter’s display panel: Transmission icon is displayed,
MUTE is not displayed
̈ Briefly press the ON/OFF button to select a standard display.
Contents of the display Selectable standard display
Frequency/Name
with “MUTE” display
Frequency bank/Channel/Name
with display of the line output level “AF OUT
ON/OFF
MHz
533.875
ew100 G3
P
MUTE
AFRF
B.Ch: 20.12
ew100 G3
P 0
AFRF
ew 100 P G3 Set _529660_0309_Sp9.book Seite 22 Mittwoch, 8. April 2009 6:57 18
Overview of the operating menus
23
SK 100/SKM 100/SKP 100 G3
To select a standard display:
Overview of the operating menus
EK 100 G3
SK 100 G3 SKM 100 G3 SKP 100 G3
̈ Press the rocker
button.
̈ Move the multi-
function switch.
̈ Press the UP
button/DOWN
button.
Contents of the display Selectable standard display
Frequency/Name
Channel/Frequency
Name/Channel
For more detailed information on the operating menus, refer to the individual
instruction manuals of the devices. These instruction manuals can be down-
loaded from the corresponding product pages at www.sennheiser.com.
ew100 G3
MHz
533.875
MUTE
P
AF
MHz
533.875
B.Ch: 20.12
MUTE
P
AF
B.Ch: 20.12
MUTE
P
AF
ew100 G3
Main menu
“Menu”
Sync
Squelch
Easy Setup
Frequency Preset
Name
AF Out
Auto Lock
Advanced
Exit
Tune
Pilot Tone
LCD Contrast
Reset
Software Revision
Exit
Extended menu
“Advanced Menu”
Reset List
Current List
Scan New List
Exit
“Easy Setup”
ew 100 P G3 Set _529660_0309_Sp9.book Seite 23 Mittwoch, 8. April 2009 6:57 18
Overview of the operating menus
24
When one of the standard displays is shown on the display panel, you can get into the main
menu by pressing the SET button ². The extended menu “Advanced Menu” and the “Easy
Setup” menu can be accessed via the corresponding menu items.
Display Function of the menu item
Main menu “Menu”
Sync Synchronizes a transmitter with the diversity receiver
Squelch Adjusts the squelch threshold
Adjustment range: “Low”, “Middle”,High”, can be switched off
Special function (for servicing purposes only): With the squelch threshold set to Low”,
you switch the squelch off by keeping the DOWN rocker button pressed for 3 seconds.
If you then press the UP button , you switch the squelch on again.
Easy Setup Scans for unused frequency presets, releases and selects frequency presets
Frequency Preset Changes the frequency bank and the channel
Name Enters a freely selectable name
AF Out Adjusts the audio output level
Adjustment range: –30 dB to +12 dB, adjustable in steps of 6 dB
Auto Lock Activates/deactivates the automatic lock mode
Advanced Calls up the extended menu “Advanced Menu
Exit Exits the operating menu and returns to the current standard display
“Easy Setup”
Reset List Releases all locked frequency presets
Current List Selects an unused frequency preset
Scan New List Automatically scans for unused receiving frequencies (frequency preset scan)
Exit Exits the menu “Easy Setup” menu and returns to the main menu
Extended menu “Advanced Menu”
Tune Sets the receiving frequencies for the frequency bank “U
Sets a channel and a receiving frequency for the frequency bank “U”:
̈ Select this menu item and call it up by pressing the SET button ² until the channel
selection appears.
Pilot Tone Activates/deactivates the pilot tone evaluation
LCD Contrast Adjusts the contrast of the display panel
Reset Resets the diversity receiver
Software Revision Displays the current software revision
Exit Exits the extended menu “Advanced Menu” and returns to the main menu
ew 100 P G3 Set _529660_0309_Sp9.book Seite 24 Mittwoch, 8. April 2009 6:57 18
Overview of the operating menus
25
SK 100/SKM 100/SKP 100 G3
Main menu
“Menu”
Sensitivity
Frequency Preset
Name
Auto Lock
Advanced
Exit
Tune
Pilot Tone
LCD Contrast
Reset
Software Revision
Exit
Extended menu
“Advanced Menu”
Main menu
“Menu”
Sensitivity
Frequency Preset
Name
Auto Lock
Advanced
Exit
Tune
Mute Mode
Cable Emulation
Pilot Tone
LCD Contrast
Reset
Software Revision
Exit
Extended menu
“Advanced Menu”
Main menu
“Menu”
Sensitivity
Frequency Preset
Name
Auto Lock
Advanced
Exit
Tune
Mute Mode
Pilot Tone
LCD Contrast
Reset
Software Revision
Exit
Extended menu
“Advanced Menu”
SK 100G3 SKM 100G3
SKP 100 G3
Display Function of the menu item
Main menu “Menu”
Sensitivity Adjusts the sensitivity “AF
Frequency Preset Changes the frequency bank and the channel
Name Enters the transmitter name
Auto Lock Activates/deactivates the automatic lock mode
Advanced Calls up the extended menu “Advanced Menu
Exit Exits the operating menu and returns to the current standard display
Extended menu “Advanced Menu”
Tune Sets the transmission frequencies for the frequency bank “U
Sets a channel and a transmission frequency for the frequency bank “U
̈ Select this menu item and call it up by pressing the SET button (SK, SKP)/the
multi-function switch (SKM) until the channel selection appears.
Mute Mode (SK, SKP only) Sets the mode for the MUTE switch
Cable Emulation (SK only) Emulates guitar cable capacities
Pilot Tone Activates/deactivates the pilot tone transmission
LCD Contrast Adjusts the contrast of the display panel
Reset Resets the transmitter
Software Revision Displays the current software revision
Exit Exits the extended menu “Advanced Menu” and returns to the main menu
ew 100 P G3 Set _529660_0309_Sp9.book Seite 25 Mittwoch, 8. April 2009 6:57 18
Synchronizing transmitters with diversity receivers
26
Synchronizing transmitters with diversity receivers
When synchronizing transmitters with diversity receivers, please observe the following:
Upon delivery, transmitter and diversity receiver are synchronized with each other. If,
however, you cannot establish a transmission link between transmitter and diversity
receiver, you have to synchronize the channels of the devices:
̈ Deactivate the RF signal on all transmitters (see page 21).
This prevents that, during the frequency scan, the channels used by switched-on trans-
mitters are displayed as “used”.
̈ With a diversity receiver, perform a frequency preset scan to scan the frequency banks
for unused channels (“Scan New List”, see page 24).
̈ Select a frequency bank and a channel on this diversity receiver (“Current List”, see
page 24).
If you want to set up a multi-channel system, select a frequency bank with a sufficient
number of unused channels for all planned transmission links.
̈ Synchronize a transmitter with the diversity receiver (see page 19).
The receiver’s frequency, name and pilot tone setting are transferred to the transmitter.
OR:
̈ Manually set the transmitter to the same frequency bank and channel that you set on the
receiver.
̈ Activate the RF signal on the transmitter.
The transmission link is established.
If you want to set up a multi-channel system:
̈ Repeat the following 4 steps for each additional transmission link:
Perform a frequency preset scan with the next diversity receiver.
Select a channel from the same frequency bank as with the first diversity receiver.
Synchronize a transmitter with the diversity receiver.
Activate the RF signal on the transmitter.
̈ Make sure that the desired frequencies are listed in the enclosed frequency
information sheet.
OR:
̈ Contact your Sennheiser partner who will be pleased to calculate intermodula-
tion-free frequencies for you.
̈ Make sure that the desired frequencies are approved and legal in your country
and, if necessary, apply for an operating license.
ew 100 P G3 Set _529660_0309_Sp9.book Seite 26 Mittwoch, 8. April 2009 6:57 18
Synchronizing transmitters with diversity receivers
27
Using freely selectable frequencies
You can also freely select the receiving frequencies and store these frequencies in the
frequency banksU”.
̈ Set each diversity receiver to the frequency bankU”.
̈ On one of the receivers, select a channel within this frequency bank and assign this
channel one of the calculated receiving frequencies (“Tune”, see page 24).
̈ Synchronize a transmitter with this receiver (see page 19).
OR:
̈ Manually set the transmitter to the same frequency bank and channel that you set on the
receiver.
̈ Repeat for the remaining transmitters and receivers as described above.
It might be that the freely selected frequencies are not intermodulation-free
If you use frequencies from the frequency bank “U”, it might be that the frequen-
cies are not intermodulation-free.
̈ Contact your Sennheiser partner who will be pleased to calculate intermodula-
tion-free frequencies for you (see www.sennheiser.com).
ew 100 P G3 Set _529660_0309_Sp9.book Seite 27 Mittwoch, 8. April 2009 6:57 18
Cleaning the devices
28
Cleaning the devices
̈ Use a cloth to clean the devices from time to time. Do not use any solvents or cleansing
agents.
SKM 100 G3
To clean the radio microphone’s sound inlet basket:
̈ Unscrew the upper sound inlet basket from the microphone head by turning it counter-
clockwise.
̈ Remove the foam insert.
̈ There are two ways to clean the sound inlet basket:
Use a cloth to clean the upper sound inlet basket from the inside and outside
or scrub with a brush and rinse with clear water.
̈ If necessary, clean the foam insert with a mild detergent or replace the foam insert.
̈ Dry the upper sound inlet basket.
̈ Dry the foam insert.
̈ Reinsert the foam insert.
̈ Replace the sound inlet basket on the microphone head and screw it tight.
You should also clean the contact rings of the microphone head from time to time:
̈ Wipe the contact rings of the microphone head with a cloth.
CAUTION! Liquids can damage the electronics of the devices!
Liquids entering the housing of the devices can cause a short-circuit and damage the
electronics.
̈ Keep all liquids away from the devices.
CAUTION! Liquids can damage the microphone head!
Liquids can damage the microphone head.
̈ Only clean the upper sound inlet basket.
ew 100 P G3 Set _529660_0309_Sp9.book Seite 28 Mittwoch, 8. April 2009 6:57 18
If a problem occurs ...
29
If a problem occurs ...
EK 100 G3
Problem Possible cause Possible solution
Diversity receiver cannot
be operated, “Locked
appears on the display
panel
Lock mode is activated Deactivate the lock mode (see page 20).
No operation indication Batteries are flat or accupack is flat Replace the batteries or recharge the accupack
(see page 10).
No RF signal Transmitter and receiver are not on the
same channel
Set the transmitter and receiver to the same
channel.
Synchronize the transmitter with the receiver
(see page 19).
Transmission range is exceeded Reduce the distance between receiver and
transmitter.
RF signal is deactivated (“RF Mute“) Activate the RF signal (see page 21).
RF signal available, no
audio signal, “MUTE
appears on the display
panel
Transmitter is muted Cancel the muting (see page 21).
Receiver’s squelch threshold is adjusted
too high
Reduce the squelch threshold setting on the
receiver (see page 24).
Transmitter doesn’t transmit a pilot tone Deactivate the pilot tone evaluation
(see page 24).
Audio signal has a high
level of background noise
Transmitter sensitivity is adjusted too
low
Adjust the transmitter sensitivity correctly
(“Sensitivity”, see page 25).
Audio signal is distorted Transmitter sensitivity is adjusted too
high
Adjust the transmitter sensitivity correctly
(“Sensitivity”, see page 25).
Receiver’s audio output level is adjusted
too high
Reduce the audio output level (“AF Out”, see
page 24).
No access to a certain
channel
During scanning, an RF signal has been
detected on this channel and the channel
has been locked
Set the transmitter operating on this channel to
a different channel and redo the frequency
preset scan (see page 24).
During scanning, a transmitter of your
system operating on this channel has not
been switched off
Switch the transmitter off and redo the
frequency preset scan (see page 24).
ew 100 P G3 Set _529660_0309_Sp9.book Seite 29 Mittwoch, 8. April 2009 6:57 18
If a problem occurs ...
30
SK 100/SKM 100/SKP 100 G3
If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions,
please contact your local Sennheiser partner for assistance. To find a Sennheiser partner in your country, search at
www.sennheiser.com under “Service & Support”.
Problem Possible cause Possible solution
Transmitter cannot be
operated, “Locked
appears on the display
panel
Lock mode is activated Deactivate the lock mode (see page 20).
No operation indication Batteries are flat or accupack is flat Replace the batteries or recharge the accupack
(see page 13).
No RF signal at the
receiver
Transmitter and receiver are not on the
same channel
Synchronize the transmitter with the receiver
(see page 19).
Set the transmitter to the same channel as the
receiver.
Transmission range is exceeded Reduce the distance between receiver and
transmitter.
RF signal is deactivated (“RF Mute“) Activate the RF signal (see page 21).
RF signal available,
no audio signal,
MUTE” appears on the
display panel
Transmitter is muted (MUTE) Cancel the muting (see page 21).
Receiver’s squelch threshold is adjusted
too high
Reduce the squelch threshold setting on the
receiver.
Transmitter doesn’t transmit a pilot tone Activate or deactivate the pilot tone transmis-
sion (see page 25).
Audio signal has a high
level of background noise
or is distorted
Transmitter’s sensitivity is adjusted too
low/too high
Adjust the input sensitivity (see page 25).
ew 100 P G3 Set _529660_0309_Sp9.book Seite 30 Mittwoch, 8. April 2009 6:57 18
Specifications
31
Specifications
System
In compliance with
Modulation wideband FM
Frequency ranges 516–558, 566–608, 626–668, 734–776,
780–822, 823–865 MHz (A to E, G, see page 3)
Frequencies 1,680 frequencies, tuneable in steps of 25 kHz
20 frequency banks, each with up to 12 factory-preset
channels
1 frequency bank with up to 12 user programmable
channels
Switching bandwidth 42 MHz
Frequency stability ±10 ppm (–10°C to +55°C)
Compander system Sennheiser HDX
Nominal/peak deviation ±24 kHz48 kHz
Pilot tone (frequency/deviation) 32.7665 kHz/±2 kHz
THD 0.9%
Temperature range 10°C to +55°C
EK 100 G3
Receiver principle adaptive diversity
Sensitivity
(with HDX, peak deviation)
< 1.6 μV for 52 dBA
rms S/N
Adjacent channel rejection typ. 65 dB
Intermodulation attenuation typ. 65 dB
Blocking 70 dB
Squelch Off, Low: 5 dBμV, Middle: 15 dBμV, High: 25 dBμV
Pilot tone squelch can be switched off
S/N ratio (1 mV, peak deviation) 60 dB
AF output voltage
(at peak deviation, 1 kHz AF) 3.5 mm jack socket: +11 dBu (mono, unbalanced)
Adjustment range of audio output level (“AF Out”) 42 dB, adjustable in steps of 6 dB
Power supply 2 AA size batteries, 1.5 V or BA 2015 accupack
Nominal voltage 2.4 V
Power consumption:
at nominal voltage
with switched-off diversity receiver
typ. 140 mA
25 μA
Operating time typ. 8 hrs
Dimensions approx. 82 x 64 x 24 mm
Weight (incl. batteries) approx. 120 g
Europe
USA
EMC EN 301489-1/-9
Radio EN 300422-1/-2
Security EN 60065
47 CFR 15 subpart B
ew 100 P G3 Set _529660_0309_Sp9.book Seite 31 Mittwoch, 8. April 2009 6:57 18
Specifications
32
Approved by
SK 100/SKM 100/SKP 100 G3
Canada Industry Canada RSS 123
IC 2099A-G3EK100
limited to 806 MHz
RF output power at 50 Ω typ. 30 mW
Pilot tone squelch can be switched off
AF frequency response
SK microphone: 80–18,000 Hz
line: 25–18,000 Hz
SKM/SKP 80–18,000 Hz
Signal-to-noise ratio (1 mV RF, peak deviation)
SK/SKM/SKP 110 dBA
Max. input voltage (SK) microphone/line 3 V
rms
Max. input voltage (SKP) 3.3 V
rms
Input impedance SK microphone/line 40 kΩ, unbalanced/1 MΩ
Input impedance SKP 60 kΩ, unbalanced
Input capacitance SK switchable
Adjustment range of input sensitivity SK: 60 dB, adjustable in steps of 3 dB
SKM, SKP: 48 dB, adjustable in steps of 6 dB
Power supply 2 AA size batteries, 1.5 V
or BA 2015 accupack
Nominal voltage 2.4 V
Current consumption
at nominal voltage typ. 180 mA
with switched-off transmitter 25 μA
Operating time typ. 8 hrs
Dimensions SK: approx. 82 x 64 x 24 mm
SKM: approx. 50 x 265 mm
SKP: approx. 105 x 43 x 43 mm
Weight (incl. batteries) SK: approx. 160 g
SKM: approx. 450 g
SKP: approx. 195 g
ew 100 P G3 Set _529660_0309_Sp9.book Seite 32 Mittwoch, 8. April 2009 6:57 18
Specifications
33
In compliance with (SK, SKM and SKP 100 G3)
Approved by (SK, SKM and SKP 100 G3)
Microphones (SK 100 G3)
MMD 835-1 microphone head (SKM 100 G3)
Polar diagram and frequency response curve of the MMD 835-1 microphone head (SKM 100 G3)
Europe
EMC EN 301489-1/-9
Radio EN 300422-1/-2
Security EN 60065, EN 62311 (SAR)
SK 100 G3 SKM 100 G3 SKP 100 G3
Canada Industry Canada RSS 123,
IC: 2099A-G3SK
limited to 806 MHz
Industry Canada RSS 123,
IC: 2099A-G3SKMEM
limited to 806 MHz
Industry Canada RSS 123,
IC: 2099A-G3SKP
limited to 806 MHz
USA FCC-Part 74,
FCC-ID: DMO G3SK
limited to 698 MHz
FCC-Part 74,
FCC-ID: DMO G3SKMEM
limited to 698 MHz
FCC-Part 74,
FCC-ID: DMOG3SKP
limited to 698 MHz
For accessories and information on connector assignment, visit the ew G3 product page at www.sennheiser.com.
ME 2 ME 4
Microphone type condenser condenser
Sensitivity 20 mV/Pa 40 mV/Pa
Pick-up pattern omni-directional cardioid
Max. SPL 130 dB SPL 120 dB SPL
MMD 835-1
Microphone type dynamic
Sensitivity 2.1 mV/Pa
Pick-up pattern cardioid
Max. SPL 154 dB SPL
Polar diagram MMD 835-1 Frequency response curve MMD 835-1
0
5
10
15
20
25
dB
30°
30°
60°
60°
90°
90°
120°
150°
120°
150°
0°
180°
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
16000 Hz
Hz
100 1.000 10.000
dBV
-30
-40
-50
-60
-70
-80
50 100 200 500 1k 2k 5k 10k 20k
ew 100 P G3 Set _529660_0309_Sp9.book Seite 33 Mittwoch, 8. April 2009 6:57 18
Manufacturer Declarations
34
Manufacturer Declarations
Warranty
Sennheiser electronic GmbH & Co. KG gives a warranty of 24 months on this product.
For the current warranty conditions, please visit our web site at www.sennheiser.com or
contact your Sennheiser partner.
In compliance with the following requirements
RoHS Directive (2002/95/EC)
WEEE Directive (2002/96/EC)
Please dispose of these products at the end of their operational lifetime by taking
them to your local collection point or recycling center for such equipment.
Battery Directive (2006/66/EC)
The supplied batteries or rechargeable batteries can be recycled. Please dispose of
them as special waste or return them to your specialist dealer. In order to protect
the environment, only dispose of exhausted batteries.
R&TTE Directive (1999/5/EC)
The declarations are available at www.sennheiser.com.
Before putting the devices into operation, please observe the respective country-specific
regulations.
CE Declaration of Conformity
EK 100 G3: SK / SKM / SKP 100 G3:
0682
0682
ew 100 P G3 Set _529660_0309_Sp9.book Seite 34 Mittwoch, 8. April 2009 6:57 18
Manufacturer Declarations
35
Statements regarding FCC and Industry Canada
These devices comply with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions: (1) these devices may not cause harmful
interference, and (2) these devices must accept any interference received, including inter-
ference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment gener-
ates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
These class B digital devices comply with the Canadian ICES-003.
Changes or modifications made to this equipment not expressly approved by Sennheiser
electronic Corp. may void the FCC authorization to operate this equipment.
Before putting the devices into operation, please observe the respective country-specific
regulations!
ew 100 P G3 Set _529660_0309_Sp9.book Seite 35 Mittwoch, 8. April 2009 6:57 18
Sennheiser electronic GmbH & Co. KG
Am Labor 1, 30900 Wedemark, Germany
www.sennheiser.com
Printed in Germany
Publ. 01/09
529660/A01
C
M
Y
CM
MY
CY
CMY
K
37

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sennheiser EK 100 G3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info