Installation instructions for trained electricians only
5 Variant 1
Install bench sensor FII
Figures 5 7
Install the bench sensor in the sauna cabin about 15
cm below the ceiling and opposite of the heating sys-
tem.
The bench sensor with its overtemperature fuse may
only be connected with the supplied 150° C tempera-
ture-resistant connecting line or an equivalent tempe-
rature-resistant line.
On the outside of the sauna cabin, the temperature-
resistant connecting line can be extended with custo-
mary lines.
WARNING - Electric shock:
Run the power cables separate to other sen-
sor and control lines.
Protect single insulated lines with a pipe
(double insulation).
1. Run line 5 to mounting location of bench sensor
4 in the cabin wall and fix in position with wiring
clips.
2. Separate two half shells 1 of bench sensor 4
and connect two terminals of the up to 150° C
temperature-resistant line according to circuit dia-
gram 7.
3. Insert round adapter plate 2 with the connections
crosswise in half shells 1, close half shells 1
and fix with the two 9 mm long Philips head screws
3.
Check for secure fit of bench sensor 4.
4. Conduct tests according to the chapter “Tests”.
5 Fix bench sensor 4 to the cabin wall opposite of
the heating system with two wood screws 6
keeping a distance of 15 cm to the ceiling.
4 Installing the stove sensor FI
with overtemperature fuse
Figures 4 7
Install the stove sensor with overtemperature fuse in
the sauna cabin about 15 cm below the ceiling and
above the heating system, or in accordance with the
cabin manufacturer's specifications.
Use only the supplied 150° C temperature-resistant
connecting line or an equivalent temperature-resistant
line to connect the stove sensor with overtemperature
fuse.
On the outside of the sauna cabin, the temperature-
resistant connecting line can be extended with conven-
tional lines.
WARNING - Electric shock:
Run the power cables separate to other sen-
sor and control lines.
Protect single insulated lines with a pipe
(double insulation).
1. Run four-pin line 5 to mounting location of sto-
ve sensor 4 in the cabin wall and fix in position
with wiring clips.
2. Separate two half shells 1 of stove sensor 4
and connect four terminals of the temperature-re-
sistant line according to the circuit diagram 7
(observe the color coding on the sensors which
correspond to the figures).
3. Insert round adapter plate 2 with the connections
crosswise in half shells 1, close half shells 1
and fix with the two 9 mm long Philips head screws
3.
Check for secure fit of stove sensor 4.
4. Conduct tests according to the chapter “Tests”.
5. Bolt stove sensor 4 to the cabin wall in alignment
with the heater, keep a distance of 15 cm to the
ceiling, or install in accordance with the cabin
manufacturer's specifications, using two wood
screws 6.
35

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sentiotec CK 3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info