663262
1
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
MV#:20170307 15:53
Optional: Sensor settings (only for articles:
800501 and 800503)
1-2 3-4 5-6 7-8
DIP switch: ON = 1 / OFF = 0
1-2 - Detection range:
3-4 - Time setting:
5-6 - Light sensitivity activation:
7-8 - No function
Detection range overview (diameter)
h
IV
III
II
I
Detection range setting (sensitivity)
1 2 Ø
h
I
100%
~
6,0m
II
75%
~
4,5m
III
50%
~
3,0m
IV
25%
~
1,5m
1-2
Time setting
duration of light after detection
3 4
I
5s
II
90s
III
3min
IV
10min
3-4
Light sensitivity activation
The lower lux is programmed, the darker it must
be to switch on the ceiling light
5-6
5 6
I
24 h
II
50 lux
III
15 lux
IV
5 lux
Installation and Operating Manual
Art Nr.
800500 800501 800502 800503
Power
15W
Input voltage
230V AC
LED Lumen output
1.260 1.260 1.200 1.200
Color temp.
4.000K 4.000K 3.000K 3.000K
Microwave Sensor
No yes - 5,8 GHz No yes - 5,8 GHz
Lifespan
20.000 hours
Dimensions
Ø350 x 100mm
Ambient Temp. (T)°C
-10 T 40
General safety instructions
Please read the operating instructions for the
LED ceiling light before use. The operating in-
structions are part of the product. They contain
important notes on start-up and handling of the
device. Always keep the enclosed operating ins-
tructions so as to be able to look up information.
They must be enclosed when passing the device
on to third parties.
Safety precautions
The user must observe the safety notes and
warnings in order to maintain this status and to
ensure safe operation. Please read the operating
instructions before start up.
Avoid contact with high temperatures or vibra-
tions, this may cause damage to the ceiling light.
Do not immerse the enclosure into water.
Never attempt to open the device other than de-
scribed in this manual. The LED ceiling light can-
not be repaired; this part must be immediately
disposed in case of a defect. Ensure sufcient
ventilation of the device. Never cover it during
operation. Do not install in reach of children or
animals.
Any other use of the device than described above
can damage the product or endanger the user
due to e. g. short-circuits, re or an electric
shock. The entire product may not be modied
or adapted. Don’t touch the ceiling light while in
use or after use until it’s cooled down. The ceiling
light must have an earthed connection for safe
operation.
These safety notes must be observed in all ca-
ses! Any warranty claim is void in the case of
damages caused by non-observance of these
operating instructions. We are not liable for con-
sequential damages or for damages to property
or persons caused by non-observance of the sa-
fety notes and improper operation of the device.
Safe operation is not possible anymore, if:
- the LED ceiling light has visible damages,
- the LED ceiling light does not work anymore
Installation instructions
Notes on Disposal
Old units, marked with the symbol as il-
lustrated, may not be disposed of in the
household rubbish.
You must take them to a collection
point for old units (enquire at your local
authority) or the dealer from whom you bought
them. These agencies will ensure environmen-
tally friendly disposal.
Care and warranty
Before cleaning the unit, disconnect it if neces-
sary from other components; do not use aggres-
sive cleaning agents.
The unit has been carefully checked for defects.
If nevertheless you do have cause for complaint,
please go back to the retailer where you have
bought the product together with your proof of
purchase. We offer a 2 year warranty from date
of purchase. We are not liable for damage arising
from incorrect handling, improper use or wear
and tear. We reserve the right to make technical
modications.
Visit us online at www.shada.nl for more infor-
mation about our products and our company.
CE declaration
This product is compliant with directives:
2014/35/EU, 2014/30/EU
2011/65/EU
800501/800503 Additional:
R&TTE: 1999/5/EC
Declaration of conformity available under:
http://www.shada.nl/uploads/DoCs/index.html
WEEE NL: 3505
WEEE DE: 37281017
WEEE AT: 40133
Imported by
Kanaal Noord 350
NL-7323 AM Apeldoorn
www.shada.nl
LED‘s light
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Shada 800503 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info