515977
5
Zoom out
Zoom in
Vorherige Seite
1/132
Nächste Seite
ENGLISH
INDOOR TEMP. OUTDOOR TEMP.
COOLING
upper limit
32˚C D.B. 43˚C D.B.
23˚C W.B. -
lower limit
21˚C D.B. 21˚C D.B.
15˚C W.B. -
HEATING
upper limit
27˚C D.B. 24˚C D.B.
- 18˚C W.B.
lower limit
20˚C D.B. -8.5˚C D.B.
- -9.5˚C W.B.
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
The built-in protective de-
vice may prevent the unit
from operating when used
out of this range.
Condensation may form on
the air outlet if the unit op-
erates continuously in the
COOL or DRY mode when
humidity is over 80 percent.
D.B. = Dry-bulb W.B. = Wet-bulb
NOTES FOR MODELS AY-X08CR/AY-X10CR/AY-X13CR
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent
cold air from blowing out of the unit.
DE-ICING FUNCTION
When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer
provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop
operating.
After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
HEATING EFFICIENCY
The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside
air temperature therefore greatly affects the heating efficiency.
If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
It takes time to warm up and heat the entire room because of the forced air circulation system.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
SET THE CORRECT TEMPERATURE
Setting the thermostat 1°C higher than the desired temperature in the COOL mode (and 2°C lower in the
HEAT mode with models AY-X08CR/AY-X10CR/AY-X13CR) will save approximately 10 percent in power
consumption.
Setting the temperature lower than necessary during cooling operation will result in increased power
consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
Blocking direct sunlight during cooling operation will reduce power consumption.
Close the windows and doors during cooling opeation (and heating operation with models AY-X08CR/AY-
X10CR/AY-X13CR).
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR
CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION
MAKE MOST OF THE TIMER OFF FUNCTION
DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN
EXTENDED PERIOD OF TIME
The indoor unit still consumes a small amount of power when it is not operating.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re-start in the same settings which were active before the power
failure, except for timer settings.
If the timers were set before a power failure, they will need to be re-set after power recovery.
(AY-X08CR/AY-X10CR/
AY-X13CR only)
E-3
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sharp AE-X10CR wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info