Connecting the appliance
Have a technician install and connect the appliance
according to the enclosed installation instructions.
Do not remove the transportation protection devices
from the shelves and storage compartments until
the appliance has been installed.
Always connect the water before the power.
Apart from statutory national regulations, you should
stick to the connection terms relating to the local
electricity and water companies.
After installing the appliance, wait at least 1 hour until
the appliance starts up. During transportation the oil
in the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
“Cleaning the appliance”).
Water connection
The water may be connected only by a competent fitter
according to the local regulations of the appropriate
water supply company.
m Caution
Risk of appliance being damaged by particles!
The water filter must always be connected to the tap –
even if an additional filter system is used.
m Caution
Use only the enclosed hose set or a hose set
purchased from customer service for connection to the
drinking water mains.
The hose set must only be installed by customer
service.
Do not use existing or already used hose sets.
Connect the appliance to a drinking water line only:
ʋ Minimum pressure: 0.2 Mpa (2 bar)
ʋ Maximum pressure: 0.8 Mpa (8 bar)
ʋ Pressure over 0.8 MPa (8 bar): install a pressure
limiter between drinking water connection and hose
set
A separate shut-off valve should be installed
in the cold-water inflow.
The shut-off valve should not be located behind
the appliance. It is recommended that you mount
the shut-off valve directly next to the appliance or at
another place which is easily accessible.
When installing the water connection, pay attention
to the permissible installation area for the water mains.
For connection to the drinking water mains use only
water pipes which are suitable for drinking water.
Observe national regulations and the connection
conditions of the local water supply companies.
Note
The maximum outside diameter of the water mains
(without connecting pieces) is 10 mm.
Electrical connection
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with the protection class I.
Connect the appliance to 220-240 V/50 Hz alternating
current via a correctly installed socket with protective
conductor. The socket must be fused with a 10
to 16 A fuse.
For appliances operated in non-European countries,
check whether the stated voltage and current type on
the rating plate match the values of your mains supply.
These specifications can be found on the rating plate
(see chapter “Customer service”).
m Warning
Never connect the appliance to electronic energy saver
plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters are used
for photovoltaic systems which are connected directly
to the national grid. Sine-controlled inverters must be
used for isolated applications (e.g. on ships or in
mountain lodges) which are not connected directly to
the national grid.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Siemens CI 30 RP 00 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Siemens CI 30 RP 00

Siemens CI 30 RP 00 Bedienungsanleitung - Deutsch - 22 seiten

Siemens CI 30 RP 00 Bedienungsanleitung - Holländisch - 40 seiten

Siemens CI 30 RP 00 Bedienungsanleitung - Französisch - 25 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info