Water Connection (page III / IV, diagrams 10 to 12)
Only detachable connections are permissible!
Before connecting the fittings, thoroughly flush out the water pipes in order to remove any impurities.
For closed operations, if the safety valve is not directly above the drain, then the drain pipe must be mounted at a continuous
downward slope in a frost-free environment.
Please take care because of application range within water types according to technical data on page 17.
Operating Modes
Single Power Operation
Connection without off-peak contact.
The appliance heats with the adjusted performance.
The 'fast-heating' button is only used for the reset and diagnose functions.
Connection with off-peak contact
If the 'fast-heating’ button is activated, the device heats once to the configured temperature. All 6 LED thermal capacity
indicators light up as soon as the configured temperature has been reached. Afterwards, the device turns itself off
automatically.
Double Power Operation
Connection without off-peak contact.
The reservoir heats with the configured basic performance.
The “fast-heating function” activates a heating cycle at higher installed power in order to accelerate the heating-up procedure.
To start this function, press the fast-heat button . The LED fast-heating' lights up. The function turns itself off auto-
matically, as the soon as the configured temperature has been reached. The LED 'fast-heating' turns off .
Connection with off-peak contact
During off-peak time the device heats with the configured basic performance. The “fast-heating function” activates a heating
cycle at higher power in order to accelerate the heating-up procedure. To start this function, press the fast-heat button . The
LED 'fast-heating' lights up. The function turns itself off again automatically as soon as the configured temperature has
been reached. The LED fast-heating' turns off.
The rest of the time, the device does not heat. If the 'fast-heating' button is activated, the device heats once to the config-
ured temperature. All 6 LED thermal capacity indicators light up as soon as the configured temperature has been reached.
Afterwards, the device turns itself off automatically.
Boiler Mode
Connection without off-peak contact.
The device does not heat by default.
If the 'fast-heating' button is activated, the device heats once to the configured temperature. All 6 LED thermal capacity
indicators light up as soon as the configured temperature has been reached. Afterwards, the device turns itself off
automatically.
Each further heating process must be started by pushing the button “fast-heating” .
Electrical Connections
Danger of electric shock!
The power switch “S1” may only be activated in an unpowered state!!
Remove lower cap by taking the screws out (page IV, diagram 13, 13.1).
Lead cable through the cable gland and cord grip and connect, then tighten the cable gland and cord grip (page V, diagram
14).
Check that the system is suitable for the maximum power absorbed by the water heater (please refer to the data plate) and that
the cross-section of the electrical connection cables is suitable, and no less than 2.5 mm
2
.
Operating mode
Set the power switch “S1” to the correct operating mode on the electronic board.
Set the desired load according to the connection examples.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Siemens DG12025 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info