IV.
Electrical connection
As a matter of principle, the water connections must be
completed first of all before the heater is connected to the
electricity supply. The appliance should be wired up ac-
cording to the circuit diagram on the inside of the cover.
Circuit as delivered:
12 kW Y 400 V 3 ~ (11 kW Y 380 V 3 ~)
Connection Options:
8.0 kW 230 V ~ (7.4 kW 220 V ~)
6.0 kW 230 V ~ (5.5 kW 220 V ~)
(The required optional bridge can be found under
accessories.)
To guarantee compliance to relevant safety regulations,
an all-pole separator must be fitted during installation.
The contact opening must be at least 3 mm.
Terminal BZ45Z20M (special accessories) can be used
if the connecting cable is fed into the continuous-flow
heater via one of the bottom holes 14a!
The wires must not interfere with the operation of release
button A on the safety temperature limiter.
Connection Options (Fig. A)
Definitiv wiring diagram in the appliance:
f1 Safety temperature limiter with mains terminals 1-3-5
l2 Change-over terminal strip
(The required optional bridge for the
6 kW 230 V ~/5.5 kW 220 V ~ circuit can be found under
accessories.)
Installation note
The installation of non plug-in ready appliances must be
undertaken by the respective utility operator or by a quali-
fied specialist company, who can also assist you when
you are requesting the approval of the utility company for
installation of the appliance.
V.
Mounting the cover onto the heater
VI.
Startup
The device is compliant to IEC 61000-3-12.
Switch on via the heater fuses in the domestic wiring.
Turn on the hot water tap and check the water temperature.
Explain the appliance to the user and please give him the
operating instructions.
Priority switch for combination with electric storage
heaters (Fig. A)
If the heater is going to be operated in this way, a priority
switch must be connected into the line connecting the L2
phase to the appliance. It should be mounted on the meter
or distribution panel.
a, b Control line for the electricity supply company con-
nected to the coil input on the charging contactor
f1 Safety temperature limiter with mains terminals
f3 Priority switch (current relay)
Specifications
DH12103M
Rated power as delivered [kW] / Rated voltage
Connection Options
12 kW Y 400 V 3 ~ (11 kW Y 380 V 3 ~)
8.0 kW 230 V ~ (7.4 kW 220 V ~)
6.0 kW 230 V ~ (5.5 kW 220 V ~)
Switch-on point [I/min]
3.6
Mixed water [I/min] at rated power
approx. 38 °C 6.5
approx. 50 °C
(supply temperature 12 °C)
4.4
Minimum flow pressure of appliance* [MPa (bar)]
with flow limiter 0.3 (3)
without flow limiter 0.2 (2)
Energy efficiency class
A
Load profile
XS
Annual energy consumption [kWh]
474
Daily energy consumption [kWh]
2.178
Sound power level [dB]
15
Hot water heating energy efficiency [%]
38.9
* Plus any pressure loss at the tap mixer
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Siemens DH12103M wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info