CE1B3076.2en / 25 Feb 2010 Subject to change Siemens Building Technologies
s
Operating Instructions
RDF400...
RDF400... – the room thermostat that allows you to set the ideal room temperature.
The thermostat provides Comfort, Energy Saving, and Protection mode and can operate in Auto timer mode using
8 programmable time schedules.
The fan operates either in Auto mode or at a speed selected in Manual mode.
You can either take advantage of the thermostat's factory settings or adjust it as needed.
Display
Protection mode
Auto Timer mode
Comfort mode
Energy Saving mode
Measured room temperature,
setpoints and parameters
Current time of day
Actual room temperature
Fault indicator *
Condensation in the room *
Cooling demand / mode
Heating demand / mode
Electrical heater active
Automatic fan
Low fan speed
Medium fan speed
High fan speed
Buttons are locked
Weekday 1…7
(1 = Monday / 7 = Sunday)
Operation and settings
Operating mode button
** **
View and set
Auto-Timer-Programm
Protection mode / system ON
Colder / Warmer
Fan mode button
– Automatic fan (
)
– Manual fan (
)
Set time of day and weekday
Confirm settings
* Needs to be configured by your HVAC installer
** Needs to be enabled via parameter P02
Change room temperature
+ / –
Press + or to increase or decrease the current room temperature setpoint for
Comfort mode. The thermostat changes to Comfort
.
The setting range is 5...40 °C, unless limited by parameters P09 and P10.
Adjust fan speed / fan mode
Press the button until you reach the desired fan mode.
In Auto mode, the thermostat automatically selects the fan speed based on set-
point and actual room temperature. The fan continues to run at low speed
(factory setting) after the room temperature reaches the setpoint .
In manual mode, the fan always runs at the speed that you select:
Low fan speed
Medium fan speed
High fan speed
For a single-speed fan, you can change the mode between and .
Change thermostat operating
Press operating mode button
to change the operating mode display.
In protection mode, the plant stops operating. However, if the room temperature
drops below 8 °C, heating is switched on to protect the room against frost.
Your HVAC installer can change the frost protection limit and set a heat pro-
tection limit as needed:
Changes made by installer: Frost protection: ........... ˚C
Heat protection: ........... ˚C
In Comfort mode, the thermostat maintains the room temperature on the set-
point which can be readjusted using the + and – buttons.
In Energy Saving mode, the room temperature is maintained at a lower or higher
setpoint, thus saving energy and money.
Adjust parameters P11 and P12 to change the preselected setpoints.
The thermostat can be set to Energy Saving mode either by pressing the ope-
rating mode button if enabled (P02 = 2), or via an external signal (switch) such
as window contact, keycard or presence detector.
In Auto timer mode, the thermostat automatically switches between Comfort
and Energy Saving mode according to the time schedule.
Change from heating to cooling mode
/
Changeover between cooling and heating is either automatic using a heating /
cooling changeover sensor or a remote changeover switch, or manual by
pressing the operating mode button
. No changeover is possible if the
thermostat is configured for cooling only or heating only, (see parameter P01).
Display for automatic changeover or heating only / cooling only:
Heating valve is open
Cooling valve is open
Display for manual changeover:
Thermostat is in heating mode
Thermostat is in cooling mode
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Siemens RDF400 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Siemens RDF400

Siemens RDF400 Bedienungsanleitung - Deutsch - 2 seiten

Siemens RDF400 Installationsanweisung - Alle Sprachen - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info