Operating instructions
REV34.. - 7-day room temperature controller for the right temperature at the right time. All factory
settings already provide optimal living comfort. You can easily adjust the controller to your needs
with the user-assisted clear-text display and program selection slider.
Note the following for placing the controller:
Make sure no other influencing factors influence the controller's temperature sensor (no solar radiation and
other heat or cold source influences).
Day of week
Low battery
Radio clock Date Setting: 1-5, 6-7, 1..7
active Reading: 1..7
Time display
Remote control active
Holiday mode
Display
Info mode
Installer mode
Temperature
setpoint icons
Text display
Alarm
Heating mode
Switching pattern
with time cursor
Temperature display
Automatic mode
Party mode active
Exception day mode
Continuous comfort mode
Actuator / Valve closes
Continuous energy
saving mode
Actuator / Valve opens
°C or °F
Frost protection mode
Info button
Increase values, set time or
make a selection
Change between Comfort and
energy saving temperature
(active until next switching time)
and Party function
Decrease values, set time or
make a selection
Operating mode
selector:
- Automatic
- Exception day
- Comfort mode
- Energy saving
mode
- Frost
protection
mode
Program selection slider
RUN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Operating elements and settings
Time setting
D
a
t
e
Day / Month /
Year
Weekdays 1-5
Weekend 6-7
Individual da
y
s 1..7
1, 2 or 3
Comfort phases
Start time
Comfort phase 1
Temperature
Comfort phase 1
End
Comfort phase 1
Start time
Comfort phase 2
Temperature
Comfort phase 2
End
Comfort phase 2
Start time
Comfort phase 3
Temperature
Comfort phase 3
End
Comfort phase 3
Saving temp. time
program
Start
Absence
Temperature
Absence
End
Absence
Temperature
remote control
Slider positions
If the selected operating mode does not support the setting, the time display shows PASS.
Special symbols displayed
The controller display can show the following special symbols:
Is symbol displayed ?
The alarm indicates an error!
Press the Info button and check the error message (e.g. radio clock signal, radio connection to receiver, etc.).
Contact a specialist as needed.
Is symbol displayed ?
This symbol tells you that you must exchange the batteries within the next 3 months.
Insert 2 new alkaline batteries type AA, 1.5 V as follows:
Remove the controller from the mounting base; open the battery compartment on the rear; remove the old
batteries; insert the new batteries and reinsert the controller in the base.
Caution: Time and date are retained for max. 1 minute.
(All other settings are fixed and remain unchanged!)
Dispose of the batteries as per regulations.
Is symbol displayed ?
The radio clock symbol only appears if the receiver is set up and activated to receive the
time signal from Frankfurt (Germany). A permanent symbol indicates that both time and
date of the controller are synchronized to Frankfurt (DCF77).
The symbol flashes if the signal is not received for more than 1 week.
Is symbol displayed ?
The controller is in heating mode .
Commission the controller and quick start
The controller contains a factory-set heating switching pattern and temperature values.
Proceed as follows for initial commissioning:
Remove the controller from the mounting base and pull off the black insulating
tape from the 2 batteries: The controller turns on automatically.
Important: Reinsert the controller in the mounting base
immediately
. During commissioning, the controller
synchronizes the 3-way valve during the first 180 seconds.
After startup, a welcome message appears for ca. 2 minutes. Press a button
to interrupt the message. Language selection starts with “ENGLISH“ (factory
setting). Press
or until your language appears. Press or move
the slider to accept your language.
Slider in position 1 (time setting): Press or to set the time.
Note: You do not need to enter the time when DCF77 receiver for the
time signal from Frankfurt (Germany) is equipped.
Slider in position 2 (date: day/month/year): Press
or to set the date.
Note: You do not need to enter the date when DCF77 receiver for the
time signal from Frankfurt (Germany) is equipped.
RUN
Move the slider to the very right to position RUN (only way to close the cover).
Set the operating mode with the operating mode selector.
Factory setting is
.
Fold the operating instructions and reinsert in the mounting base.
Turn on display lighting, check error messages or other important
information
Press the Info button once to activate display backlighting. Backlighting
goes off automatically after a short time.
Continuing to press the Info button activates the information display:
is lit. The device first shows pending error messages and then important
information (e.g. switching programs, ...).
Change the temperature level in the time switch program, or are you
not at home for a while?
In the time switch program, press this button to change from the current
temperature level to the next and back.
Quickly activate energy saving temperature when you leave the apartment
briefly to save energy.
The change appears on the display. It is valid only until the next switching
time.
Tips to save energy without reducing comfort
Heat your rooms to max 21 °C.
Use
to switch to energy saving temperature even if you are absent only briefly.
Air out your rooms briefly, but with wide-open windows.
B2208en 20.03.2008 Siemens, Building Technologies
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

siemens-rev34

Suche zurücksetzen

  • Ich möchte die simens rev34 auf deutsch einstellen Eingereicht am 19-3-2023 11:49

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Siemens REV34 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Siemens REV34

Siemens REV34 Bedienungsanleitung - Deutsch - 2 seiten

Siemens REV34 Bedienungsanleitung - Holländisch - 2 seiten

Siemens REV34 Bedienungsanleitung - Französisch - 2 seiten

Siemens REV34 Installationsanweisung - Alle Sprachen - 50 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info