- check the tight seating of the accessory (incorrect
or not securely fastened accessories can come loose
during operation and create a hazard)
Mounting of sanding sheet 5
- knock the dust out of the VELCRO material on sanding
pad C 2 before mounting the sanding sheet
- mount VELCRO sanding sheet as illustrated
! the dust suction requires the use of perforated
sanding sheets
! perforation in sanding sheet should correspond
with perforation in sanding foot
! replace worn sanding sheets in time
! always use the tool with the total VELCRO
surface covered with sanding paper
Dust/chip extraction 6
- mount dust extraction device D as illustrated
- connect vacuum cleaner
! do not use dust extraction device/vacuum cleaner
when sanding metal
- clean dust extraction device D regularly for optimal
dust pick-up performance
On/o
- switch on/o the tool by pushing switch E 2 in "I"/"O"
position
! before the accessory reaches the workpiece, the
tool should run at full speed
! before switching off the tool, you should lift it
from the workpiece
Adjusting working speed 7
- with wheel F the required oscillating frequency can be
adjusted from low (1) to high (6) (also while tool is
running)
- the optimal working speed depends on the material
and can be determined with practical trials
Holding and guiding the tool
! while working, always hold the tool at the
grey-coloured grip area(s) 8
- keep ventilation slots G 2 uncovered
- do not apply too much presssure on the tool
(excessive pressure will cause excessive heat and
may shorten the service life of the accessory)
APPLICATION ADVICE
Use segment saw blade H 2 for separating and plunge
cuts in wood, plaster, gypsum and plastics (also for
sawing close to edges, in corners and other hard-to-
reach areas)
Use plunge-cut saw blade J 2 for separating and deep
plunge cuts in ferrous and non-ferrous metals
Use plunge-cut saw blade K 2 for smaller separating
and plunge cuts in ferrous and non-ferrous metals
Use plunge-cut saw blade L 2 for separating and deep
plunge-cuts in wood, plaster, gypsum and soft plastics
(also for sawing close to edges, in corners and other
hard-to-reach areas)
Use plunge-cut saw blade M 2 for smaller separating
and plunge-cuts in wood, plaster, gypsum and soft
plastics
MAINTENANCE / SERVICE
Always keep tool and cord clean (especially ventilation
slots G 2)
! disconnect the plug before cleaning
If the tool should fail despite the care taken in
manufacturing and testing procedures, repair should be
carried out by an after-sales service centre for SKIL
power tools
- send the tool undismantled together with proof of
purchase to your dealer or the nearest SKIL service
station (addresses as well as the service diagram of
the tool are listed on www.skilmasters.com)
ENVIRONMENT
Do not dispose of electric tools, accessories and
packaging together with household waste material
(only for EU countries)
- in observance of European Directive 2012/19/EC on
waste of electric and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their life
must be collected separately and returned to an
environmentally compatible recycling facility
- symbol 9 will remind you of this when the need for
disposing occurs
DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product
described under “Technical data” is in conformity with the
following standards or standardization documents: EN
60745, EN 61000, EN 55014, in accordance with the
provisions of the directives 2004/108/EC, 2006/42/EC,
2011/65/EU
Technical file at: SKIL Europe BV (PT-SEU/ENG1),
4825 BD Breda, NL
05.09.2014
NOISE/VIBRATION
Measured in accordance with EN 60745 the sound
pressure level of this tool is 85 dB(A) and the sound
power level 96 dB(A) (standard deviation: 3 dB), and the
vibration (hand-arm method)
when surface grinding 4.1 m/s² (uncertainty K = 1.5 m/s²)
when cutting with plunge-cut saw blade 7.4 m/s²
(uncertainty K = 1.5 m/s²)
when cutting with segment saw blade 7.1 m/s²
(uncertainty K = 1.5 m/s²)
The vibration emission level has been measured in
accordance with a standardised test given in EN 60745; it
may be used to compare one tool with another and as a
preliminary assessment of exposure to vibration when
using the tool for the applications mentioned
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Skil 1490 - MULTI-FUNCTION TOOL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info