SAFETY INSTRUCTIONS FOR ANGLE GRINDERS
GENERAL
Only use this tool for dry grinding/cutting
Only use the flanges which are supplied with this tool
This tool should not be used by people under the age of
16 years
Always disconnect plug from power source before
making any adjustment or changing any accessory
ACCESSORIES
Use the original SKIL accessories which can be obtained
from your SKIL dealer
For mounting/using non-SKIL accessories observe the
instructions of the manufacturer concerned
Use only accessories with an allowable speed matching
at least the highest no-load speed of the tool
Do not use damaged, deformed or vibrating grinding/
cutting discs
Handle and store grinding/cutting discs carefully to avoid
chipping and cracking
Protect accessories from impact, shock and grease
Do not use a grinding/cutting disc that is larger than the
maximum recommended size
Only use grinding/cutting discs with a hole diameter
which fits mounting flange H 2 without play; never use
reducors or adaptors to fit large-hole grinding/cutting
discs
Never use grinding/cutting discs with a threaded hole, of
which the thread is not long enough to accept the spindle
length of the tool
Never use accessories with a "blind" threaded hole
smaller than M14 x 21 mm
OUTDOOR USE
Connect the tool via a fault current (FI) circuit breaker
with a triggering current of 30 mA maximum
Only use an extension cord which is intended for outdour
use and equipped with a splashproof coupling-socket
BEFORE USE
Before using the tool for the first time, it is recommended
to receive practical information
Do not work materials containing asbestos (asbestos
is considered carcinogenic)
Take protective measures when during work dust
can develop that is harmful to one's health,
combustible or explosive (some dusts are considered
carcinogenic); wear a dust mask and work with dust/chip
extraction when connectable
Be careful of hidden electrical wires or gas- and water
pipes; check the work area, for instance with a metal
detector
Be careful when cutting grooves, especially in supporting
walls (slots in supporting walls are subject to country-
specific regulations; these regulations are to be observed
under all circumstances)
Clamp the workpiece in case it does not remain
stationary from its own weight
Do not clamp the tool in a vice
Use completely unrolled and safe extension cords with a
capacity of 16 Amps (UK 13 Amps)
Wear protective glasses and gloves, hearing
protection 4, and sturdy shoes; when necessary, also
wear an apron
Always mount auxiliary handle F 2 and protective guard
G 2; never use the tool without them
Be sure tool is switched off when plugging in
DURING USE
Always keep the cord away from moving parts of the
tool; direct the cord to the rear, away from the tool
If the cord is damaged or cut through while working, do
not touch the cord, but immediately disconnect the plug;
never use the tool with a damaged cord
Push spindle-lock button D 2 only when spindle A 2 is
at a standstill
Keep hands away from rotating accessories
When grinding metal, sparks are generated; keep other
persons and combustible material from work area
In case of electrical or mechanical malfunction,
immediately switch off the tool and disconnect the plug
In case the cutting disc is blocked, resulting in jerking
forces on the tool, immediately switch off the tool
In case of current interruption or when the plug is
accidentally pulled out, unlock the on/off switch J 2
immediately and put it in the OFF-position in order to
prevent uncontrolled restarting
Do not apply so much pressure on the tool that it comes
to a standstill
AFTER USE
Before you put down the tool, switch off the motor and
ensure that all moving parts have come to a complete
standstill
After switching off the tool, never stop the rotation of the
accessory by a lateral force applied against it
WHEN CONNECTING NEW 3-PIN PLUG (U.K. ONLY):
Do not connect the blue (= neutral) or brown (= live) wire
in the cord of this tool to the earth terminal of the plug
If for any reason the old plug is cut off the cord of this
tool, it must be disposed of safely and not left unattended
TOOL ELEMENTS 2
A Spindle
B Clamping flange
C Accessory key
D Spindle-lock button
E Spanner (9140)
F Auxiliary handle
G Safety guard
H Mounting flange
J On/off locking switch
K Second on/off locking switch (9240/9245)
L Ventilation slots
USE
Mounting of accessories 5
! disconnect the plug
- clean spindle A and all parts to be mounted
- tighten clamping flange B with key C while pushing
spindle-lock button D (9146/9240/9245)
- tighten clamping flange B with key C while locking
spindle with spanner E (9140)
7
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Skil 9140 aa wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info