Admin and Installation Guide M900 Description of Settings
Setting Description
System combination (number
of base stations/repeaters
per base station)
Three settings are available.
Note: The conguration must be set at the time the multicell system is
congurated. It cannot be modied:
50/3: 50 base stations and 3 repeaters
127/1: 127 base stations and 1 repeater
254/0: 254 base stations and 0 repeater
Base Station Group (Fig. 2)
ID Base station identity in the chained network. Automatically assigned
consecutively when new base stations are added to the chain. With checkbox
for selection for removal from chain.
Permitted output: Positive integers.
RPN The Radio Fixed Part Number is an 8-bit DECT cell identity allocated by the
installer. The allocated RPN within the SME must be geographically unique.
Permitted output: 0 to 255 (DEC) or 0x00 to 0xFF (HEX)
Version Current rmware version on base station.
Permitted output: Positive integers with dot (e.g, 355.21).
MAC address The media access control (MAC) address is a unique identier assigned by the
manufacturer. Printed on device's label and on Home page of web interface.
IP address The Internet Protocol address assigned by the network the base station is
located in.
IP status Current base station status in the SME network.
This unit: Indicates that you are looking at this base station's web interface.
Connected: The base station is online in the network.
Connection lost: The connection to the base station has been lost.
DECT sync source The drop-down menu contains the RPNs of each of the currently connected
base stations followed (in parentheses) by the strength of the respective radio
signal (RSSI) in dBm, as received by the base station whose web interface you
are currently accessing. The maximum number of multicell chain levels is 24.
When the DECT system setting Auto congure DECT sync source tree is
set to "enabled", the sync source tree will be generated automatically.
When the setting is "disabled", the sync source tree must be congured
manually by selecting each base station's sync source from the drop-
down menu.
The visible option shows which sync source each of the base stations in the
DECT chain is currently using. If you select a dierent option, the chain must
be rebooted. Options:
Select as primary: This option is visible when the base station is selected
as the primary. Select from the drop-down menu of a secondary base
station to make that base station the primary.
Primar y:RPNxx (-xxdBm): This option is visible when the base station is
a secondary level base station whose sync source is the primary.
Example: Primary:RPN00 (-72dBm)
Levelx: RPNxx (-xxdBm): This option is visible when the base station is a
secondary level base station whose sync source is another secondary
level base station.
Example: Level1:RPN04 (-68dBm)
(any) R PN: Indicates a base station that is not synchronized to any other base
station.
70

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Snom M900 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Snom M900

Snom M900 Bedienungsanleitung - Deutsch - 79 seiten

Snom M900 Bedienungsanleitung - Englisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info