6.3. Hydraulic installation
Chapter 12 "Installation Schemes" contains the possible connection schemes in the
context of a central heating installation, with or without domestic water heating.
The minimum connection temperature of the circulation pump must be 60°C in order
to avoid condensation inside the recuperator.
The pump must be applied in the return circuit of the radiators, where the temperature
is lower.
The thermostat should be dipper, and like the combustion regulator, it should be
applied to the outlet pipe for the radiators.
Fit the thermostatic valve sleeve into the free 3/4" outlet. This will depend on which
side you have installed the automatic air intake regulator. You have option A if you placed
it on the right and option B if you placed it on the left. Insert the thermostatic valve
temperature probe into the thermostatic capsule and secure it.
Figure 26