Installation
6
How can I adjust the limit switches?
Gate wing closes less
Gate wing closes more
Gate wing opens more
Gate wing opens less
Preparation for Stop Position Settings
Never adjust limit switches with a power drill or similar tool, as
the switches could thereby be pulled from the holders.
Never connect drive to 230V power, as this would immediately
destroy the motor.
First install and adjust the limit switches for “gate OPEN” and
“gate CLOSE”. Ensure that the gate wing does not touch the
housing to prevent damage to the drive.
Always tighten the limit switch cables to prevent jamming within
the protective tube.
• Upon the first command, the drives must move the gate in direction
“OPEN”. If this is not the case, exchange the connecting cables of the
drive at the control unit.
• Mount hood.
• Engage drive (1) and lock it (2).
1. Pull out push rod to a length of C1 = 270 mm.
2. Measure dimensions A and B,
look up dimensions C1 and C2 in the A/B dimension table.
3. Connect drive to control unit.
- First connect and adjust drive at the wing with stop (M1),
then install drive for pedestrian wing (M2).
4. Set all DIL switches to OFF.
5. Set jumpers: single-wing or double-wing gate
6. Connect control system to power supply.
LED for power supply is on and “WL” LED flashes.
Connection of drive systems
1-wing gate 2-wing gate
(M2) pedestrian wing (M1) wing with stop (M2) pedestrian wing
Terminals 7 + 8 Terminals 5 + 6 Terminals 7 + 8