Configures the following settings.
Switch 1: Sets which settings are reset when the RESET switch is pressed.
Switch 2: Sets whether the +48 V power supply (phantom power) is turned on/off when an audio input device is
connected. The setting is applied immediately.
This function is enabled when [Audio] > [Audio Input] > [AUDIO IN Select] is set to [MIC] in the camera menu.
Note
Setting switch 2 to the ON position and connecting a microphone that is not compatible with a +48 V source may damage the
connected device. Check the setting before connecting the device.
Switch 3: Enables/disables VISCA over IP communication. The settings are applied when the camera is turned on.
Set to the ON position to use the unit when connected to a remote controller (RM-IP500).
Note
If the administrator password has not been configured, VISCA over IP communication is disabled, regardless of the switch
setting. For details about configuring the administrator password, see “Initializing the Unit.”
Switch 4: Changes the speed of pan/tilt operations sent from the infrared remote control. The setting is applied
immediately.
Setting Description
OFF
(default)
Resets the network connection settings only. The network settings, security settings, and user
information (user name and password) of the unit will be reset.
ON Resets all settings to factory defaults.
Setting Description
OFF
(default)
Do not supply +48 V power (phantom power supply). Configure this setting when using an external
audio device (such as a mixer), dynamic microphone, or microphone with a built-in battery.
ON Supply +48 V power (phantom power supply) to a phantom power compatible microphone connected to
the AUDIO IN connector (CH-1 or CH-2).
Setting Description
OFF (default) Will not respond to VISCA over IP commands.
ON Accepts VISCA over IP commands.
Setting Description
OFF (default) Operates at normal speed.
ON Operates at maximum speed.