Factory settings
All settings can be reset, returning the controller to its delivery state.
All of the controller‘s parametrization, statistics, etc. will be lost irrevocably. The controller must then be commissioned once
again.
Time & Date
Serve to set the current time and date.
For time-dependent functions such as circulation and anti-legionella and the evaluation of system data, it is essential that the
time is accurately set on the controller. Please note that the clock continues to run for about 24 hours if the mains voltage is inter-
rupted, and afterward must be reset. Improper operation or an incorrect time may result in data being cleared, recorded incor-
rectly or overwritten. The manufacturer accepts no liability for the recorded data!
Starting aid
For some solar systems, in particular for vacuum tube collectors, the measurement recording on the collector sensors may be too slow or
imprecise, because the sensor is often not on the warmest spot. With an activated starting aid, the following procedure occurs: If the tem-
perature on the collector sensor increases within a minute by the value defined under “increase”, the solar circulation pump will be turned on
for the set “purging time” so that the medium to be measured is transported to the collector sensor. If there is still no normal switching con-
dition through this, there will be a 5 minute block time for the start wizard function.
This function should only be activated by a technician if problems occur with the measurement recording. Observe in particular
the instructions from the collector manufacturer.
The menus "Purging time" and "Increase" are only displayed when the starting aid function is set to "On".
Purging time
If the temperature on the collector sensor increases within a minute by the value defined under “increase”, the solar circulation pump will be
turned on for the set “purging time” so that the medium to be measured is transported to the collector sensor. If the set ΔT is not reached, a 5-
minute circulation pause time for the starting aid function will apply.
Increase
If the temperature at the collector reaches within a minute the value defined, the solar pump is turned on for the duration of the purging time.
Global radiation sensor
With the global radiation sensor, a start-up operation can be triggered depending on the solar
radiation. If the set radiation intensity exceeded at the sensor, the start-up aid is activated and the solar pump is switched on for the set rins-
ing time. If within this time no start condition is reached, the start-up function is blocked for the set time.
Radiation sensor
The sensor input can be defined here, to which the global radiation sensor is connected.
Radiation intensity
If the radiation intensity set here is exceeded in watts See " Starting aid " on page 42per at the radiation sensor, the starting aid function
will be triggered,
Blocking time
Here a blocking time in minutes can be defined. Within this the starting aid function is disabled.
Daylight saving time
If this function is activated, the controller automatically changes to winter time or summer time (DST, Daylight Savings Time).
Eco Display Mode
In Eco Display Mode the backlight of the display is switched off if no buttons are pushed for 2 minutes.
42

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sorel LTDC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Sorel LTDC

Sorel LTDC Bedienungsanleitung - Deutsch - 50 seiten

Sorel LTDC Bedienungsanleitung - Holländisch - 36 seiten

Sorel LTDC Bedienungsanleitung - Französisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info