GB 6
2.1 TECHNICAL DATA
La Vela I La Vela II La Vela III La Vela IV La Vela V La Vela VI La Vela VII La Vela VIII La Vela IX
Brennstoffart Bioethanol
(96.6% degree of purity
Füllmenge max. 0,18 litres max. 0,18 litres max. 0,18 litres max. 0,5 litres max. 0,5 litres max. 0,5 litres max. 0,5 litres max. 0,5 litres max. 0,5 litres
Brennstoffverbrauch 0,045 l/h 0,045 l/h 0,045 l/h 0,08 l/h 0,08 l/h 0,08 l/h 0,08 l/h 0,08 l/h 0,08 l/h
Brenndauer approx. 4 h approx. 4 h approx. 4 h approx. 6 h approx. 6 h approx. 6 h approx. 6 h approx. 6 h approx. 6 h
Temperatur im Tank < 65°C < 65°C < 65°C < 65°C < 65°C < 65°C < 65°C < 65°C < 65°C
Gewicht komplett mit Brenner 1,5 kg 1,8 kg 2,0 kg 1,6 kg 1,8 kg 2,0 kg 11,0 kg 12,5 kg 14,0 kg
2.2 BASIC REQUIREMENTS FOR INSTALLATION
The ebios-fire may only be set up in rooms and locations where there are
no hazards due to the site, structural conditions and type of use. The floor
area of the installation room must be designed and dimensioned so that the
ebios-fire can be operated properly and as per the intended use.
Only permitted and sufficiently strong transport aids may be used to trans-
port the ebios-fire.
The following points must be noted to ensure safe and problem-free
transport.
• There must be no fuel in the tank during transportation.
DAMAGE DURING TRANSIT should be reported immediately to the supplier.
Protect the cladding and visible elements from soiling and damage during
installation and transportation.
All the relevant national and European standards as well as the local regula-
tions (fire protection regulations etc.) must be observed and applied during
installation and operation of the ebios-fire! The list of regulations given
below is not exhaustive.
BetrSichV Operational safety ordinance
Vbf Flammable liquids directive
BsV Fire protection directive of the relevant German federal state (Bundesland)
LBO Federal state construction directives
GefStoffV Hazardous substances directive