680703
18
Zoom out
Zoom in
Vorherige Seite
1/68
Nächste Seite
1. Safety measures
While the pump is operating persons must
not be in the liquid to be pumped.
The pump may be connected only by
means of a safety switch for fault currents, with
a rated opening current up to 30 mA and a socket
with an earth contact installed in conformity with
the regulations.
Protection: at least 10 Amps.
Operation in swimming pools and garden ponds is
admitted.
For other operation, the provisions in conformity with
the standard VDE 0100 part 702 must be respected.
CAUTION: Before checking, connect the pump and
the system with no voltage!
Replacing the line connecting up with the mains
requires using special tools and therefore may be
done only by the manufacturer or its service engineers.
The pump may operate only with a pipe connecting
the appliance (extension) that is no lighter than a
rubber hose mod. H07 RNF in conformity with the DIN
57282 or DIN 57245 standard.
(For your safety)
The voltage (230 Volts alternating current) indi-
cated on the pump’s rating plate must correspond
to the available mains voltage.
Before starting it is necessary to make sure by having a
check made by qualified personnel that there are the
necessary electrical protection measures.
N 1BD83?>>53D9?>
N 1BD854>5EDB1<
N The safety switch for fault currents corresponds to the
safety regulations of the electricity board and functions
perfectly.
N Plug connections must be protected from water. If there
is a risk of flooding, plug connections must be placed
somewhere safe.
N Definitely avoid pumping aggressive liquids and abrasive
products.
In the event of the pump failing, repair work may only be
carried out by the repair workshops of the technical
service. Only genuine spare parts must be used.
SUBMERSIBLE PUMP
It is notified that in conformity with the law on product
liability
we cannot be held responsible
for the damage caused by our appliance:
a) because of improper repairs not carried out by the
personnel of the assistance points authorized by us;
b) or if GENUINE SPARE PARTS are not used to replace
parts;
c) or if the indications and provisions given in the instruc-
tions handbook are not complied with.
The same provisions hold for the accessories.
Resistance
The maximum temperature of the delivery liquid should
never exceed +35$C in continuous operation.
Infiammable, combustible or explosive liquids cannot
be conveyed with this pump!
In particular, do not use engine fuels, detergents, or other
chemical products.
2. Use
CAUTION! Sector of use
“DRAINAGE”To transfer and empty fresh to
slightly polluted water from rainwater barrels and
casks.
“VORTEX”Portable submersible pump for
discharge and waste water with solids in suspen-
sion.
Also used as emergency pump, in case of over-
flowing with muddy water, thanks to its large
suction filter.
To achieve excellent motor cooling the pump
casing is provided with a breather hole that enables
water to flow out.
The pump must be protected from running dry.
Starting
First put the pump into water and then
connect the plug.
The pump is ready for use.
3. Before starting
Installation of your canned motor pump is:
N69H54G9D8169H4@9@5?B
N69H54G9D816<5H92<58?C5
Take care
When installing it is necessary to take care that the pump
is never fitted hanging from its delivery pipe, but is always
placed in a raised position with respect to the bottom of
17
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Speroni STF 1000 HL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info