720740
9
Zoom out
Zoom in
Vorherige Seite
1/198
Nächste Seite
9
GB
3.
Aim the laser’s vertical line at the rst corner or reference
point (Figure
F
#1).
4.
Measure half the distance across the wall (D1/2)
(Figure
F
#1).
5.
Where the horizontal laser line crosses the halfway point
(D1/2), mark point P1 (Figure
F
#1).
6.
Rotate the laser to another corner or reference point
(Figure
F
#2).
7.
Where the horizontal laser line crosses the halfway point
(D
1/2), mark point P2 (Figure
F
#2).
8.
Measure the vertical distance between P1 and P2
(Figure
F
#3).
9.
If your measurement is greater than the Allowable
Distance Between P1 & P2 for the corresponding
Distance (D1) in the following table, the laser must be
serviced at an authorized service center.
Distance (D1)
Allowable Distance
Between P1 and P2
9m (30’) 3mm (1/8”)
12m (40’) 4mm (5/32”)
15m (50’) 5mm (7/32”)
Horizontal Line Accuracy - Level
Checking the level of the laser’s horizontal line requires a at
vertical surface at least 30’ (9m) wide.
1.
Place the laser at one end of the wall as shown in Figure
E
#1, and turn the laser ON.
2.
Press once to display a horizontal line.
3.
Mark two points (P1 and P2) at least 30’ (9m) apart along
the length of the laser’s horizontal line on the wall (Figure
E
#1).
4.
Relocate the laser at the other end of the wall and align the
laser’s horizontal line with point P2 (Figure
E
#2).
5.
Mark point P3 on the laser line near point P1
(Figure
E
#2).
6.
Measure the vertical distance between points P1 and P3
(Figure
E
#2).
7.
If your measurement is greater than the Allowable
Distance Between P1 & P3 for the corresponding
Distance Between P1 & P2 in the following table, the laser
must be serviced at an authorized service center.
Distance Between
P1 & P2
Allowable Distance
Between P1 and P3
9m (30’) 6mm (1/4”)
12m (40’) 8mm (5/16”)
15m (50’) 10mm (13/32”)
Vertical Line Accuracy - Plumb
Checking the plumb of the laser’s vertical line.
1.
Measure the height of a door jamb (or a reference point on the
ceiling) to get height D1 (Figure
G
#1).
2.
Place the laser as shown in Figure I #1 and turn the laser
ON.
3.
Press twice to display a vertical line.
4.
Aim the laser’s vertical line toward the door jamb or the
reference point on the ceiling (Figure
G
#1).
5.
Mark points P1, P2, and P3, as shown in Figure
G
#1.
6.
Move the laser to the opposite side of point P3 and aim the
laser’s vertical line toward point P2 (Figure
G
#2).
7.
Align the vertical line with points P2 and P3, and mark point
P4 (Figure
G
#2).
8.
Measure the distance between P1 and P4 (Figure
G
#3).
9.
If your measurement is greater than the Allowable
Distance Between P1 & P4 for the corresponding Vertical
Distance (D1) in the following table, the laser must be
serviced at an authorized service center.
Height of Vertical
Distance (D1)
Allowable Distance
Between P1 and P4
2.5m (8’) 1.5mm (1/16")
5m (16) 3.0mm (1/8”)
6m (20’) 3.6mm (9/64”)
9m (30) 5.5mm (9/32”)
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stanley FMHT1-77438 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info