NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER SOURCE
TROUBLESHOOTING GUIDE
Problem
Possible Cause Solution
Heater fires, but Main PCB shuts
heater off after a short period of time.
Lamp is flickering, and LED display
shows “E1”
1. Incorrect pump pressure
2. Dirty Input, Output or Lint Filter
3. Dirty Fuel Filter
4. Nozzle is Dirty
5. Photocell lens is Dirty
6. Photocell not installed properly
7. Photocell Defective
8. Improper electrical connection
between Main PCB and Photocell
1. Adjust Pump Pressure
2. Clean/replace Air Filter
3. Clean/replace Fuel Filter
4. Clean/replace Nozzle
5. Clean/replace Photocell
6. Adjust Photocell position
7. Replace Photocell
8. Check wiring connections (See Wiring
Diagrams, Page 7)
Heater will not operate, or motor runs
for short time. Lamp flickers and LED
display shows “E1”
1. No paraffin in fuel tank
2. Incorrect pump pressure
3. Corroded Spark Plug or incorrect plug
gap.
4. Dirty Fuel Filter
5. Dirty Nozzle
6. Moisture in Fuel/Fuel Tank
7. Improper electrical connection
between Transformer and Circuit
Board
8. Ignitor Wire not connected to Spark
Plug
9. Defective Ignitor
1. Fill tank with fresh paraffin
2. Adjust Pump Pressure
3. Clean/replace Spark Plug
4. Clean/replace Fuel Filter
5. Clean/replace Nozzle
6. Rinse out fuel tank with clean fresh
paraffin
7. Inspect all electrical connections. See
Wiring Diagrams
8. Re-attach Ignitor wire to Spark Plug
9. Replace Ignitor
Fan does not operate when heater is
plugged in and Power Switch is in the
“ON” position. The lamp is flickering
or on and LED Display shows “E1” or
“E2”
1. Thermostat is set too low (Does not
apply to ST-45-KFA-E)
2. Broken electrical connection between
Main PCB and motor
1. Rotate thermostat to a higher setting
2. Inspect all electrical connections. See
Wiring Diagrams (Page 7)
Lamp is flickering, and LED display
shows “E3”
1. Thermostat Switch has failed 1. Replace Thermostat Switch
Poor Combustion and / or excess soot
production
1. Dirty Input, Output or Lint Filter
2. Dirty Fuel Filter
3. Poor quality of fuel
4. PSI is too high or too low
1. Clean/replace Air Filter
2. Clean/replace Fuel Filter
3. Be sure fuel is not contaminated or old
4. Use proper pressure
Heater does not turn on and the lamp
is not lit
1. Temperature limit sensor has
overheated
2. No electrical power
3. Fuse Blown
4. Improper electrical connection
between Temperature Limit Sensor
and Circuit Board
1. Push Power Switch to “OFF” and allow
heater to cool for 10 minutes. Push
Power Switch to back to “ON”
2. Check power cord and extension cord
to insure of proper connection. Test
power supply
3. Check/replace Fuse
4. Inspect all electrical connections.
Wiring Diagrams (Page 7)
80

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stanley ST-125T-KFA-E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info