The detection zone can be
optimised to suit require-
ments. Using the shrouds
provided with the lamp, you
can also adjust the sensor's
detection zone. Lens seg-
ments can be covered so as
to prevent the light from
being triggered inadvertent-
ly, for example, by cars or
passers-by.
If you want the light to co-
me on independently of a
heat source, switch on the
indoor power switch mo-
mentarily. This will activate
the light for the period
selected.
Weather as well as strong
electromagnetic fields can
affect operation of the Gar-
den Lamp. Strong gusts of
wind, snow, rain or hail may
cause switching errors be-
cause the unit cannot
distinguish sudden change
in temperature from heat
sources.
The Fresnel lens (detection
lens) can be wiped clean
with a damp cloth (not
using detergent) if it gets
dirty.
Operation
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
Declaration of conformity
Technical Specifications
Functions
10
Once the SensorLamp has
been connected, it can be
switched on. Two setting
controls are provided on the
bottom of the unit.
Attention: Pull down slide
cap and tilt up sensor head.
Use a small screwdriver
from below to set timer and
light threshold.
A) Switch-off delay (time
setting)
At the bottom of the unit
you can set the light to
come on for any period be-
tween approx. 10 sec. and
a maximum of 15 min. The
shortest period, approx. 10
sec., is selected by turning
the control fully clockwise.
The longest period, 15 min.,
is selected by turning the
control fully anticlockwise.
(The unit leaves the factory
set to the shortest time). It
is recommended to select
the shortest time for ad-
justing the detection zone
and for performing the walk
test.
B) Light level setting
(threshold)
The desired light threshold
can also be adjusted contin-
uously from about 2 lux to
2,000 lux on the bottom of
the unit. Turn control fully
clockwise to select daylight
operation at about 2,000
lux. Turned fully anticlock-
wise, control is set to dusk-
to-dawn operation at about
2 lux (on leaving factory,
light is set to daytime
operation).
The control must be turned
fully clockwise when ad-
justing the detection zone
and performing the walk
test in daylight.
Three switch setting capa-
bilities are provided on the
unit above the sensor.
Slide switch to left; switch
position (I): Lamp is switch-
ed on all the time.
Switch position (0)
Lamp is switched off.
Slide switch to right; switch
position (Auto): Lamp con-
trolled in sensor mode.
Mains power supply: 220–240 V mains connection
Sensor angle of coverage: 180° horizontal, 8° vertical
Sensor swivel range: 55° horizontal, 35° vertical
"ON" time, adjustable: 10 sec. – 15 min.
Reach: 12 m in front, 10 m at sides
Detection area: approx. 240 m
2
Light bulb output: 100 watt max.
Enclosure: IP 44
Tip!
at
least
5 min.