593164
11
Zoom out
Zoom in
Vorherige Seite
1/75
Nächste Seite
- 20 - - 21 -
How it works / Basic function
The high-frequency presence
detectors from the Control PRO
range control lighting as well as
heating, ventilation and air-con-
ditioning (COM 2 only), e.g. in of-
fices, WCs, public buildings or at
home, in relation to ambient
light level and the presence of
persons. Modern, high-frequen-
cy technology guarantees that
movement is detected absolute-
ly anywhere irrespective of radi-
ated temperature. Sensing
movement in two directions, the
DUAL HF sensor is ideal for corri-
dors in hotels, schools and office
buildings. The presence detec-
tor's switching outputs and
reach are set at the potentio-
meters and dip switches or by
means of the optional remote
control. Presence Control has
a low intrinsic power consump-
tion.
Presence Control PRO
HF 360 COM 1 / COM 1 AP
DUAL HF COM 1 / COM 1 AP
1 switching output operating
in relation to brightness setting
and presence of persons.
Settings:
- Brightness setting
- Stay-'ON' time, pulse mode,
IQ mode
Presence Control PRO
HF 360 COM 2
1 switching output, such as
COM 1. Plus a 2nd switching
output for HVAC (heating /
ventilation / air conditioning)
governed by presence.
Settings:
- Stay-'ON' time
- Switch-'ON' delay
- Room surveillance
Presence Control PRO
HF 360 DIM
DUAL HF DIM
1 switching output operating
in relation to brightness setting
and presence of persons.
Settings:
- Brightness setting
- Stay-'ON' time, IQ mode
- Orientation light
- Constant lighting control
Detection zone
The reach of the HF 360 is electronically adjustable.
1 or 2 detection directions can be masked out for
adjustment to the room situation. An angle of cov-
erage of 360° provides a max. reach of 8 m.
The DUAL HF sensor has 2 special HF sensors that
detect movement from the ceiling in both direc-
tions. Controlled electronically, reach is infinitely
variable in both directions from 3 x 3 m – 10 x 3 m.
HF 360 mounting height 2.8 m DUAL HF mounting height 2.8 m
Disconnect the power supply
before attempting any work
on the sensor!
During installation, the elec-
tric power cable to be con-
nected must be dead. There-
fore, switch 'OFF' the power
first and use a voltage tester
to make sure the wiring is off
circuit.
Installing the sensor involves
work on the mains power
supply. This work must there-
fore be carried out profes-
sionally in accordance with
the applicable national wir-
ing regulations and electrical
operating conditions (VDE
0100).
It is only permissible to use
electronic ballasts with isola-
ted control signal at the DIM
1-10 V control output.
System components
Load module
Sensor module
Sensor base
Dip switches
(1) Normal/test mode
(2) Semi-/fully automatic
mode
(3) Button/switch
(4) 'ON' / 'ON'-'OFF' button
(5) DIM option
Constant lighting control
'ON'/'OFF'
Twilight setting
Time setting
Switching output 1
HVAC stay-'ON' time
Switching output 2
HVAC switch-'ON' delay
Switching output 2
Reach setting
Clamping-type ceiling
adapter, optional
Surface-mounting adapter
IP 54, optional
Locking mechanism
Assembly/Installation
Parallel-connected
configurations
Stay-'ON' time
Orientation light
DIM option
Film shroud for minimising
the detection zone (HF 360).
Assembly/Installation (see chart on page 2)
The sensor is only intended for
concealed, indoor installation in
ceilings (apart from the COM 1
AP - surface-mounted - option).
A clamping-type ceiling adapter
or surface-mounting adapter is
not included.
Sensor and load module come
ready assembled and must be
plugged together after fitting
the load module and setting the
potentiometers/dip switches.
Accessories:
Clamping-type ceiling adapter,
EAN no.: 4007841 000370
Surface-mounting adapter,
EAN no.: 4007841 000363
Guard cage,
EAN no.: 4007841 003036
Service remote control,
EAN no.: 4007841 000387
User remote control,
EAN no.: 4007841 003012
Operating instructions
GB
Dear Customer,
Congratulation on purchasing
your new STEINEL presence de-
tector and thank you for the
confidence you have shown in
us. You have chosen a high-qual-
ity product that has been manu-
factured, tested and packed with
the greatest care.
Please familiarise yourself with
these instructions before at-
tempting to install the presence
detector because prolonged, re-
liable and trouble-free operation
will only be ensured if it is fitted
and used properly.
We hope your new STEINEL
sensor will bring you lasting
pleasure.
Safety warnings
GB
PC PRO HF360_DualHF_Zentraleuropa.indd 20-21PC PRO HF360_DualHF_Zentraleuropa.indd 20-21 11.09.13 10:3811.09.13 10:38
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel HF 360 DIM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info