Functions
Adjusting screw left stop
position means: minimum
reach (approx. 1 m / factory
setting).
Adjusting screw right stop
positon means: maximum
reach (approx. 8 m).
(only for HF 360 AP)
Reach setting
(Sensitivity)
ii
ii
i
The term reach denotes the
approximately circular
diameter that results as the
detection zone.
1 - 8 m
Functions
2
LUX
Twilight setting
(Response threshold)
gg
gg
g
The desired sensor re-
sponse threshold can be
adjusted continuously from
approx. 2 lux to 2000 lux.
Adjusting screw right stop
position means: daylight
operation approx. 2000 lux
(factory setting).
2 - 2000 lux
Adjusting screw left stop
position means: night-time
operation approx. 2 lux.
When adjusting the detec-
tion zone and for the per-
formance test in daylight, the
adjusting screw must be set
to the RH stop position.
Time setting
(Switch/off delay)
hh
hh
h
The desired duration of illu-
mination of the connected
light can be continuously
adjusted from approx.
10 sec. to max. 30 min.
Adjusting screw left stop pos-
ition means: shortest time
approx. 10 sec. (factory set-
ting)
Adjusting screw right stop
position means: longest
time approx. 30 min.
The timer is restarted by
any motion detected before
this time elapses.
30
10 sec. - 30 min.
The shortest time setting is
recommended when adjus-
ting the detection zone and
performing a functional test.
Note: After every off switch-
ing, further motion detection
is interrupted for approx.
2 seconds. Only after this
time elapses is it possible
for the Sensor Switch to
switch light again.
16
Installation
Note for IR 180 AP:
The installation position
should be at least 1 m from
a light, since heat radiation
may trigger the system.
Installation procedure:
1. Loosen housing screws
and open housing a,
then loosen sensor unit
c (screw) and remove
with the basic element
b.
2. Hold base of housing on
wall (with the inscription
TOP facing upwards)
and mark the drilling
holes.
3. Drill holes with a 6 mm
bit.
4. Insert dowels in the
holes.
5. Screw the base of the
housing in place with the
enclosed screws.
6. Strip the cable (approx.
70 mm) and remove
approx. 5 mm of insula-
tion from the flexible
ends.
7. Push through sealing
plugs and pass the ca-
ble through (the cable
sheath must be comple-
tely surrounded by the
sealing plug).
Connecting the supply
lead to the basic element
(refert to ill. on page 4):
The mains lead consists of
a 3 phase cable.
L = phase conductor (usu-
ally black or brown)
N = neutral conductor
(usually blue)
L = phase conductor (usu-
ally black or brown)
If in doubt, the cable must
be identified with a voltage
tester. Switch off the cur-
rent again. Phases (L) and
(L‘) in addition to the neu-
tral conductor (N) are con-
nected to the terminal
block. A protective-earth
conductor is not required.
Important: Reversing the
connections may result in
damage to the unit.
8. Insert basic element b
into the housing section
a (terminal connection
at bottom).
9. Carefully push on the
sensor module c (tak-
ing care not to jam) and
screw to the housing
base section.
10.After the mains connec-
tion has been made, the
sensor switch can be
operated (refer to func-
tions section).
11. Finally apply the design
shade d and screw in
place.
Note:
Parallel switching of
IR 180 AP and HF 360 AP
is possible. Nevertheless, a
neutral lead must be pres-
ent on each flush box. The
max. output to be switched
does not increase as a re-
sult.
2
lux
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel IR 180 AP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info