■ Disconnect the power
supply before any work
on the motion detector!
■ During installation, the
electric power cable to
be connected must be
voltage-free. There-
fore, switch off the power
first and check freedom
from voltage with a
voltage tester.
■ Installation of the sensor
involves work on the
mains power supply; this
work must therefore be
carried out professionally
in accordance with regu-
lations.
■ Please note that the
sensor must be protected
by a 10 A circuit breaker.
The mains supply lead
must be no greater than
10 mm in diameter.
■ Perform time and twilight
adjustment only with the
lens installed.
Safety notification
Principle
Important: The most reli-
able motion detection is
achieved by mounting the
unit diagonally to the direc-
tion of movement and en-
suring that no obstacles
(such as trees or walls)
obstruct the line of sight.
Max. reach 12 m Max. reach 5 m
Walking direction: frontal Walking direction: diagonal
The detector is equipped
with two 120° pyro sensors
which detect the invisible
infrared heat emitted by
moving objects (pedes-
trians, animals, etc.). The
heat thus detected is elec-
tronically converted and
switches on connected
consumers (e.g. a light).
No heat radiation is detect-
ed through obstacles, such
as walls or glass and no
switching therefore occurs.
With the aid of the two pyro
sensors, a detection angle
of 180° (with an opening
angle of 90°) is achieved.
The lens is removable and
can be rotated. This allows
two basic reach settings of
max. 5 m or 12 m. The
infrared sensor can be
installed without difficulty
on inside and outside cor-
ners using the enclosed
wall mounts.
Dimensions: (H x W x D) 120 x 76 x 56 mm
Output: max. 1000 W (ohmic load, e.g. filament bulb)
max. 1500 W (uncorrected, inductive, cos ϕ = 0.5,
e.g. fluorescent lamps)
max. 1600 W (electronic ballasts, capacitive;
e.g. energy-saving lights, max. 8)
Connection: 230–240 V, 50 Hz
Angle of coverage: 180° horizontal, 90° vertical
Sensor reach: basic setting 1: max. 5 m
basic setting 2: max. 12 m
+ fine adjustment with shrouds: 1–12 m
Time setting: 10 sec.–15 min.
Twilight setting: 2–2000 lux
Enclosure: IP 54
Installation instructions
Appliance description
Dear customer,
Thank you for the confi-
dence that you have placed
in us in purchasing your
new STEINEL infrared sen-
sor. You have decided on a
high quality product, manu-
factured, tested and pack-
ed with the greatest care.
Please familiarise yourself
with these instructions
before installation, since
only correct and commis-
sioning guarantees long,
reliable and trouble-free
operation.
We hope you enjoy your
new usage appliance.
Safety screw
Decorative cover
Lens (removable and
rotatable to select the
reach – basic setting of
max. 5 m or 12 m
Twilight setting
2–2000 lux
Time setting
10 sec.–15 min.
Catch (housing can be
swung open for installa-
tion and power supply
connection)
Technical specifications
GB
12 13