592628
5
Zoom out
Zoom in
Vorherige Seite
1/54
Nächste Seite
98
Installation Instructions
Dear Customer,
Congratulations on purchasing your new STEINEL
designer sensor-switched outdoor light and thank you
for the confidence you have shown in us. You have
chosen a high-quality product that has been manu-
factured, tested and packed with the greatest care.
Please familiarise yourself with these instructions
before attempting to install the SensorLight because
prolonged reliable and trouble-free operation will only
be ensured if it is fitted and started properly.
We hope your new SensorLight will bring you lasting
pleasure.
GB
Principle
The SensorLight is an active motion detector. The
integrated HF-sensor emits high-frequency electro-
magnetic waves (5.8 GHz) and receives their echo.
Any movement by persons in the light's detection
zone is noticed by the sensor as a change in echo.
A microprocessor then triggers the 'switch light ON'
command. Detection is possible through doors,
panes of glass or thin walls.
Detection zones for wall mounting:
1) Minimum reach (2 m)
2) Maximum reach (5 m)
1m
2m
5m
10m
Safety warnings
n Disconnect the power supply before attempting any
work on the unit.
n During installation, the electric power cable to be
connected must not be live. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off circuit.
n Installing the SensorLight involves work on the
mains voltage supply. This work must therefore be
carried out professionally in accordance with
national wiring regulations and electrical operating
conditions.
( -VDE 0100, -ÖVE / ÖNORM E8001-1,
- SEV 1000)
D A
CH
Note:
The high-frequency output of the iHF-sensor is
approx.1 mW – that's 1000 times less than the trans-
mission power of a mobile phone or the output of a
microwave oven.
approx. 1 mW
approx. 1000 mW
System Components
Light enclosure
Wall mount
Bottom shade panel
Top shade panel
Mains lead, concealed wiring
Mains lead, surface wiring
Mounting hook to simplify installation /
cable grips
Sealing plug
Spacers for surface wiring
House number panel (L 820 LED iHF)
Retaining screws for house number panel
(L 820 LED iHF)
Reach setting
Time setting
Twilight setting
Programme setting
Manual override function
Note:
The sensor is suitable for switching light ON automati-
cally. Weather conditions may affect the way the sen-
sor works. Strong gusts of wind, snow, rain or
hail may cause the light to come ON when it is not
wanted.
Installation
To obtain the specified reach of 5 m, the sensor
should be installed at a height of approx. 2 m.
Connecting the mains supply lead (see illustration)
The mains supply lead is a 3-core cable.
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; then disconnect from the power sup-
ply again. Phase (L) and neutral conductor (N) are
connected to the terminal block.
Important: Getting the cable connections crossed
will produce a short circuit in the unit or in your fuse
box. In this case, you must identify the individual con-
ductors once again and re-connect them.
A mains switch for switching the light ON and OFF
can of course be fitted in the mains lead.
Note: For connection, light enclosure must be
pushed onto mounting hook so as not to exert
tension on the internal conductors.
Time setting (switch-off delay)
Factory setting: 5 sec.
The light's ON time can be set to any
period from approx. 5 sec. and a
maximum of 15 min.
Adjustment control set to:
+ = maximum time (15 min.).
= minimum time (5 sec.).
It is recommended to select the shortest time for
setting the detection zone.
Any movement detected before this time elapses will
re-start the timer. The shortest time setting is recom-
mended when adjusting the detection zone and per-
forming a functional test.
Note: After the light switches OFF, it takes approx.
1 sec. before it is able to start detecting movement
again. The light will only switch ON in response to
movement once this period has elapsed.
Twilight setting (response threshold)
Factory setting: 2000 lux
The chosen response
threshold can be
infinitely varied from
approx. 2 – 2000 lux.
Adjustment control set to:
= daylight operation approx. 2000 lux.
= night-time operation approx. 2 lux.
To adjust the detection zone in daylight, the control
dial must be set to .
Programme setting
0 = Soft start / no basic lighting level ON as from
the selected twilight level
10 = soft start + basic lighting level 10 minutes
30 = soft start + basic lighting level 30 minutes
= soft start + basic lighting level all night long
5 sec. - 15 min.
2 – 2000 lux
The SensorLight can be put into operation as soon as
it has been connected to the mains power supply and
enclosure has been fitted. When the light is turned
ON manually at the light switch, it switches OFF after
10 secs. for the calibration phase and is then activat-
ed for operation in the sensor mode. It is not neces-
sary to actuate the light switch a second time.
Reach setting (sensitivity)
Factory setting: 5 m.
Reach can be infinitely varied from
1 m to 5 m.
Adjustment control set to:
+ = maximum reach 5 m
= minimum reach 1 m
It is recommended to select the shortest time for
setting the detection zone.
Reach is the term used to describe the diameter of
the detection zone produced on the ground when
mounting the SensorLight at a height of 2 m.
Functions
1 m – 5 m
1) 2)
GB
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel L 820 LED iHF wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info