The SensorLight can be put into operation as soon as
the enclosure has been fitted and the SensorLight
has been connected to the mains power supply.
Putting the light into operation manually at the light
switch turns it OFF after 10 secs. for the calibration
phase. Once calibrated, it is activated for the sensor
mode. It is not necessary to operate the light switch
a second time.
Reach setting (sensitivity)
Reach is the term used to describe the
diameter of the more or less circular
detection zone produced on the
ground after mounting the sensor
light at a height of 2.5 m. Turn the
reach control fully anticlockwise to
select minimum reach (approx. 1 m
dia.)*, and fully clockwise to select maximum reach
(approx. 8 m dia.)*. (The light leaves the factory set to
maximum reach.)
Time setting (switch-off delay)
The light can be set to stay ON for
any period of time between approx.
1 min. (control turned fully anti-
clockwise) and a maximum of 15 min.
(control turned fully clockwise).
(The light leaves the factory set to the
shortest time.) Any movement detect-
ed before this time elapses will re-start the timer. It is
recommended to select the shortest time for adjusting
the detection zone and for performing the walk test.
Note: After the light switches OFF, it takes approx.
1 sec. before it is able to start detecting movement
again. The light will only switch ON in response to
movement once this period has elapsed.
Twilight setting (response threshold)
The chosen light response threshold
can be infinitely varied from approx.
2 – 2000 lux. Turn control fully
anticlockwise to select dusk-to-dawn
operation at about 2 lux. Turn control
fully clockwise to select daylight
operation at about 2000 lux. (The
light leaves the factory set to daylight operation.) The
control must be turned fully clockwise when adjusting
the detection zone and performing the walk test in
daylight.
Functions
- 11 -
1 m – 8 m dia.*
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is perfect condition and proper working
order. The warranty period is 36 months, starting on
the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replace-
ment at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects is
excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed complete
with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the
appropriate Service Centre.
Repair Service:
Our Customer Service Department
will repair faults not covered by
warranty or after the warranty period.
Please send the product well packed
to your nearest Service Centre.
Declaration of conformity
This product complies with Low Voltage Directive
2006/95/EC, EMC Directive 2004/108/EC,
RoHS Directive 2002/95/EC and RTTE Directive
1999/05/EC.
1 min. – 15 min.
2 – 2000 lux
Installation
Important: Make sure the installation site is not sub-
ject to vibration.
Connecting a dimmer will result in damage to the
SensorLight.
Please note that the light must be protected by a 10 A
circuit breaker.
1. Hold enclosure against the wall/ceiling and
mark drill holes, paying attention to any existing
wiring in the wall/ceiling.
2. Drill the holes, insert wall plugs (6 mm dia.).
3. Fit and pierce sealing plug for mains supply lead.
4. Pass mains power supply lead though and fit the
heat-resistant wire insulator provided.
5. Screw enclosure into place.
6. Connecting the mains power supply lead (see fig.).
The mains power supply lead is a 3-core cable:
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; switch OFF the current again.
Connect the phase conductor (L) and neutral
conductor (N) to the terminal block. Insulate any PE
protective earth conductor with adhesive tape.
Technical specifications
Wattage: 1 x 13 watts (TC-DEL G24-Q1) *
plus max. of 100 W (e.g. bathroom/WC extractor fan)
5 x RS 50 max.
Connection: 230 – 240 V, 50 Hz
Installation site: indoors, wall/ceiling mounting
HF-system: 5.8 GHz CW radar, ISM band
Transmission power: approx. 1 mW
Detection: 360°, 160° opening angle, if necessary through glass, wood and stud walls
Reach: 1 – 8 m all round, infinitely variable
Time setting: 1 min. to 15 min.
Twilight setting: 2 – 2000 lux
Enclosure: IP 44
Protection class: II
Power consumption: approx. 0.9 W
Temperature range: -10°C to + 50°C
*
must only be operated with the bulb specified; bulb life is not affected by the light switching ON and OFF.
- 10 -
Important: Reversing the connections will result in a
short-circuit in the light unit or in your fuse box later
on. In this case, you must identify the individual con-
ductors once again and re-connect them. A mains
switch for switching the unit ON and OFF may of
course be installed in the mains power supply lead.
7. Set functions , , .
8. Fit shade and secure in place by rotating.
Surface wiring:
Surface wiring can be carried out as shown in the
diagrams on page 2.
Connection of an additional load
An additional load (e.g. bathroom/WC fan extractor)
may be connected to the SensorLight and will then
be switched ON and OFF by the SensorLight's elec-
tronics. Screw the load's live conductor to the termi-
nal marked L’. First remove the protective cap with a
pair of pliers. The cables must also be fitted with the
heat-resistant wire insulator. Loop neutral conductor
(N) as well as any protective earth conductor (PE)
through from the distribution box (see wiring diagram
on page 3).
Tip!
at
least
5 min.
GB
BDAL_RS 50_24spr.qxd 01.12.2010 14:44 Uhr Seite 11
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel RS 50 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info