592500
5
Zoom out
Zoom in
Vorherige Seite
1/10
Nächste Seite
The SensorLight can be put into operation as soon as
the enclosure has been fitted and the SensorLight
has been connected to the mains power supply.
Putting the light into operation manually at the light
switch turns it OFF after 10 secs. for the calibration
phase. Once calibrated, it is activated for the sensor
mode. It is not necessary to operate the light switch a
second time.
Reach setting (sensitivity)
Reach can be infinitely varied from
3 m to 8 m.
Adjustment control set to:
= minimum reach (3 m)
+ = maximum reach (8 m)
Factory setting: 8 m.
Reach is the term used to describe the diameter of
the more or less circular detection zone produced on
the ground after mounting the SensorLight at a height
of 2.5 m.
Time setting (switch-off delay)
Light ON duration can be infinitely
varied from 5 sec. to 15 min.
Adjustment control set to:
= shortest 'ON' time (5 sec.)
+ = longest 'ON' time (15 min.)
Factory setting: 5 sec.
Any movement detected before this time elapses will
re-start the timer. The shortest time setting is recom-
mended when adjusting the detection zone and per-
forming a functional test.
Note: After the light switches
'OFF', it takes approx.
1 sec. before it is able to start detecting movement
again. The light will only switch
'ON' in response to
movement once this period has elapsed.
Twilight setting (response threshold)
The response threshold can be
infinitely varied from 2 – 2000 lux.
Adjustment control set to:
= Night-time operation (2 lux)
= daylight operation (2000 lux)
Factory setting: 2000 lux
When adjusting the detection zone and performing
the walk test in daylight, the control must be set
to .
Functions
- 9 -
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is perfect condition and proper working
order. The warranty period is 36 months, starting on
the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replace-
ment at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects is
excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed complete
with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the
appropriate Service Centre.
Repair Service:
Our Customer Service Department will
repair faults not covered by warranty
or after the warranty period. Please
send the product well packed to your
nearest Service Centre.
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2002/95/EC
- R&TTE Directive 1999/05/EC
Installation
Important: Make sure the installation site is
not sub-
ject to
vibration.
Connecting a dimmer will result in damage to the
SensorLight.
Please note that the light must be protected by a 10 A
circuit breaker.
1. Hold enclosure against the wall/ceiling and
mark drill holes, paying attention to any existing
wiring in the wall/ceiling.
2. Drill the holes, insert wall plugs (6 mm dia.).
3. Pierce sealing plug for power supply lead.
4. Pass power supply leads through.
5. Screw enclosure into place.
6. Connecting the mains power supply lead (see fig.).
The mains power supply lead is a 3-core cable:
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; switch
'OFF' the current again.
Connect the phase conductor (L) and neutral con-
ductor (N) to the terminal block. Insulate any PE pro-
tective earth conductor with adhesive tape.
Technical specifications
Dimensions (HxWxD): 300 x 300 x 110 mm
Material: Aluminium (heat sink),
polycarbonate (base/diffuser)
Mains voltage: 230 – 240 V, 50 Hz
Output: 16 W LED / 460 lm
Colour temperature: 3200 kelvin (warm white)
LED life expectancy: 50.000 hours
HF-system: 5.8 GHz
Angle of coverage: 360° with 160° aperture angle also through glass, wood and stud walls
Detection reach: 3 m – 8 m all round
Twilight setting: 2 – 2000 lux
Time setting: 5 sec. to 15 min.
IP rating: IP 20
Protection class: II
Power consumption: approx. 0.9 W
Temperature range: -10° C to +50° C
- 8 -
7. Set functions , , .
8. Fit glass shade and turn clockwise to secure it in
place.
Surface wiring:
Surface wiring can be carried out as shown in
diagram I on page 2.
GB
Ø 3 m – 8 m dia.
5 sec. - 15 min.
+
+
2 – 2000 lux
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel RS LED D2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Steinel RS LED D2

Steinel RS LED D2 Bedienungsanleitung - Alle Sprachen - 54 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info