Technical specifications
RS PRO 5500 sensor/slave
Dimensions (H x W x D):
1295 x 161 x 64 mm
Mains power connection: 230 – 240 V/50 Hz
Output:
2 x 28 Watt / T5 *
1)
Additional switching capacity: - 1000 W max. (resistive load, e.g. filament bulb)
- 400 W max. (uncorrected, inductive,
cos φ = 0.5, e.g. fluorescent lamps)
- 400 W max. (electronic ballasts, capacitive,
e.g. low-energy lamps, max. of 4 x 28 W, C ≤ 132 F)
HF-system: 5.8 GHz (responds to the tiniest movement regardless of temperature) *
2)
Angle of coverage: 360°, 160° angle of aperture *
2)
(if applicable, through glass, wood or stud walls)
Transmission power: approx. 1 mW *
2)
Reach: infinitely variable from 1 – 8 m dia. (in 4 directions) *
2)
Max. area covered approx. 50 m
2
*
2)
Time setting: 1 min. – 20 mins. *
2)
Twilight setting: 2 – 2000 lux *
2)
Enclosure: IP 41 / IP 44 (when ceiling mounted)
Protection class: I
Power consumption: 0.9 W
*
1)
Lamp life is not affected by being switched "ON" and "OFF".
*
2)
For sensor-control version only
Installation
Connecting the mains power supply lead (see Fig.).
The mains lead consists of a 3-phase cable.
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using a
voltage tester; then switch "OFF" the power again.
Important: Reversing the connections will result in a
short-circuit in the light unit or in your fuse box later
on. In this case, you must identify the individual con-
ductors once again and re-connect them.
A mains switch for switching the unit "ON" and "OFF"
may of course be installed in the mains power supply
lead.
Important: Make sure the installation site is
not
subject to
vibration.
Connecting a dimmer will result in damage to the
SensorLight.
Please note that the light must be protected by a 10 A
circuit breaker.
L’ Connection of an additional load:
An additional load with max. 800 W can be con-
nected to the SensorLight, switched by the electronics.
Screw the live conductor to the load into the terminal
marked L’ on the SensorLight. Clamp the neutral
conductor in the terminal marked N together with the
neutral conductor of the mains power supply lead.
Attach the protective-earth conductor to the earth
terminal.
The SensorLight can be put into service after mount-
ing the light and connecting it to the mains power
supply. When putting the light into operation manually
at the light switch, it will switch "OFF" after 10 sec. for
the calibration phase and is then activated for sensor
mode. It is not necessary to operate the light switch
a second time.
Reach setting (sensitivity)
Reach is the term used to describe
the diameter of the more or less
circular detection zone produced
on the ground after mounting the
SensorLight at a height of 2.5 m.
Turn the reach control fully anti-
clockwise to select minimum reach
(approx. 1 m dia.), and fully clockwise to select max-
imum reach (approx. 8 m dia.). (The light leaves the
factory set to maximum reach.)
Functions
1 m–8 m dia.
Time setting (switch-off delay)
The light can be set to stay "ON" for
any period of time between approx.
1 min. (control turned fully anticlock-
wise) and a maximum of 20 mins.
(control turned fully clockwise). (The
luminaire leaves the factory set to
the shortest time.) Any movement
detected before this time elapses will re-start the
timer. It is recommended to select the shortest time
for adjusting the detection zone and for performing
the walk test.
Note: After the light switches "OFF", it takes approx.
1 second before it is able to start detecting movement
again. The light will only switch "ON" in response to
movement once this period has elapsed.
Twilight setting (sensor response threshold)
You can set the light to come "ON"
at any light level from approx.
2 – 2000 lux. Turned fully anti-
clockwise, the control is set to dusk-
to-dawn operation at approx. 2 lux.
Turned fully clockwise, the control is
set to daylight operation at approx.
2000 lux. (The light leaves the factory set to daylight
operation.) The control must be turned fully clockwise
when adjusting the detection zone and performing
the walk test in daylight.
Note: Apart from in the daylight setting, the luminaire
switches "OFF" once an hour for 1 second at all other
twilight settings to measure the current twilight.
Hint: The easiest way of finding the desired light
threshold is to start by waiting for the surrounding
brightness at which the light function is to be acti-
vated. Set the control dial to the fully anti-clockwise
position and allow the light to switch "OFF". Now
turn the control clockwise and let go as soon as the
luminaire has switched the light "ON". From now on,
the luminaire will always switch "ON" and "OFF" under
these light conditions.
1 min. – 20 min.
Recommendation:
To ensure trouble-free HF-sensor operation, we
recommend seasoning the tubes by leaving them
switched
"ON" for 100 hours. This seasoning
process can increase tube life.
1. Connect light and switch "ON"
2. Turn all 3 setting controls fully clockwise, then turn
the middle setting control fully anticlockwise and fully
clockwise again (within 10 sec.)
3.
The seasoning process is confirmed by switching the
light "OFF" twice and then back "ON" again.
4. Now turn all controls to the chosen settings.
5. The light is now left "ON" for 100 hours without
sensor function. Do not disconnect the light from the
mains power supply during this period.
6. The luminaire automatically returns to sensor mode
after 100 hours.
Note:
If tubes are not seasoned or ambient temperatures are
low, the sensor may not switch the light "OFF". In this
case, switch the light "OFF" and, for the time being,
drastically reduce the reach setting.
Please only use high-quality branded lamps.
Otherwise, we cannot guarantee that the high-
precision sensor will operate reliably.
Tip:
Using the remote control, functions can be comfort-
ably set on the floor.
2 - 2000 lux
Accessories
Remote control for RS PRO EAN No.: 400784173781
(optional, not included in delivery).
Declaration of Conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- R&TTE Directive 1999/05/EC
- WEEE Directive 2012/19/EC
GB
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel RS PRO 5500 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info