1� About This Document
Please read carefully and keep in a safe place�
Under copyright. Reproduction either in whole or
in part only with our consent.
Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
...
Reference to other information in the
document�
2� General Safety Notification
• Disconnect the power supply before attempting
any work on the unit.
• During installation, the electric power cable to be
connected must not be live. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing the sensor-switched light involves work
on the mains supply voltage.
This work must therefore be carried out pro-
fessionally in accordance with national wiring
regulations and electrical operating conditions.
(
D
- VDE 0100,
A
- ÖVE / ÖNORM E8001-1,
h
- SEV 1000)
• Only use genuine replacement parts.
• Repairs may only be made by specialist work-
shops.
3� RS PRO LED Q1
The sensor-switched indoor light is an efficient light
that controls itself. A high-frequency sensor for
detecting persons, a light sensor for identifying the
room's lighting situation as well as LEDs requiring no
maintenance provide efficient, instantaneous light.
Several lights in one room can be networked into a
group via the 868MHz wireless communication unit
(channel selection). Wireless communication to the
next light functions reliably over a distance of 50 m.
All lights then operate with equal rights and act as
one overall light.
Optionally, all function settings can be made via the
RC10 remote control ( "8� Accessories")
!
The sensor-switched light is an active motion
detector. The integrated HF sensor emits high-
frequency electromagnetic waves (5.8GHz) and
receives their echo. The change in echo caused by
the slightest movement within the detection zone of
the light is detected by the sensor. A microproces-
sor then issues the switch command "switch light
ON". Detection is possible through doors, panes of
glass or thin walls.
Detection zones:
1) Minimum reach (Ø 1 m)
2) Maximum reach (Ø 8 m)
Note:
The high-frequency power of the HF sensor is
approximately 1mW – 1000 times less than the
transmission power of a mobile phone or micro-
wave oven.
Package contents (Fig� 3�1)
Product dimensions (Fig� 3�2)
Device overview (Fig� 3�3)
A Ceiling mount
B DIP switches
Channel selection
Dimming function
C Twilight setting
D Time setting
E Reach setting
F Plug connection
G Light enclosure
H Retaining screws
4� Installation
• Switch OFF power supply (Fig� 4�1)
Connect the mains power supply lead (Fig� 4�2)
The mains power supply lead is a 3-core cable:
L = phase conductor
(usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; then disconnect from the power
supply again. Connect phase (L) and neutral con-
ductor (N) to the terminal block.
Important:
Incorrectly wired connections will produce a short
circuit later on in the product or your fuse box. In
this case, you must identify the individual conduc-
tors once again and re-connect them. A mains
power switch for turning the unit ON and OFF may
of course be installed in the mains supply lead.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged
Mounting procedure
• Select appropriate mounting location, taking the
reach and motion detection into consideration
• Switch OFF power supply (Fig� 4�1)
• Mark drill holes (Fig� 5�2)
Drill holes and insert screw anchors (Fig� 5�3)
Directly via the connection socket (Fig� 5�3)
With spacers for surface-mounted cables
(Fig� 5�4)
• Connect conductors (Fig� 4�2)
• Switch ON power supply (Fig� 5�5)
• Make potentiometer settings (Fig. 5�6)
"6. Functions"
• Set DIP switches (Fig� 5�7)
"6� Functions"
• Fit light enclosure (G) onto ceiling mount (A) and
clip into place. Pay attention to plug connection
(F) (Fig� 5�8).
• Screw in retaining screws (H)
approx� 1mW approx� 1000mW
6� Function
After the ceiling mount has been installed and the
mains connection has been made, the sen-
sor-switched light is ready for use. When putting
the light into operation manually at the light switch,
it will switch OFF after 10seconds for the calibra-
tion phase and is then activated for sensor mode.
It is not necessary to operate the light switch a
second time.
Potentiometer function (Fig� 5�6)
Reach setting (sensitivity) (E)
Factory setting: 8m
Reach is the term used to describe the diameter of
the more or less circular detection zone produced
on the ground after mounting the sensor-switched
light at a height of 2.5m.
Potentiometer set to maximum = max. reach
(approx. Ø 8 m)
Potentiometer set to minimum = min. reach
(approx. Ø1m)
Potentiometersetto"•"= sensor OFF
Motion detection and all other sensor functions are
completely deactivated. In this setting, the light can
be used as a normal light and turned ON and OFF
at the light switch (DIP 1-5 = OFF).
Limiting reach
By fitting the shrouds supplied with the light, the
reaches can be reduced in four directions
(Fig� 6�1 to 6�4).
Time setting (stay-ON time) (D)
Factory setting: 5 seconds
The light's ON time can be set to any period from
approx. 5seconds to a maximum of 15minutes.
Any movement detected before this time elapses
will restart the timer.
Note: After the light switches OFF, motion detection
is interrupted for approximately 1second. The light
will only switch ON in response to movement once
this period has elapsed.
Twilight setting (response threshold) (C)
Factory setting: 2000 lux
The light's chosen response threshold can be infinite-
ly varied from approximately 2 to 2000 lux.
Control dial set to = daylight operating mode
(depending on ambient light level)
Control dial set to = night-time operation
(approx. 2lux)
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel RS PRO LED Q1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info