593287
6
Zoom out
Zoom in
Vorherige Seite
1/54
Nächste Seite
- 10 - - 11 -
Technical SpecificationsFunction Setting by DIP Switches
ON = operation of a group
OFF = if individual light operation is required
00 = no dimming level, light ON in response to move-
ment as from the twilight setting for the time
selected
11 = dimmed all night long. Light ON in response to
movement. Light OFF as from twilight setting
selected
10 = Light ON in response to movement from
twilight setting / + basic brightness (10%) for
10 min. after time set elapses
01 = Light ON in response to movement from
twilight setting / + basic brightness (10%) for
30 min. after time set elapses
Basic brightness 10 %
Basic brightness provides illumination at approx.
10 % of full light output. The light only switches to
maximum output of 100 % (for the time selected,
see Switch-off delay ) in response to movement
in the detection zone. The light then switches to the
level of basic brightness selected.
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is in perfect condition and proper work-
ing order. The warranty period is 36 months and
starts on the date of sale to the consumer. We under-
take to remedy faults caused by material or manufac-
turing defects. This warranty undertaking shall be
performed by the repair or replacement of the defec-
tive parts, at our own discretion. The warranty does
not cover damage to wear parts, nor does it cover
damage or defects caused by improper treatment,
maintenance or the use of non-genuine parts. Further
consequential damage to other objects shall be
excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well-packed with a
brief description of the fault, a receipt or invoice (date
of purchase and dealer's stamp) to the appropriate
Service Centre.
Declaration of Conformity
This product complies with
- Low-Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- R&TTE Directive 1999/05/EC
- WEEE Directive 2012/19/EC
Note: 1 = ON / 1-6
0 = OFF / 1-6
000 Channel 1 011 Channel 5
001 Channel 2 110 Channel 6
010 Channel 3 101 Channel 7
100 Channel 4 111 Channel 8
DIP 1 – 3 (channel selection) -
DIP 4 – Communication unit (wireless)
Factory setting: DIP switch 0/OFF
9.1
9.3
9.5
9.6
9.4
Repair service:
Please ask your nearest service
centre how to proceed for repairing
faults not covered by the warranty or
occurring after the warranty expires.
GB
DIP 5 - 6 – Dimming function -
Dimensions (Ø x h) Ø 350 x 85 mm (glass)
Power supply 230 – 240 V, 50 Hz
Output 22 W LED (2.4 W when dimmed)
Luminous flux 2000 lm (without diffuser)
Efficiency 90.9 lm/W (without diffuser)
Luminous flux (with diffuser) WW PMMA 1386 lm 63 lm/W
WW PC 1000 lm 46 lm/W
WW Glass 1210 lm 55 lm/W
CW PMMA 1440 lm 66 lm/W
CW PC 1039 lm 47 lm/W
CW Glass 1257 lm 57 lm/W
Light colour RS PRO LED S2 WW: 3000 K (warm white) / RS PRO LED S2 KW: 4000 K (cold white)
HF-system 5.8 GHz (responds to the tiniest movement regardless of temperature)
Detection angle 360° detection angle with 160° angle of aperture
Transmission power approx. 1 mW
Reach 1 – 8 m all round
Max. area covered approx. 50 m²
Time setting 5 sec. – 15 min.
Twilight setting 2 – 2000 lux
Brightness control 10 % when dimmed
a) all night long
b) 10 min. after selected time elapses
c) 30 min. after selected time elapses
IP rating IP 20
IK rating PC: IK07 / PMMA: IK03 / glass: IK02
Protection class II
Temperature range -10 to +50 °C
Troubleshooting
SensorLight without power
SensorLight will not switch ON
SensorLight will not switch OFF
SensorLight switches ON without
any identifiable movement
SensorLight does not switch ON
despite movement
Malfunction
Fuse faulty in building's fuse box,
not switched ON, break in wiring
Short circuit in mains power
supply lead
Any mains switch OFF
Fit new fuse in building's fuse box,
turn mains switch ON, check power
supply lead with a voltage tester
Check connections
Switch ON mains power switch
Wrong twilight setting selected
Mains switch OFF
House fuse faulty
Adjust setting
Switch ON
Fit new fuse in building's fuse box,
check connection if necessary
Continuous movement in
detection zone
Check zone
Light not mounted for detecting
movement reliably
Movement occurred, but not identi-
fied by the sensor (movement behind
wall, movement of a small object in
immediate lamp
vicinity etc.)
Securely mount enclosure
Check zone
Rapid movements are being sup-
pressed to minimise malfunctioning
or the detection zone you have set is
too small
Check zone
Cause Remedy
Light permanently dimmed
Not working
DIM level button in Install mode DIM level button
Deactivate Install mode
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Steinel RS PRO LED S2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info