OPERATION
Cleaning, care and maintenance
20 | CK 20 Trend LCD www.stiebel-eltron.com
Note
The following applies to all time programs (Pro1, Pro2,
Pro3):
If the end time is later than 23:59h, the end time will
automatically be moved to the next day of the week. The
comfort phase is maintained past midnight and will end
on the next day at the set end time.
Time programs Pro1 and Pro2
You can specify the comfort mode start and end times with time
programsPro1 and Pro2. During this time period, the appliance
heats to the set comfort temperature. Outside this specified time
period, the appliance operates in setback mode. This results
in a comfort phase and a setback phase, which are repeated
daily(Pro1) or on every working day (Pro2).
Theses phases are factory-set as follows:
- 08:00h - 22:00h: Comfort mode
- 22:00h - 08:00h: Setback mode
Note
When time programPro2 is enabled, the appliance oper-
ates at weekends exclusively in setback mode.
To adapt time programsPro1 and Pro2 according to your needs,
proceed as follows:
In the configuration menu, use "+" and "–" to call up the re-
quired time program.
Press "OK".
The start time for comfort mode is displayed.
Use "+" and "" to set the required start time.
Press "OK".
The end time for comfort mode is displayed.
Use "+" and "" to set the required end time.
Press "OK" to save.
Time program Pro3
You can use time programPro3 to specify up to 14 separate com-
fort phases which are repeated weekly.
To configure a comfort phase in time programPro3, proceed as
follows:
In the configuration menu, use "+" and "–" to call up time
programPro3.
Press "OK".
The display shows "3---".
Press "OK".
A day of the week or a group of days is displayed.
Use "+" and "" to select the required day or group of days.
Press "OK".
The start time for comfort mode is displayed.
Use "+" and "" to set the required start time.
Press "OK".
The end time for comfort mode is displayed.
Use "+" and "" to set the required end time.
Press "OK".
Comfort phase "3-01" has been configured.
To configure a further comfort phase, use "+" and "–" in time
programPro3 to select display"3---". Proceed as describe
above.
6.3.3 Parameters
You can call up the following parameters:
Display Description Options
P1 Room temperature offset ±3°C | ±5°F
P2 Time format 12h | 24h
P3 Temperature display units °C | °F
P4 Reset time programs (timer mode). on | off
P5 Reset relative heating time on | off
To change the value of a parameter, use "+" and "–" to call up the
relevant parameter. Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with "+" and "–". Press "OK" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a dif-
ference between displayed actual temperatureI1 and the room
temperature you measure. To compensate for this difference, a
room temperature offset of ±3°C can be set via parameterP1.
Example: The appliance indicates I1=21.0°C. You have measured
a room temperature of 20.0°C. There is a difference of 1.0°C.
To compensate for the difference, select an offset of P1=-1.0.
P2: Time format
ParameterP2 allows you to specify whether the time is displayed
in the 12hour or 24hour format.
P3: Temperature display units
ParameterP3 is used to specify whether the room temperature is
displayed in degrees Centigrade [°C] or Fahrenheit [°F].
P4: Reset time programs
Activating parameterP4 resets all time programs to the factory
setting.
P5: Reset relative heating time
Activating parameterP5 resets the counter for relative heating
time (I2).
7. Cleaning, care and maintenance
The appliance contains no user serviceable parts.
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning prod-
ucts. Avoid abrasive or corrosive cleaning products.
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

stiebel-eltron-ck-20-trend-lcd

Suche zurücksetzen

  • Will das Gerät nur manuell bedienen ,wenn ich den Raum betrete einschalten und bei verlassen des Raumes ausschalten . Zudem sollte die Frostschutzfunktion bei 7 Grad automatisch einschalten Eingereicht am 8-12-2023 12:42

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stiebel Eltron CK 20 Trend LCD wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info