650328
11
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
ENGLISH
 


Push the appliance over the stud of the mounting bracket, so
that it breaks through the soft seal.
Push the fixing toggle onto the stud of the mounting bracket
that penetrates the back panel.
Press the back panel firmly into place and lock the fixing
toggle by turning it through 90°.
Push the cable grommet over the power cable. For this, use
the installation aid. For a power cable of 10 or 16 mm², the
hole in the cable grommet must be enlarged. Click the cable
grommet into place in the back panel.
10.3.4 Connecting a load shedding relay
Install the load shedding relay in conjunction with other electric
appliances, e.g. electric storage heaters. The relay responds when
the instantaneous water heater starts. The load shedding relay is
available from Stiebel Eltron as a special accessory.
Note
Connect the phase that switches the load shedding relay
to the indicated terminal of the mains terminal in the
appliance.
2
1
8502�02�0003
1 Control cable to the contactor of the second appliance (e.g.
electric storage heater).
2 Control contact, opens when switching the instantaneous
water heater on.
10.3.5 Water installation for finished walls
Suitable pressure taps WKMD or WBMD for installation on finished
walls are available as special accessories.
Fit the water plugs with gaskets to seal the connection
(below the plaster). With Stiebel Eltron pressure taps, plugs
and gaskets are part of the standard delivery. For third party
pressure taps, plugs and gaskets can be ordered as special
accessories.
Install the tap.
Push the lower part of the back panel under the connection
pipes of the pressure tap and click it into place in the back
panel.
Secure the connection pipes to the appliance.
2602�02�0528
WKMD
WBMD
10.3.6 Water installation for finished walls with solder/
compression fitting
With the special accessories "solder fitting" or "compression fitting"
(see "Accessories"), copper or plastic pipes can be connected in
installations for finished walls.
With special accessory "solder tting", a threaded connection with
on-site 12 mm copper pipes is possible. For this the following
steps are required:
Push the union nuts over the connection pipes.
Solder the inserts to the copper pipes.
Push the lower part of the back panel under the connection
pipes and click it into place in the back panel.
Secure the connection pipes to the appliance.
Note
Observe the valve manufacturer's installation instructions.
10.3.7 Water installation for finished walls, fitting the
appliance cap
The following steps are necessary to complete the appliance cap
installation.
Cleanly break out the knock-out in the appliance cap. If
necessary, use a file.
Break the tabs out of the cap guides.
Note
The appliance can be sealed by fitting the cap guides with
tabs if the tap pipes are slightly offset. The back panel
guides are not required in this case.
Click the cap guides provided into place in the knock-outs.
Position the back panel guides on the pipes and push them
together. Then push the guides until they meet the back
panel.
Secure the back panel at the bottom with a screw. This is
also relevant if flexible water supply systems are used.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stiebel Eltron DHB-E 18 SLi 25A electronic wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Stiebel Eltron DHB-E 18 SLi 25A electronic

Stiebel Eltron DHB-E 18 SLi 25A electronic Bedienungsanleitung und Installationsanweisung - Deutsch, Englisch, Holländisch, Französisch, Polnisch - 116 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info